background image

06 | Keysight | N9010A EXA X-Series Signal Analyzer - Configuration Guide

Step 11. Choose measurement application or software and license type, continued

Description

Fixed license

Transportable license Additional information

General purpose
Spectrum analyzer

Standard

Not available

Traditional spectrum analysis plus many new and enhanced functions; power 

measurements based on industry specifications

Analog 
demodulation 

N9063A-2FP

N9063A-2TP

Adds one-button measurement for AM/FM/PM demodulation with metrics, 
audio analysis, and tune-and-listen AF spectrum; supports analog output

N9063A-3FP

N9063A-3TP

Adds FM Stereo and RDS; requires 2FP/2TP

Phase noise 

N9068A-2FP

N9068A-2TP

Adds one-button measurements for analyzing phase noise in frequency 
domain (log plot) and time domain (spot frequency)

Noise figure

N9069A-1FP

(requires preamplifier 
to meet specifications)

N9069A-1TP

(requires preamplifier 
to meet specifications)

Adds one-button measurements for noise figure, gain, and related metrics; 
requires preamplifier to meet specifications; works with Keysight N400xA 

Series smart noise sources and 346 Series noise sources; supports 

U7227-Series USB Preamplifier

N9069A-2FP

N9069A-2TP

Advanced NF measurement features including external LO control over GPIB/
LAN/USB,  and manual mode to simulate the legacy NF meter; requires 
1FP/1TP

VXA vector signal 
analysis

N9064A-1FP

N9064A-1TP

Vector signal analysis; high-resolution, FFT-based spectrum and time-domain 
measurements, time gating, AM/FM/PM demodulation, statistical measure-
ments; also supports Option EXM

N9064A-2FP

N9064A-2TP

Adds flexible digital modulation analysis; general purpose digital modulation 

for 2-16FSK, 2-8PSK, and 16-1024QAM, as well as more than 15 additional 
formats; requires 1FP/1TP

EMC

N6141A-2FP

N6141A-2TP

Pre-compliance conducted and radiated emission measurements

MATLAB software

N6171A-M01

Not available

Instrument Control Toolbox

N6171A-M02

Not available

Instrument Control Toolbox 
Communications System Toolbox 
DSP System Toolbox 
Signal Processing Toolbox

N6171A-M03

Not available

Instrument Control Toolbox 
Communications System Toolbox 
DSP System Toolbox 
Signal Processing Toolbox 
RF Toolbox

Pulse 

N9051B-2FP

N9051B-2TP

Enables basic magnitude-vs-time analysis

N9051B-3FP

N9051B-3TP

Adds phase and frequency measurements; requires 2FP/2TP

N9051B-4FP

N9051B-4TP

Adds extended analysis and statistics; requires 2FP/2TP

N9051B-5FP

N9051B-5TP

Extends capture depth to 50 MSa; requires 2FP/2TP

SCPI command 
language 
compatibility 

N9062A-2FP

Not available

Adds capability to emulate the R&S FSP/FSU/FSE spectrum analyzers

Remote language 
compatibility

N9061A-1FP

Not available

Adds capability to emulate the 8566/68 spectrum analyzers

N9061A-2FP

Not available

Adds capability to emulate the 856xE/EC spectrum analyzers

89600 VSA software

Not available

89601B
(transportable license 
is standard)

Industry-leading measurement software for evaluating and troubleshooting 
signals in R&D; PC-based software supporting more than 40 measurement 
platforms, plus more than 75 signal standards and modulation types including 
MIMO analysis; 

www.keysight.com/find/89600vsa

Содержание EXA X-Series N9010A

Страница 1: ...gnal Analyzer N9010A Configuration Guide This EXA configuration guide will help you determine which performance options measurement applications accessories and services to include with your new EXA or to add as upgrades to an existing EXA ...

Страница 2: ...ence Description Option number Additional information Frequency reference Standard Aging rate 1 x 10 6 year Precision frequency reference 10 MHz N9010A PFR Reduces frequency drift for more accurate measurements aging rate 1 x 10 7 year Step 4 Choose an attenuator Description Option number Additional information Mechanical attenuator Standard 10 dB steps 0 to 60 dB Fine step attenuator N9010A FSA A...

Страница 3: ... with CISPR 16 1 1 detectors and bandwidths tune and listen and measure at marker are also available External source control N9010A ESC External source control for Keysight EXG MXG and PSG signal generators for scalar stimu lus response measurements supports external mixing includes 3 BNC cables and 1 crossover LAN cable External mixing N9010A EXM Provides external mixing with Keysight and third p...

Страница 4: ...0B 2FP 2TP LTE LTE Advanced TDD N9082B 1FP N9082B 1TP Standard based one button LTE TDD measurements requires W7X Windows 7 OS N9082B 2FP N9082B 2TP Standard based one button LTE Advanced TDD measurements requires W7X and N9082B 1FP 1TP Multi standard radio MSR N9083A 1FP N9083A 1TP Standard based one button MSR measurements on any combination of LTE FDD W CDMA HSPA HSPA GSM EDGE EDGE Evo cdma2000...

Страница 5: ...ut production not compatible with Options 532 or 544 requires Option B40 N9077A 6FP N9077A 6TP Standard based one button 802 11ah measurement requires firmware above version A 16 05 N9077A 7FP N9077A 7TP Standard based one button 802 11af measurement requires firmware above version A 18 01 Bluetooth N9081A 2FP N9081A 2TP Standard based one button Bluetooth version 2 1 EDR and Low Energy LE measure...

Страница 6: ...time gating AM FM PM demodulation statistical measure ments also supports Option EXM N9064A 2FP N9064A 2TP Adds flexible digital modulation analysis general purpose digital modulation for 2 16FSK 2 8PSK and 16 1024QAM as well as more than 15 additional formats requires 1FP 1TP EMC N6141A 2FP N6141A 2TP Pre compliance conducted and radiated emission measurements MATLAB software N6171A M01 Not avail...

Страница 7: ...n Option number Additional information Bench top configuration Standard Provides two side carrying straps four rear feet and four bottom feet with a tilt stand a front panel protective cover is included Portable configuration N9010A PRC Provides a convenient pivoting carrying handle as well as rubber protective corners and end guards this configuration is intended for applications requiring more r...

Страница 8: ...put return loss 20 and 11 dB Insertion loss 5 7 dB V Band waveguide harmonic mixers 50 to 75 GHz M1970V 001 Requires Option EXM USB mixer with smart features Extended V band waveguide harmonic mixers 50 to 80 GHz M1970V 002 Requires Option EXM USB mixer with smart features E Band waveguide harmonic mixers 60 to 90 GHz M1970E Requires Option EXM USB mixer with smart features W Band waveguide harmon...

Страница 9: ...ension module N9029AV05 VDI signal analyzer frequency extension module requires Option EXM 220 to 330 GHz frequency extension module N9029AV03 VDI signal analyzer frequency extension module requires Option EXM 325 to 500 GHz frequency extension module N9029AV02 VDI signal analyzer frequency extension module requires Option EXM 550 to 750 GHz frequency extension module N9029AV1B VDI signal analyzer...

Страница 10: ...redited cal N9010A AMG Provides ISO 17025A accredited calibration from factory ANSI Z540 1 1994 Calibration N9010A A6J Provides ANSI Z540 compliant calibration from factory Calibration Assurance Plan Return to Keysight 3 years R 50C 011 3 Keysight tests your instrument against its original specifications and automatically makes adjustments if outside of specified parameters pre and post adjustment...

Страница 11: ... HL7 532 or 544 Serial prefix US SG MY5648 Includes hardware and license key also adds microwave preselector bypass not compatible with Options 503 507 513 or 526 N9010AK HLF 532 or 544 Serial prefix US SG MY5648 Increase analysis bandwidth to 40 MHz Option 503 only N9010AK HL8 503 Serial prefix US SG MY5648 Includes hardware and license key only compatible with Option 503 N9010AK HL9 503 Serial p...

Страница 12: ... capability N9020AK TDS N6141A and DP2 or B40 For EMC pre compliance tests only Add Y axis screen video output N9010AK YAS None Upgrade to multi touch user interface Multi touch user interface N9010AK MTU PC6 or PC7 Not all applications supported by N9010A with standard user interface UI are supported with multi touch UI Multi touch user interface with processor N9010AK MTP None Upgrade to dual co...

Страница 13: ... R RW drive N9010AK DVR None Electronic attenuator 3 6 GHz N9010AK EA3 None Fine step attenuator N9010AK FSA None Hard transit case N9010AK HTC None Keyboard USB interface N9010AK KYB None Enhances the usability of the Windows Professional operation system Note Does not fit N9010A BAG accessory pouch US 65 key USB keyboard N9010AK KB2 None Compact design fits in N9010A BAG accessory pouch for conv...

Страница 14: ...r unique combination of hardware software support and people can help you reach your next breakthrough We are unlocking the future of technology From Hewlett Packard to Agilent to Keysight For more information on Keysight Technologies products applications or services please contact your local Keysight office The complete list is available at www keysight com find contactus Americas Canada 877 894...

Отзывы: