Keysight N9927-90001 User’s Guide 173
SA (Spectrum Analyzer) Mode
SA Mode Settings
FFT Gating is a simple, efficient way to set the proper amount of trigger delay
and capture time so that signal artifacts of a repeating waveform or pulse can
be examined in the frequency domain. Learn more about trigger settings in
.
For best results, Auto Trigger should be used with this feature to ensure that
the sweep does not wait indefinitely for a trigger. Set Auto Trigger to a time
that is longer than the expected periodic rate of the signal. This is especially
important when using RF Burst or Video triggering in wider spans, because the
signal providing those triggers has limited bandwidth. Learn more about Auto
trigger in
“Auto Trigger Time” on page 171
.
For more conceptual information on this topic, please refer to Spectrum
Analysis Basics (App Note 150), pages 31 - 35, at
http://literature.cdn.keysight.com/litweb/pdf/5952-0292.pdf
How to set FFT Gating
— Create a non-zero span measurement. Wider frequency spans take more
time to acquire.
— Press
Sweep 3
— Then
Trigger Settings
— Then
FFT Gating Setup
— Then choose from the following:
—
Gate View OFF ON
When ON, a separate zero span measurement is
displayed below the non-zero span window. The gate view
measurement helps to configure the gate width and delay by
revealing (with green markers) the location of the gate relative to the
trigger event. The zero span measurement is tuned to the center
frequency of the non-zero span measurement with about 5 MHz of
bandwidth. The Y-axis scale is the same for both windows.
—
Gate View Time
Set the X-axis span for the non-zero span window.
Enter a value using the numeric keypad, the ?|? arrows, or the rotary
knob. This value is annotated as Swp (nn) below the window.
—
FFT Gating OFF ON
When ON, the trigger type, gate width, and delay
are applied to the non-zero span measurement. The Res BW is set to
a value that is inversely proportional to the gate width.
—
Gate Width
Set the width of the gating area within the non-zero span
window. The gating area is indicated by two vertical green lines. Enter
a value using the numeric keypad, the ?|? arrows, or the rotary knob.
—
Gate Delay
Effectively moves the gating area left (negative delay) or
right (positive delay) relative to the trigger event. Enter a value using
the numeric keypad, the
arrows, or the rotary knob.
Содержание N9913A
Страница 6: ...6 ...
Страница 56: ...56 Keysight N9927 90001 User s Guide CAT Cable and Antenna Test Mode 2 Port Insertion Loss Measurements ...
Страница 82: ...82 Keysight N9927 90001 User s Guide TDR Time Domain Reflectometry Option 215 TDR Measurement Settings ...
Страница 106: ...106 Keysight N9927 90001 User s Guide NA Network Analyzer Mode NA Mode Settings ...
Страница 142: ...142 Keysight N9927 90001 User s Guide Calibration for NA CAT and VVM Modes Calibration Method Summary ...
Страница 202: ...202 Keysight N9927 90001 User s Guide SA Spectrum Analyzer Mode Channel Measurements ...
Страница 262: ...262 Keysight N9927 90001 User s Guide IQ Analyzer IQA Option 351 CPU2 Only Other Features Available ...
Страница 286: ...286 Keysight N9927 90001 User s Guide Interference Analyzer SA Mode Option 236 Record Playback SA Option ...
Страница 292: ...292 Keysight N9927 90001 User s Guide Reflection Mode SA Models Option 320 Reflection Mode Settings ...
Страница 316: ...316 Keysight N9927 90001 User s Guide Frequency Offset Using Power Sensor FOPS Option 208 FOPS Settings ...
Страница 332: ...332 Keysight N9927 90001 User s Guide Pulse Measurements Mode Option 330 Pulse Measurement Settings ...
Страница 346: ...346 Keysight N9927 90001 User s Guide VVM Vector Voltmeter Mode Option 308 A B and B A Measurements ...
Страница 370: ...370 Keysight N9927 90001 User s Guide AM FM Metrics SA Only and Option 355 Interpreting AM FM Metrics Error Messages ...
Страница 444: ...444 Keysight N9927 90001 User s Guide Noise Figure Mode Option 356 CPU2 Only Troubleshooting ...
Страница 470: ...Data Analysis Features All about Scale Settings 470 Keysight N9927 90001 User s Guide ...
Страница 528: ...528 Keysight N9927 90001 User s Guide Working with the Lithium Ion Battery Lithium Ion Battery Disposal ...
Страница 544: ...544 Keysight N9927 90001 User s Guide Safety Considerations Certification and Compliance Statements ...
Страница 546: ...546 Keysight N9927 90001 User s Guide Connector Care Review ...
Страница 548: ...548 Keysight N9927 90001 User s Guide Connector Care Review ...
Страница 550: ...550 Keysight N9927 90001 User s Guide Specifications Data Sheet ...
Страница 553: ...553 Keysight Handheld Analyzers N99xxA User s Guide D Korean Battery Safety Translation ...
Страница 554: ...554 Keysight N9927 90001 User s Guide Korean Battery Safety Translation ...
Страница 555: ...555 Keysight Handheld Analyzers N99xxA User s Guide E Keysight Software End User Licensing Agreement EULA ...
Страница 556: ...556 Keysight N9927 90001 User s Guide Keysight Software End User Licensing Agreement EULA ...
Страница 557: ...Keysight N9927 90001 User s Guide 557 Keysight Software End User Licensing Agreement EULA ...
Страница 558: ...558 Keysight N9927 90001 User s Guide Keysight Software End User Licensing Agreement EULA ...
Страница 565: ......