background image

Keysight M9451A PXIe Measurement Accelerator

26

Step 6 - Installation Complete

Proceed to program your product by means of the applications programming 
interface (API) for the supplied drivers.

API Overview

IVI Drivers

Keysight's IVI drivers simplify the creation and maintenance of instrument control 
applications in a variety of development environments; they allow programmatic 
control of instrumentation while providing a greater degree of instrument 
interchangeability and code reuse. IVI drivers currently come in two basic types: IVI-
COM and IVI-C. Although the functionality offered by both types of drivers is often 
very similar, the fundamental differences in interface technology results in a very 
different end-user experience. The IVI drivers support compiling application 
programs for 32- or 64-bit platforms.

Supported ADEs (application development environments) Arguably the most 
important consideration in comparing IVI-COM and IVI-C drivers is the end user 
experience in various ADEs. Since IVI-COM drivers are based on Microsoft COM 
technology, it's not surprising that IVI-COM drivers offer the richest user experience 
in Microsoft ADEs. Users working in Visual C++, Visual C#, Visual Basic.NET, and 
Visual Basic 6 enjoy a host of features, such as object browsers, IntelliSense, and 
context-sensitive help.

When you install the product software, the IVI driver files are installed in the 
standard IVI Foundation directories (for example, <Your Drive:>\Program Files (x86)
\IVI Foundation\IVI\Drivers). Example programs are provided to demonstrate most 
driver functionality (for example,<Your Drive:>\Program Files (x86)\IVI 
Foundation\IVI\Drivers\KtMMAcc). The reference material for the driver functions 
(a Microsoft HTML Help .chm file) is installed with the IVI driver and is available for 
Microsoft Visual Studio's IntelliSense context linking. In addition, you can directly 
access the .chm file (KtMMAcc.chm) from this Start menu location: 

 > 

Start

All 

 > 

 > 

.

Programs

Keysight

MMAcc

Содержание M9451A

Страница 1: ...Keysight M9451A PXIe Measurement Accelerator Startup guide...

Страница 2: ...are under the same terms by which the software is customarily provided to the public Accordingly Keysight provides the Software to U S government customers under its standard commercial license which...

Страница 3: ...often associated with local AC mains connections Assume all measurement control and data I O connections are for connection to Category I sources unless otherwise marked or described in the user docu...

Страница 4: ...the Canadian Interference Causing Equipment Standard ICES 001 It also identifies the product is an Industrial Scientific and Medical Group 1 Class A product CISPR 11 Clause 4 South Korean Class A EMC...

Страница 5: ...ments 16 Chassis Requirements 17 M9018A Chassis Air Flow 17 Power up the Controller 18 Software Installation Overview 18 Software Installation Procedure 19 Step 4 Install the Module 20 Module Installa...

Страница 6: ...Keysight M9451A PXIe Measurement Accelerator 6...

Страница 7: ...Keysight M9451A PXIe Measurement Accelerator 7 Documentation Access...

Страница 8: ...amplifiers PAs and front end modules FEMs Hardware acceleration provides speed improvement over Keysight s previous host based Reference Solution with closed open loop digital pre distortion DPD and...

Страница 9: ...e is designed to work with the Keysight s RF PA FEM Characterization Test Reference Solution and allows you to perform fast DPD ET measurements with hardware that supports peer to peer transfers For m...

Страница 10: ...ocumentation To access documentation related to the Keysight M9451A PXIe Measurement Accelerator use one of the following methods If the product software is installed on your PC the related documents...

Страница 11: ...ns as well as information to help you get started with using the IVI drivers in your application development environment Your Drive Program Files x86 IVI Foundation IVI Drivers KtMMAcc KtMMAcc chm CHM...

Страница 12: ...asurement Accelerator 12 To find the very latest versions of the user documentation go to the product web site and download the files from the www keysight com find m9451a Manuals support page go to D...

Страница 13: ...wrist strap combination and conductive floor mat and heel strap combination Both types when used together provide a significant level of ESD protection Of the two only the table mat and wrist strap co...

Страница 14: ...h it to the malfunctioning equipment Name and address of owner A P O box is not acceptable as a return address Module serial number s The serial number label is located on the side panel of the module...

Страница 15: ...rs this functionality through propriety APIs and does not allow the customer to reprogram the FPGA with a custom image Items included in your Shipment Qty Keysight Part Number Description 1 M9451A Key...

Страница 16: ...ble hard disk space includes 1 GB available for Microsoft NET Framework 3 5 SP1 100 MB for Keysight IO Libraries Suite Video Support for DirectX 9 graphics with 128 MB graphics memory recommended Supe...

Страница 17: ...perable or forced air cooling is obstructed Use slot blockers Keysight model 5 per kit and EMC filler panels in Y1212A empty module slots to ensure proper operating temperatures Keysight chassis and s...

Страница 18: ...e chassis The Keysight M9036A PXIe Embedded Controller and Keysight M9018A PXIe Chassis are recommended Please refer to the embedded controller and chassis documentation for further details Connect pe...

Страница 19: ...you to choose either a complete or custom setup to install Choose the features to install and click Next Follow the guided tour to complete the installation Click Next After the installation complete...

Страница 20: ...n speed settings ensure that the fan switch is set appropriately for the system Default setting is AUTO fan speed and the inhibit set to DEF Position the chassis to provide ample space between the cha...

Страница 21: ...is Secure the module to the chassis using the module mounting screws Use a 1 Pozidriv or a slotted screwdriver and torque to 5 Lb In 0 57 N m Performance may suffer if the screws are not tightened pro...

Страница 22: ...sing an external host PC If all the modules and their slot locations are not visible in the Connect to Instrument dialog of SFP program Close the SFP Start Keysight Connection Expert by selecting Star...

Страница 23: ...en the M9451A SFP by selecting Start All Programs Keysight MMAcc MMAcc SFP Select the M9451A module in the dialog and Connect to Instrument click to initialize the instrument Connect Check the front p...

Страница 24: ...Accelerator the LED starts in the OFF state and then changes to green after a few moments when PXI enumeration has taken place Generally when the LED status is solid green or solid blue it means that...

Страница 25: ...LED color Description Blue blinking The accelerator is processing data or a self test is running Yellow solid An error or self test failure occurred Red solid Error condition Analog power supply shut...

Страница 26: ...the most important consideration in comparing IVI COM and IVI C drivers is the end user experience in various ADEs Since IVI COM drivers are based on Microsoft COM technology it s not surprising that...

Страница 27: ...r further troubleshooting information Contact a Keysight Technologies Service Center Computer Verify that the equipment meets the minimum requirements Refer Software Requirements Refer to the computer...

Страница 28: ...ted User A user with Administrator status can reset the permissions of a Restricted User to enable that user to run the software The following steps outline the procedure In Windows Explorer navigate...

Страница 29: ...This information is subject to change without notice Keysight Technologies 2013 2015 Edition 1 1 July 2015 Printed In Malaysia M9451 90001 M9451 90001 www keysight com...

Отзывы: