Step 1. Select maximum frequency range (required option)

Description

Option number

Additional information

Frequency range, 10 Hz to 3.6 GHz

N9010A-503

Frequency range, 10 Hz to 7 GHz

N9010A-507

Frequency range, 10 Hz to 13.6 GHz

N9010A-513

Frequency range, 10 Hz to 26.5 GHz N9010A-526
Frequency range, 10 Hz to 32 GHz

N9010A-532

Frequency range, 10 Hz to 44 GHz

N9010A-544

Step 2. Add a preamplifier

Description

Option number

Additional information  

Preamplifiers improve the noise floor for low-level signal detection

Preamplifier, 100 kHz to 3.6 GHz

N9010A-P03

Compatible with frequency range options N9010A-503, N9010A-507, N9010A-513, 
N9010A-526, N9010A-532, and N9010A-544

Preamplifier, 100 kHz to 7 GHz 

N9010A-P07

Compatible with frequency range options N9010A-507, N9010A-513, N9010A-526, 
N9010A-532, and N9010A-544

Preamplifier, 100 kHz to 13.6 GHz

N9010A-P13

Compatible with frequency range options N9010A-513, N9010A-526

Preamplifier, 100 kHz to 26.5 GHz

N9010A-P26

Compatible with frequency range option N9010A-526

Preamplifier, 100 kHz to 32 GHz

N9010A-P32

Compatible with frequency range option N9010A-532

Preamplifier, 100 kHz to 44 GHz

N9010A-P44

Compatible with frequency range option N9010A-544

Step 3. Choose frequency reference

Description

Option number

Additional information

Frequency reference

Standard

Aging rate: ± 1 x 10

–6

/year

Precision frequency reference  
10 MHz

N9010A-PFR 

Reduces frequency drift for more accurate measurements; aging rate: ± 1 x 10

–7

/year

Step 4. Choose an attenuator

Description

Option number

Additional information

Mechanical attenuator

Standard

10 dB steps, 0 to 60 dB

Fine step attenuator

N9010A-FSA

Allows 2 dB steps for the full 60 dB range of the mechanical attenuator

Electronic attenuator up to 3.6 GHz

N9010A-EA3

In addition to the mechanical attenuator; 1 dB steps, 0 to 24 dB

Configure Your Keysight N9010A EXA Signal Analyzer

This step-by-step process will help you configure your new N9010A EXA X-Series signal analyzer as well as add millimeter-wave 
capabilities. Tailor the performance to meet your requirements. For detailed specifications, refer to the specification guide (N9010-
90025). For a summary of specifications, refer to the data sheet (5989-6529EN).

Included in base product

Standard options and accessories come with the EXA base model at no additional charge and do not need to be ordered. They include:

 

Spectrum analyzer measurement application

 

Dual-core, high-performance processor, 8 GB RAM, removable solid-state drive

 

Frequency reference

 

Mechanical attenuator

 

10 MHz/25 MHz analysis bandwidth

 

Enhanced phase noise

 

Windows Embedded Standard 7

 

Real-time link

 

Benchtop configuration

 

Mouse

 

User guide

 

Front-panel protective cover

 

Power cord

 

3-year return-to-Keysight warranty

Содержание EXA X-Series N9010A

Страница 1: ...gnal Analyzer N9010A Configuration Guide This EXA configuration guide will help you determine which performance options measurement applications accessories and services to include with your new EXA or to add as upgrades to an existing EXA ...

Страница 2: ...ence Description Option number Additional information Frequency reference Standard Aging rate 1 x 10 6 year Precision frequency reference 10 MHz N9010A PFR Reduces frequency drift for more accurate measurements aging rate 1 x 10 7 year Step 4 Choose an attenuator Description Option number Additional information Mechanical attenuator Standard 10 dB steps 0 to 60 dB Fine step attenuator N9010A FSA A...

Страница 3: ... with CISPR 16 1 1 detectors and bandwidths tune and listen and measure at marker are also available External source control N9010A ESC External source control for Keysight EXG MXG and PSG signal generators for scalar stimu lus response measurements supports external mixing includes 3 BNC cables and 1 crossover LAN cable External mixing N9010A EXM Provides external mixing with Keysight and third p...

