background image

Notices

© Keysight Technologies, Inc. 

2009-2019

No part of this manual may be 

reproduced in any form or by any 

means (including electronic storage 

and retrieval or translation into a 

foreign language) without prior 

agreement and written consent from 

Keysight Technologies, Inc. as 

governed by United States and 

international copyright laws.

Trademark Acknowledgments

Manual Part Number

N5225-90107

Edition

Edition 2, June 2019

 

Supersedes: July 2017

Printed in USA/Malaysia

Published by:

Keysight Technologies

1400 Fountaingrove Parkway 

Santa Rosa, CA 95403

Warranty

THE MATERIAL CONTAINED IN THIS 

DOCUMENT IS PROVIDED “AS IS,” 

AND IS SUBJECT TO BEING 

CHANGED, WITHOUT NOTICE, IN 

FUTURE EDITIONS. FURTHER, TO 

THE MAXIMUM EXTENT PERMITTED 

BY APPLICABLE LAW, KEYSIGHT 

DISCLAIMS ALL WARRANTIES, 

EITHER EXPRESS OR IMPLIED WITH 

REGARD TO THIS MANUAL AND 

ANY INFORMATION CONTAINED 

HEREIN, INCLUDING BUT NOT 

LIMITED TO THE IMPLIED 

WARRANTIES OF 

MERCHANTABILITY AND FITNESS 

FOR A PARTICULAR PURPOSE. 

KEYSIGHT SHALL NOT BE LIABLE 

FOR ERRORS OR FOR INCIDENTAL 

OR CONSEQUENTIAL DAMAGES IN 

CONNECTION WITH THE 

FURNISHING, USE, OR 

PERFORMANCE OF THIS 

DOCUMENT OR ANY INFORMATION 

CONTAINED HEREIN. SHOULD 

KEYSIGHT AND THE USER HAVE A 

SEPARATE WRITTEN AGREEMENT 

WITH WARRANTY TERMS 

COVERING THE MATERIAL IN THIS 

DOCUMENT THAT CONFLICT WITH 

THESE TERMS, THE WARRANTY 

TERMS IN THE SEPARATE 

AGREEMENT WILL CONTROL.

Technology Licenses

The hardware and/or software 

described in this document are 

furnished under a license and may be 

used or copied only in accordance 

with the terms of such license.

U.S. Government Rights

The Software is “commercial 

computer software,” as defined 

by Federal Acquisition Regulation 

(“FAR”) 2.101. Pursuant to FAR 

12.212 and 27.405-3 and 

Department of Defense FAR 

Supplement (“DFARS”) 227.7202, 

the U.S. government acquires 

commercial computer software 

under the same terms by which 

the software is customarily 

provided to the public. 

Accordingly, Keysight provides 

the Software to U.S. government 

customers under its standard 

commercial license, which is 

embodied in its End User License 

Agreement (EULA), a copy of 

which can be found at 

http://www.keysight.com/find/sweula

The license set forth in the EULA 

represents the exclusive authority 

by which the U.S. government 

may use, modify, distribute, or 

disclose the Software. The EULA 

and the license set forth therein, 

does not require or permit, 

among other things, that 

Keysight: (1) Furnish technical 

information related to 

commercial computer software 

or commercial computer 

software documentation that is 

not customarily provided to the 

public; or (2) Relinquish to, or 

otherwise provide, the 

government rights in excess of 

these rights customarily provided 

to the public to use, modify, 

reproduce, release, perform, 

display, or disclose commercial 

computer software or 

commercial computer software 

documentation. No additional 

government requirements 

beyond those set forth in the 

EULA shall apply, except to the 

extent that those terms, rights, or 

licenses are explicitly required 

from all providers of commercial 

computer software pursuant to 

the FAR and the DFARS and are 

set forth specifically in writing 

elsewhere in the EULA. Keysight 

shall be under no obligation to 

update, revise or otherwise 

modify the Software. With 

respect to any technical data as 

defined by FAR 2.101, pursuant 

to FAR 12.211 and 27.404.2 and 

DFARS 227.7102, the U.S. 

government acquires no greater 

than Limited Rights as defined in 

FAR 27.401 or DFAR 227.7103-5 

(c), as applicable in any technical 

data.

Safety Notices

CAUTION

 notice denotes a hazard. It 

calls attention to an operating 

procedure, practice, or the like that, 

if not correctly performed or adhered 

to, could result in damage to the 

product or loss of important data. Do 

not proceed beyond a CAUTION 

notice until the indicated conditions 

are fully understood and met. 

WARNING

 notice denotes a hazard. 

It calls attention to an operating 

procedure, practice, or the like that, 

if not correctly performed or adhered 

to, could result in personal injury or 

death. Do not proceed beyond a 

WARNING notice until the indicated 

conditions are fully understood and 
met.

Содержание N5225-60107

Страница 1: ...A B Option 401 to Option 417 or PNA X N5244A B or N5245A B Option 401 to Option 417 For Analyzers with Serial Numbers Prefixed MY SG US5150 and Below Upgrade Kit Order Numbers N5224AU 417 N5225AU 417...

Страница 2: ...ftware to U S government customers under its standard commercial license which is embodied in its End User License Agreement EULA a copy of which can be found at http www keysight com find sweula The...

Страница 3: ...ont panel overlay replacement new cables After installation of this upgrade your analyzer will be an N5224A B Option 417 or N5225A B Option 417 or N5244B Option 417 or N5245B Option 417 Some of the as...

Страница 4: ...ght com find assist If you do not have access to the Internet please contact your Keysight field engineer If You Have Problems With the Upgrade Kit Contents Keysight stands behind the quality of the u...

Страница 5: ...ols Required for the Installation on page 6 Enough time refer to About Installing the Upgrade on page 6 Test equipment for the post upgrade adjustments and full instrument calibration To view the equi...

Страница 6: ...NA To find your new HostID go to http www na support keysight com pna upgrades html and using the HostID utility enter the PNA serial number and your new upgraded PNA X model number N5224A N5225A N524...

Страница 7: ...ssistance Refer to Getting Assistance from Keysight on page 3 Downloading the Online PNA Service Guide To view the online Service Guide for your PNA model number use the following steps 1 Go to www ke...

Страница 8: ...bs 2 38 N m 1 N A 5 16 in 8 mm nutsetter or open end torque wrench set to 10 in lbs 1 13 N m 1 N A Use a 5 16 in torque wrench set to 10 in lbs on all cable connections Products affected N5224A B N522...

Страница 9: ...wer Front panel overlay PNA B models N5224 5B 1 N5225 80006 Lower Front panel overlays PNA X models N5244 5B 1 N5242 80031 Machine screw M3 x 8 pan head to attach brackets to attenuators to attach por...

Страница 10: ...3 receiver attenuator to A28 mixer brick C 1 N5245 20066 W101 RF cable front panel Port 4 RCVR D IN to A48 port 4 receiver attenuator 1 N5245 20074 W102 RF cable A48 port 4 receiver attenuator to A28...

Страница 11: ...Assemblies Step 8 Assemble the Source Attenuator Assemblies Step 9 Install the Source Attenuator Assemblies Step 10 Install Some Bottom Side Test Set Cables Step 11 Remove the Old Lower Front Panel Ov...

Страница 12: ...ter Cover For instructions click the Chapter 7 bookmark Removing the Covers in the PDF Service Guide Step 3 Remove Some Bottom Side Test Set Cables 1 Place the analyzer bottom side up on a flat surfac...

Страница 13: ...st port 2 receiver coupler to front panel Port 2 SOURCE OUT W33 N5245 20108 A32 port 2 receiver coupler to front panel REF 2 SOURCE OUT W37 N5245 20041 Front panel Port 1 RCVR A IN to A27 mixer brick...

Страница 14: ...r this step of the procedure New parts are listed in Table 1 on page 7 Use a T 10 TORX driver to tighten all screws Figure 1 Port 1 and Port 2 Receiver Attenuator and Bracket Assembly Step 5 Install t...

Страница 15: ...the Upgrade Figure 2 Port 1 and Port 2 Receiver Attenuator Assemblies Installation Step 6 Assemble the Port 3 and Port 4 Receiver Attenuator Assemblies Refer to Figure 3 for this step of the procedure...

Страница 16: ...r the Upgrade Figure 3 Port 3 and Port 4 Receiver Attenuator and Bracket Assembly Step 7 Install the Port 3 and Port 4 Receiver Attenuator Assemblies Refer to Figure 4 for this step of the procedure N...

Страница 17: ...Installation Note N5225 90107 15 Description of the Upgrade Installation Procedure for the Upgrade Figure 4 Port 3 and Port 4 Receiver Attenuator Assemblies Installation...

Страница 18: ...lation Procedure for the Upgrade Step 8 Assemble the Source Attenuator Assemblies Refer to Figure 5 for this step of the procedure New parts are listed in Table 1 on page 7 Use a T 10 TORX driver to t...

Страница 19: ...llation Procedure for the Upgrade Step 9 Install the Source Attenuator Assemblies Refer to Figure 6 for this step of the procedure New parts are listed in Table 1 on page 7 Use a T 10 TORX driver to t...

Страница 20: ...rvice Guide1 New parts are listed in Table 1 on page 7 Install the following new cables in the order listed W103 N5245 20055 Port 2 RCVR B IN to A49 port 2 receiver attenuator W94 N5245 20031 A41 port...

Страница 21: ...A27 mixer brick R2 W101 N5245 20074 Port 4 RCVR D IN to A48 port 4 receiver attenuator W45 reuse N5245 20021 REF 4 RCVR R4 IN to 3 dB pad on A28 mixer brick R4 W90 N5245 20028 A40 port 4 source attenu...

Страница 22: ...31 port 4 receiver coupler to A40 port 4 source attenuator W99 N5245 20073 Port 3 RCVR C IN to A47 port 3 receiver attenuator W86 N5245 20027 A39 port 3 source attenuator to front panel Port 3 SOURCE...

Страница 23: ...o W13 W16 reuse N5245 20044 A31 port 4 receiver coupler to W15 W97 N5245 20054 Front panel Port 1 RCVR A IN to A46 port 1 receiver attenuator W82 N5245 20077 A38 port 1 source attenuator to front pane...

Страница 24: ...029 A32 port 2 receiver coupler to A41 port 2 source attenuator Install the Ribbon Cables To see an image showing the location of these cables click the Chapter 6 bookmarks Bottom Ribbon Cables and Wi...

Страница 25: ...test set motherboard J546 N5245 60026 A46 port 1 receiver step attenuator to A23 test set motherboard J205 N5245 60026 A47 port 3 receiver step attenuator to A23 test set motherboard J206 N5245 60007...

Страница 26: ...e front panel use a blunt object in the cutouts in the lower front dress panel to push on the old overlay item and separate it from the front dress panel 2 From the front side of the front panel pull...

Страница 27: ...Installation Note N5225 90107 25 Description of the Upgrade Installation Procedure for the Upgrade Figure 11 Lower Front Panel Overlay Replacement...

Страница 28: ...item 2 Starting from either side loosely place the overlay in the recess on the lower front panel ensuring that it fits tightly against the edges of the recess 3 Once the overlay is in place press it...

Страница 29: ...enable utility press UTILITY then then An option enable dialog box will appear 2 Click the arrow in the Select Desired Option box A list of available options will appear 3 In the Select Desired Option...

Страница 30: ...Option Enable Procedure for B Model Instruments on page 29 Option Enable Procedure for A Model Instruments 1 To start the option enable utility press UTILITY then then An option enable dialog box will...

Страница 31: ...For these steps refer to the example in Figure 12 on page 30 a Verify your USB flash drive is connected to a PC b Open your license file using a text read write program similar to Notepad c If you hav...

Страница 32: ...e Else load the license key file s manually move your license file s to C Program Files Agilent licensing It may take Keysight License Manager an extra 5 seconds to enable the licenses 5 Disconnect th...

Страница 33: ...ain adjustment receiver characterization receiver adjustment IF Response adjustment For A model Options 090 093 or 094 Only For B models Options S93090xA B S93093A B or S93094A B Only Noise adjustment...

Страница 34: ...you experience difficulty with the basic functioning of the analyzer contact Keysight Refer to Contacting Keysight on page 2 Calibration Although the analyzer functions its performance relative to it...

Страница 35: ...20 Prepare the PNA for the User 1 If necessary reinstall front jumper cables 2 Install the cable guards pushing them over the front jumper cables until the cushioning material touches the front panel...

Страница 36: ...This information is subject to change without notice Keysight Technologies 2011 2019 Edition 2 June 2019 N5225 90107 www keysight com...

Отзывы: