9
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Toggle
®
Tables - Triple Motor C-Leg Height-Adjustable Square Shoe Base, Model SS
Assembly Instructions
IMPORTANT SAFETY INSTRUCTIONS
When using an electrical furnishing, basic precautions should always be followed, including
the following:
Read all instructions before using (this furnishing).
DANGER:
To reduce the risk of electric shock:
1. Always unplug this furnishing from the outlet before cleaning.
WARNING:
To reduce the risk of burns, fire, electric shock, or injury to persons:
1. Unplug from outlet before putting on or taking parts off parts.
2. Close supervision is necessary when this furnishing is used by, or near children, invalids,
or disabled persons.
3. Use this furnishing only for its intended use as described in these instructions. Do not use
attachments not recommended by the manufacturer.
4. Do not use outdoors.
5.
WARNING:
Risk of Electric Shock-Connect this furnishing to a properly grounded outlet
only. See Grounding Instructions.
SAVE THESE INSTRUCTIONS
Electrical Rating:
Input:
120V/60HZ/10A
Output:
360VA/24V
WARNING:
Risk of Injury-Do not exceed recommended operating loads. See Table
Operating Capacity Chart on
page 8.
Duty Cycle:
10% per hour. (2 minutes “ON” and 18 minutes “OFF” at continuous
operation under load.
This table is not designed for continuous operation. Table operation
must not exceed duty cycle.
Toggle Troubleshooting Guide
** Table “Zero Setting”
Press and hold the Up button for two seconds then release. Next, press and hold the Down button until table has reached its lowest position then release Down button. Then, press
the Down button again and hold for approximately 10 seconds. The table now re-set at its “Zero Setting” position and is ready to operate.
Note:
Intellect System Protection (ISP)
detection is disabled during “Zero Setting” Operation.
Warning:
In spite of Intellect System Protection (ISP) being in place, there may still be a risk of pinching in exceptional cases, as it is not only the control unit, but also the
interaction between the mechanical and electrical systems that is responsible for cutting out the motor. In addition, the mechanical components, motor and ambient conditions all
affect cut-out sensitivity. KI and the control unit manufacturer, cannot therefor eliminate this residual risk completely or accept any liability.
Symptom
Reason
Corrective Measure
Table does not move.
• Incorrect or no voltage.
• Table requires “Zero Setting”.
• One of more component connectors has come disconnected
or not fully connected.
• Damaged components or connectors.
• Table has exceeded its duty cycle.
• Verify there is power to the table. Make sure the table is properly
plugged into a functioning power source. Make sure the power cord is
fully engaged into the socket on the control box.
• Perform Table “Zero Setting” **.
• Verify all connectors are securely connected to legs and to control
box. Disconnect and re-connect each one to ensure it is properly
seated, then preform a Table “Zero Setting” **.
• Check for visible damage to all connectors and connector receptacles.
• Allow table to cool.
Table Base moves erratically
or is tilted (one leg moves,
one does not).
• Control box is not properly synchronized with the legs.
• Ensure that all cables connections are fully seated. Then perform a
Table “Zero Setting” **.
Table base stops and will
only move down (or up).
• Table may be at its highest (or lowest) position (range 26” at
the lowest to 52” at the highest) and then can only go down
(or up).
• Table or an object on the table is colliding with an obstruction.
• Table is overloaded or the weight on the table is not evenly
distributed.
• Control box is not properly synchronized with the legs.
• Press the other switch button.
• Perform a visual check and clear any obstructions.
• Reduce load and attempt to adjust the table.
• Ensure that all cable connections are fully seated. Then perform a
Table “Zero Setting” **.
All above corrective
measures have been applied
and table still does not move.
• Control Box is damaged.
• Forward the part number (P/N) off the control box label (located next
to receptacles) to your Customer Service Representative.
Table does not reach its
correct highest (52”) or
lowest (26”) position.
• Table limits may need to be programmed.
• Contact your customer service representative.