Страница 4: ...0B 2FP 2TP LTE LTE Advanced TDD N9082B 1FP N9082B 1TP Standard based one button LTE TDD measurements requires W7X Windows 7 OS N9082B 2FP N9082B 2TP Standard based one button LTE Advanced TDD measurements requires W7X and N9082B 1FP 1TP Multi standard radio MSR N9083A 1FP N9083A 1TP Standard based one button MSR measurements on any combination of LTE FDD W CDMA HSPA HSPA GSM EDGE EDGE Evo cdma2000...

Страница 5: ...ut production not compatible with Options 532 or 544 requires Option B40 N9077A 6FP N9077A 6TP Standard based one button 802 11ah measurement requires firmware above version A 16 05 N9077A 7FP N9077A 7TP Standard based one button 802 11af measurement requires firmware above version A 18 01 Bluetooth N9081A 2FP N9081A 2TP Standard based one button Bluetooth version 2 1 EDR and Low Energy LE measure...

Страница 6: ...time gating AM FM PM demodulation statistical measure ments also supports Option EXM N9064A 2FP N9064A 2TP Adds flexible digital modulation analysis general purpose digital modulation for 2 16FSK 2 8PSK and 16 1024QAM as well as more than 15 additional formats requires 1FP 1TP EMC N6141A 2FP N6141A 2TP Pre compliance conducted and radiated emission measurements MATLAB software N6171A M01 Not avail...

Страница 7: ...n Option number Additional information Bench top configuration Standard Provides two side carrying straps four rear feet and four bottom feet with a tilt stand a front panel protective cover is included Portable configuration N9010A PRC Provides a convenient pivoting carrying handle as well as rubber protective corners and end guards this configuration is intended for applications requiring more r...

Страница 8: ...put return loss 20 and 11 dB Insertion loss 5 7 dB V Band waveguide harmonic mixers 50 to 75 GHz M1970V 001 Requires Option EXM USB mixer with smart features Extended V band waveguide harmonic mixers 50 to 80 GHz M1970V 002 Requires Option EXM USB mixer with smart features E Band waveguide harmonic mixers 60 to 90 GHz M1970E Requires Option EXM USB mixer with smart features W Band waveguide harmon...

Страница 9: ...ension module N9029AV05 VDI signal analyzer frequency extension module requires Option EXM 220 to 330 GHz frequency extension module N9029AV03 VDI signal analyzer frequency extension module requires Option EXM 325 to 500 GHz frequency extension module N9029AV02 VDI signal analyzer frequency extension module requires Option EXM 550 to 750 GHz frequency extension module N9029AV1B VDI signal analyzer...

Страница 10: ...redited cal N9010A AMG Provides ISO 17025A accredited calibration from factory ANSI Z540 1 1994 Calibration N9010A A6J Provides ANSI Z540 compliant calibration from factory Calibration Assurance Plan Return to Keysight 3 years R 50C 011 3 Keysight tests your instrument against its original specifications and automatically makes adjustments if outside of specified parameters pre and post adjustment...

Страница 11: ... HL7 532 or 544 Serial prefix US SG MY5648 Includes hardware and license key also adds microwave preselector bypass not compatible with Options 503 507 513 or 526 N9010AK HLF 532 or 544 Serial prefix US SG MY5648 Increase analysis bandwidth to 40 MHz Option 503 only N9010AK HL8 503 Serial prefix US SG MY5648 Includes hardware and license key only compatible with Option 503 N9010AK HL9 503 Serial p...

Страница 12: ... capability N9020AK TDS N6141A and DP2 or B40 For EMC pre compliance tests only Add Y axis screen video output N9010AK YAS None Upgrade to multi touch user interface Multi touch user interface N9010AK MTU PC6 or PC7 Not all applications supported by N9010A with standard user interface UI are supported with multi touch UI Multi touch user interface with processor N9010AK MTP None Upgrade to dual co...

Страница 13: ... R RW drive N9010AK DVR None Electronic attenuator 3 6 GHz N9010AK EA3 None Fine step attenuator N9010AK FSA None Hard transit case N9010AK HTC None Keyboard USB interface N9010AK KYB None Enhances the usability of the Windows Professional operation system Note Does not fit N9010A BAG accessory pouch US 65 key USB keyboard N9010AK KB2 None Compact design fits in N9010A BAG accessory pouch for conv...

Страница 14: ...r unique combination of hardware software support and people can help you reach your next breakthrough We are unlocking the future of technology From Hewlett Packard to Agilent to Keysight For more information on Keysight Technologies products applications or services please contact your local Keysight office The complete list is available at www keysight com find contactus Americas Canada 877 894...

Отзывы: