ACQuire:CCDF:DURation <numeric_value>
This command sets the CCDF trigger duration.
Syntax
Parameter
Example
ACQ
:CCDF
Space
?
:DUR
numeric_value
Item
Description/Default
Range of values
numeric_value
A numeric value in second for the CCDF trigger duration:
– Default value: 10 ms
– Minimum value: 100 ns
– Maximum value: 1 s
The value specified will be truncated to a multiple of 10 ns.
The range of values above is determined by CCDF trigger duration
×
CCDF
frame and must be
≤
100 s.
100 ns to 1 s
ACQ:CCDF:DUR 0.01
This command sets the CCDF trigger duration to
0.01 s.
Содержание 8990B
Страница 1: ...Keysight 8990B Peak Power Analyzer Programming Guide ...
Страница 16: ...16 Keysight 8990B Programming Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 18: ...18 Keysight 8990B Programming Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 20: ...20 Keysight 8990B Programming Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 46: ...1 8990B Remote Operation 46 Keysight 8990B Programming Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 142: ...4 ACQuire Subsystem 142 Keysight 8990B Programming Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 156: ...5 CALibration Subsystem 156 Keysight 8990B Programming Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 188: ...6 CHANnel Subsystem 188 Keysight 8990B Programming Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 450: ...15 STATus Subsystem 450 Keysight 8990B Programming Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 460: ...16 DISPlay Subsystem 460 Keysight 8990B Programming Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 508: ...20 WMEMory Subsystem 508 Keysight 8990B Programming Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 518: ...21 SERVice Subsystem 518 Keysight 8990B Programming Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...