Keysight EXA X-Series N9010A Скачать руководство пользователя страница 11

11 | Keysight | N9010A EXA X-Series Signal Analyzer - Configuration Guide

Description

Upgrade 
number

Requirements  
(EXA must already  
include the following)

Additional information

Increase frequency from 3.6 to 7 GHz,

N9010AK-F01

503

Increase frequency from 3.6 to 13.6 GHz

N9010AK-F02

503

Increase frequency from 3.6 to 26.5 GHz

N9010AK-F03

503

Increase frequency from 3.6 to 32 GHz

N9010AK-F04

503

Requires serial number  ≥ MY/SG/US52180000 

Increase frequency from 3.6 to 44 GHz

N9010AK-F05

503

Requires serial number  ≥ MY/SG/US52180000

Increase frequency from 7 to 13.6 GHz

N9010AK-F06

507

Increase frequency from 7 to 26.5 GHz

N9010AK-F07

507

Increase frequency from 7 to 32 GHz

N9010AK-F08

507

Requires serial number  ≥ MY/SG/US52180000

Increase frequency from 7 to 44 GHz

N9010AK-F09

507

Requires serial number  ≥ MY/SG/US52180000

Increase frequency from 13.6 to 26.5 GHz

N9010AK-F10

513

Increase frequency from 13.6 to 32 GHz

N9010AK-F11

513

Requires serial number  ≥ MY/SG/US52180000

Increase frequency from 13.6 to 44 GHz

N9010AK-F12

513

Requires serial number  ≥ MY/SG/US52180000

Increase frequency from 26.5 to 32 GHz

N9010AK-F13

526

Requires serial number  ≥ MY/SG/US52180000

Increase frequency from 26.5 to 44 GHz

N9010AK-F14

526

Requires serial number  ≥ MY/SG/US52180000

Increase frequency from 32 to 44 GHz

N9010AK-F15

532

Includes 44 GHz preamp

Increase analysis bandwidth from 10 to 25 MHz

N9010AK-B25 

3

None

Increase analysis bandwidth from 10 to 40 MHz

N9010AK-B40

DP2 or MPB

Increase analysis bandwidth from 25 to 40 MHz

N9010AK-BU1

B25 and DP2 or MPB

Increase analysis bandwidth to 40 MHz. Includes 

microwave preselector bypass. Options 507, 513, 

and 526 only.

N9010AK-HL4

507, 513, or 526

Serial prefix < US/SG/MY5648

Includes hardware and license key; also adds 

microwave preselector bypass; not compatible 

with Option 503, 532 or 544

N9010AK-HLA

507, 513, or 526

Serial prefix ≥ US/SG/MY5648

Increase analysis bandwidth to 40 MHz. Includes 

microwave preselector bypass. Options 532 and 

544 only.

N9010AK-HL7

532 or 544

Serial prefix < US/SG/MY5648 

Includes hardware and license key; also adds 

microwave preselector bypass; not compatible 

with Options 503, 507, 513, or 526

N9010AK-HLF

532 or 544

Serial prefix ≥ US/SG/MY5648

Increase analysis bandwidth to 40 MHz, 

Option 503 only.

N9010AK-HL8

503

Serial prefix < US/SG/MY5648

Includes hardware and license key; only 

compatible with Option 503

N9010AK-HL9

503

Serial prefix ≥ US/SG/MY5648

1.  At the time of manufacture, the hardware related to many of these options was fully adjusted and the option performance was verified to be within its 

warranted specifications. Within two years of the initial calibration date of the analyzer, this option is fully calibrated with no further adjustment or 

verification testing.

2.  If this analyzer has been adjusted as part of a repair or calibration during its first two years, or if the analyzer is more than two years old, additional 

adjustment and performance verification tests are required to ensure that some newly installed options are functioning properly. However, the completion 

of these tests does not guarantee that the analyzer meets all warranted specifications.

3.  This upgrade option is for instruments ordered before May 1, 2011.

Instrument Upgrades

Fast license-key upgrades for performance options that do not require additional 
hardware:

1.  Place an order for the upgrade with Keysight and request to receive the option 

upgrade entitlement certificate and a one-time software upgrade license through 
email

2.   Redeem the certificate through the Web by following the instructions on the 

certificate

3.  Install the license file and latest software in the EXA
4.  Begin using the new capability 

1, 2

Installation and testing information is available at: 

www.keysight.com/find/exa_upgrades

Upgrades for analysis bandwidth depend on the vintage of the instrument and the 
options already installed. More than one option may be required to achieve desired wider 
analysis bandwidth. Use our web-based calculator to find the upgrade options you may 
need: 

www.keysight.com/find/BW-selector 

You can upgrade! 

Options can be 
added after your 
initial purchase. 

All of our X-Series 
application options 

 

are license-key upgradeable.

Содержание EXA X-Series N9010A

Страница 1: ...gnal Analyzer N9010A Configuration Guide This EXA configuration guide will help you determine which performance options measurement applications accessories and services to include with your new EXA or to add as upgrades to an existing EXA ...

