SIEGENIA access control systems
Assembly instructions
IO module/IO module smart
05.2020
14/24
H39.ELEKS010EN-00
9.2.2
Connect cable transition to frame-integrated power supply
1
3
2
4
f
Attach.the.bushing.[1].of.the.
adapter cable of the power sup-
ply.to.the.plug.[2].of.the.cable.
transition.
f
Insert.the.green.PTR.plug.[3].of.
the adapter cable into the con-
nection.„GENIUS/A-opener.side“.
(0.to.3).of.the.power.supply.[4].
9.2.3
Connect frame-integrated power supply to IO module/IO module smart
1
3
4
7
2
6
5
f
Insert.the.green.PTR.plug.[1].
of the adapter cable into the
connection.„optional.side“.(0.to.
3).of.the.power.supply.[2].
f
Insert.the.plug.[3].of.the.adapter.
cable.on.the.bushing.[4].of.the.
extension cable and the bushing
[5].into.the.SI-BUS.connection.
[6].of.the.IO.module/IO.module.
smart.
f
Insert.the.termination.plug.[7].
into the second SI-BUS connec-
tion.[6].