Cable diagrams
WARNING
Risk of fatal injury from electric shock
Exposed electrical components.
•
Before.installation,.make.sure.that.the.connecting.cables.are.voltage-free.
• All work on the 230 V AC mains power supply must be carried out in compliance with the current German VDE regula-
tions.(e.g.,.VDE.0100).and.any.relevant.country-specific.requirements.
9.1
IO module/IO module smart in slave mode
The IO module/IO module smart communicates digitally via the SI-BUS log with the electromechanical drive of the
KFV.multi-point.lock..The.drive.(A-opener,.GENIUS.A/B/PANIC).takes.over.the.master.functions.and.the.IO.module/
IO module smart is operated in slave mode.
Max. 3 SIEGENIA ACS and up to 7 IO modules can be integrated into a BUS system. The last slave component must
terminate.the.SI-BUS.system.via.a.termination.plug.(included.in.delivery).or.via.a.connected.top-hat.rail.power.
supply.
IO module/IO module smart with frame-integrated power supply
1
3
5
4
2
Item
Name
1
Electromechanical KFV drive (A-opener, GENIUS A, GENIUS B, GENIUS PANIC)
2
Cable transfer
3
Frame-integrated power supply
4
IO.module/IO.module.smart.(termination.via.JST.plug)
5
Inputs/outputs for external devices (e. g. intercom system)