Страница 2: ...ence Description Option number Additional information Frequency reference Standard Aging rate 1 x 10 6 year Precision frequency reference 10 MHz N9010A PFR Reduces frequency drift for more accurate measurements aging rate 1 x 10 7 year Step 4 Choose an attenuator Description Option number Additional information Mechanical attenuator Standard 10 dB steps 0 to 60 dB Fine step attenuator N9010A FSA A...

Страница 3: ... with CISPR 16 1 1 detectors and bandwidths tune and listen and measure at marker are also available External source control N9010A ESC External source control for Keysight EXG MXG and PSG signal generators for scalar stimu lus response measurements supports external mixing includes 3 BNC cables and 1 crossover LAN cable External mixing N9010A EXM Provides external mixing with Keysight and third p...

Страница 4: ...0B 2FP 2TP LTE LTE Advanced TDD N9082B 1FP N9082B 1TP Standard based one button LTE TDD measurements requires W7X Windows 7 OS N9082B 2FP N9082B 2TP Standard based one button LTE Advanced TDD measurements requires W7X and N9082B 1FP 1TP Multi standard radio MSR N9083A 1FP N9083A 1TP Standard based one button MSR measurements on any combination of LTE FDD W CDMA HSPA HSPA GSM EDGE EDGE Evo cdma2000...

Страница 5: ...ut production not compatible with Options 532 or 544 requires Option B40 N9077A 6FP N9077A 6TP Standard based one button 802 11ah measurement requires firmware above version A 16 05 N9077A 7FP N9077A 7TP Standard based one button 802 11af measurement requires firmware above version A 18 01 Bluetooth N9081A 2FP N9081A 2TP Standard based one button Bluetooth version 2 1 EDR and Low Energy LE measure...

Страница 6: ...time gating AM FM PM demodulation statistical measure ments also supports Option EXM N9064A 2FP N9064A 2TP Adds flexible digital modulation analysis general purpose digital modulation for 2 16FSK 2 8PSK and 16 1024QAM as well as more than 15 additional formats requires 1FP 1TP EMC N6141A 2FP N6141A 2TP Pre compliance conducted and radiated emission measurements MATLAB software N6171A M01 Not avail...

Страница 7: ...n Option number Additional information Bench top configuration Standard Provides two side carrying straps four rear feet and four bottom feet with a tilt stand a front panel protective cover is included Portable configuration N9010A PRC Provides a convenient pivoting carrying handle as well as rubber protective corners and end guards this configuration is intended for applications requiring more r...

Страница 8: ...put return loss 20 and 11 dB Insertion loss 5 7 dB V Band waveguide harmonic mixers 50 to 75 GHz M1970V 001 Requires Option EXM USB mixer with smart features Extended V band waveguide harmonic mixers 50 to 80 GHz M1970V 002 Requires Option EXM USB mixer with smart features E Band waveguide harmonic mixers 60 to 90 GHz M1970E Requires Option EXM USB mixer with smart features W Band waveguide harmon...

Страница 9: ...ension module N9029AV05 VDI signal analyzer frequency extension module requires Option EXM 220 to 330 GHz frequency extension module N9029AV03 VDI signal analyzer frequency extension module requires Option EXM 325 to 500 GHz frequency extension module N9029AV02 VDI signal analyzer frequency extension module requires Option EXM 550 to 750 GHz frequency extension module N9029AV1B VDI signal analyzer...

Страница 10: ...redited cal N9010A AMG Provides ISO 17025A accredited calibration from factory ANSI Z540 1 1994 Calibration N9010A A6J Provides ANSI Z540 compliant calibration from factory Calibration Assurance Plan Return to Keysight 3 years R 50C 011 3 Keysight tests your instrument against its original specifications and automatically makes adjustments if outside of specified parameters pre and post adjustment...

Страница 11: ... HL7 532 or 544 Serial prefix US SG MY5648 Includes hardware and license key also adds microwave preselector bypass not compatible with Options 503 507 513 or 526 N9010AK HLF 532 or 544 Serial prefix US SG MY5648 Increase analysis bandwidth to 40 MHz Option 503 only N9010AK HL8 503 Serial prefix US SG MY5648 Includes hardware and license key only compatible with Option 503 N9010AK HL9 503 Serial p...

Страница 12: ... capability N9020AK TDS N6141A and DP2 or B40 For EMC pre compliance tests only Add Y axis screen video output N9010AK YAS None Upgrade to multi touch user interface Multi touch user interface N9010AK MTU PC6 or PC7 Not all applications supported by N9010A with standard user interface UI are supported with multi touch UI Multi touch user interface with processor N9010AK MTP None Upgrade to dual co...

Страница 13: ... R RW drive N9010AK DVR None Electronic attenuator 3 6 GHz N9010AK EA3 None Fine step attenuator N9010AK FSA None Hard transit case N9010AK HTC None Keyboard USB interface N9010AK KYB None Enhances the usability of the Windows Professional operation system Note Does not fit N9010A BAG accessory pouch US 65 key USB keyboard N9010AK KB2 None Compact design fits in N9010A BAG accessory pouch for conv...

Страница 14: ...r unique combination of hardware software support and people can help you reach your next breakthrough We are unlocking the future of technology From Hewlett Packard to Agilent to Keysight For more information on Keysight Technologies products applications or services please contact your local Keysight office The complete list is available at www keysight com find contactus Americas Canada 877 894...

Отзывы: