background image

Notices

Copyright Notices

© Keysight Technologies 2013 - 2015

No part of this manual may be reproduced 
in any form or by any means (including 
electronic storage and retrieval or 
translation into a foreign language) 
without prior agreement and written 
consent from Keysight Technologies,Inc. 
as governed by United States and 
international copyright laws.

Manual Part Number

M9451-90001

Published By

Keysight Technologies Ground Floor and 
Second Floor, CP-11 Sector-8, IMT 
Manesar – 122051 Gurgaon, Haryana, 
India

Edition

Edition 1.1, July, 2015

Printed In

Malaysia

Regulatory Compliance

This product has been designed and 
tested in accordance with accepted 
industry standards, and has been supplied 
in a safe condition. To review the 
Declaration of Conformity, go to 

http://www.keysight.com/go/conformity

Warranty

THE MATERIAL CONTAINED IN THIS 
DOCUMENT IS PROVIDED "AS IS," AND 
IS SUBJECT TO BEING CHANGED, 
WITHOUT NOTICE, IN FUTURE EDITIONS.
FURTHER, TO THE MAXIMUM EXTENT 
PERMITTED BY APPLICABLE LAW, 
KEYSIGHT DISCLAIMS ALL WARRANTIES, 
EITHER EXPRESS OR IMPLIED, WITH 
REGARD TO THIS MANUAL AND ANY 
INFORMATION CONTAINED HEREIN, 
INCLUDING BUT NOT LIMITED TO THE 
IMPLIED WARRANTIES OF MERCHANT 
ABILITY AND FITNESS FOR A 
PARTICULAR PURPOSE. KEYSIGHT 
SHALL NOT BE LIABLE FOR ERRORS OR 
FOR INCIDENTAL OR CONSEQUENTIAL 
DAMAGES IN CONNECTION WITH THE

FURNISHING, USE, OR PERFORMANCE OF 
THIS DOCUMENT OR OF ANY 
INFORMATION CONTAINED HEREIN. 
SHOULD KEYSIGHT AND THE USER HAVE A 
SEPARATE WRITTEN AGREEMENT WITH 
WARRANTY TERMS COVERING THE 
MATERIAL IN THIS DOCUMENT THAT 
CONFLICT WITH THESE TERMS, THE 
WARRANTY TERMS IN THE SEPARATE 
AGREEMENT SHALL CONTROL.

KEYSIGHT TECHNOLOGIES DOES NOT 
WARRANT THIRD-PARTY SYSTEMLEVEL 
(COMBINATION OF CHASSIS, 
CONTROLLERS, MODULES, ETC.) 
PERFORMANCE, SAFETY, OR REGULATORY 
COMPLIANCE, UNLESS SPECIFICALLY 
STATED.

Technology Licenses

The hardware and/or software described in 
this document are furnished under a license 
and may be used or copied only in 
accordance with the terms of such license.

U.S. Government Rights

The Software is “commercial computer 
software,” as defined by Federal Acquisition 
Regulation (“FAR”) 2.101. Pursuant to FAR 
12.212 and 27.405-3 and Department of 
Defense FAR Supplement (“DFARS”) 
227.7202, the U.S. government acquires 
commercial computer software under the 
same terms by which the software is 
customarily provided to the public. 
Accordingly, Keysight provides the Software 
to U.S. government customers under its 
standard commercial license, which is 
embodied in its End User License Agreement 
(EULA), a copy of which can be found at 
http://www.keysight.com/find/sweula. The 
license set forth in the EULA represents the 
exclusive authority by which the U.S. 
government may use, modify, distribute, or 
disclose the Software. The EULA and the 
license set forth therein, does not require or 
permit, among other things, that Keysight: 
(1) Furnish technical information related to 
commercial computer software or 
commercial computer software 
documentation that is not customarily 
provided to the public; or (2) Relinquish

to, or otherwise provide, the government 
rights in excess of these rights customarily 
provided to the public to use, modify, 
reproduce, release, perform, display, or 
disclose commercial computer software or 
commercial computer software 
documentation. No additional government 
requirements beyond those set forth in 
the EULA shall apply, except to the extent 
that those terms, rights, or licenses are 
explicitly required from all providers of 
commercial computer software pursuant 
to the FAR and the DFARS and are set 
forth specifically in writing elsewhere in 
the EULA. Keysight shall be under no 
obligation to update, revise or otherwise 
modify the Software. With respect to any 
technical data as defined by FAR 2.101, 
pursuant to FAR 12.211 and 27.404.2 and 
DFARS 227.7102, the U.S. government 
acquires no greater than Limited Rights as 
defined in FAR 27.401 or DFAR 227.7103-
5 (c), as applicable in any technical data.

Safety Notices

A CAUTION notice denotes a hazard. It 
calls attention to an operating procedure, 
practice, or the like that, if not correctly 
performed or adhered to, could result in 
damage to the product or loss of 
important data. Do not proceed beyond a 
CAUTION notice until the indicated 
conditions are fully understood and met.

A WARNING notice denotes a hazard. It 
calls attention to an operating procedure, 
practice, or the like that, if not correctly 
performed or adhered to, could result in 
personal injury or death. Do not proceed 
beyond a WARNING notice until the 
indicated conditions are fully understood 
and met.

The following safety precautions should 
be observed before using this product and 
any associated instrumentation. This 
product is intended for use by qualified 
personnel who recognize

Содержание M9451A

Страница 1: ...Keysight M9451A PXIe Measurement Accelerator Startup guide...

Страница 2: ...are under the same terms by which the software is customarily provided to the public Accordingly Keysight provides the Software to U S government customers under its standard commercial license which...

Страница 3: ...often associated with local AC mains connections Assume all measurement control and data I O connections are for connection to Category I sources unless otherwise marked or described in the user docu...

Страница 4: ...the Canadian Interference Causing Equipment Standard ICES 001 It also identifies the product is an Industrial Scientific and Medical Group 1 Class A product CISPR 11 Clause 4 South Korean Class A EMC...

Страница 5: ...ments 16 Chassis Requirements 17 M9018A Chassis Air Flow 17 Power up the Controller 18 Software Installation Overview 18 Software Installation Procedure 19 Step 4 Install the Module 20 Module Installa...

Страница 6: ...Keysight M9451A PXIe Measurement Accelerator 6...

Страница 7: ...Keysight M9451A PXIe Measurement Accelerator 7 Documentation Access...

Страница 8: ...amplifiers PAs and front end modules FEMs Hardware acceleration provides speed improvement over Keysight s previous host based Reference Solution with closed open loop digital pre distortion DPD and...

Страница 9: ...e is designed to work with the Keysight s RF PA FEM Characterization Test Reference Solution and allows you to perform fast DPD ET measurements with hardware that supports peer to peer transfers For m...

Страница 10: ...ocumentation To access documentation related to the Keysight M9451A PXIe Measurement Accelerator use one of the following methods If the product software is installed on your PC the related documents...

Страница 11: ...ns as well as information to help you get started with using the IVI drivers in your application development environment Your Drive Program Files x86 IVI Foundation IVI Drivers KtMMAcc KtMMAcc chm CHM...

Страница 12: ...asurement Accelerator 12 To find the very latest versions of the user documentation go to the product web site and download the files from the www keysight com find m9451a Manuals support page go to D...

Страница 13: ...wrist strap combination and conductive floor mat and heel strap combination Both types when used together provide a significant level of ESD protection Of the two only the table mat and wrist strap co...

Страница 14: ...h it to the malfunctioning equipment Name and address of owner A P O box is not acceptable as a return address Module serial number s The serial number label is located on the side panel of the module...

Страница 15: ...rs this functionality through propriety APIs and does not allow the customer to reprogram the FPGA with a custom image Items included in your Shipment Qty Keysight Part Number Description 1 M9451A Key...

Страница 16: ...ble hard disk space includes 1 GB available for Microsoft NET Framework 3 5 SP1 100 MB for Keysight IO Libraries Suite Video Support for DirectX 9 graphics with 128 MB graphics memory recommended Supe...

Страница 17: ...perable or forced air cooling is obstructed Use slot blockers Keysight model 5 per kit and EMC filler panels in Y1212A empty module slots to ensure proper operating temperatures Keysight chassis and s...

Страница 18: ...e chassis The Keysight M9036A PXIe Embedded Controller and Keysight M9018A PXIe Chassis are recommended Please refer to the embedded controller and chassis documentation for further details Connect pe...

Страница 19: ...you to choose either a complete or custom setup to install Choose the features to install and click Next Follow the guided tour to complete the installation Click Next After the installation complete...

Страница 20: ...n speed settings ensure that the fan switch is set appropriately for the system Default setting is AUTO fan speed and the inhibit set to DEF Position the chassis to provide ample space between the cha...

Страница 21: ...is Secure the module to the chassis using the module mounting screws Use a 1 Pozidriv or a slotted screwdriver and torque to 5 Lb In 0 57 N m Performance may suffer if the screws are not tightened pro...

Страница 22: ...sing an external host PC If all the modules and their slot locations are not visible in the Connect to Instrument dialog of SFP program Close the SFP Start Keysight Connection Expert by selecting Star...

Страница 23: ...en the M9451A SFP by selecting Start All Programs Keysight MMAcc MMAcc SFP Select the M9451A module in the dialog and Connect to Instrument click to initialize the instrument Connect Check the front p...

Страница 24: ...Accelerator the LED starts in the OFF state and then changes to green after a few moments when PXI enumeration has taken place Generally when the LED status is solid green or solid blue it means that...

Страница 25: ...LED color Description Blue blinking The accelerator is processing data or a self test is running Yellow solid An error or self test failure occurred Red solid Error condition Analog power supply shut...

Страница 26: ...the most important consideration in comparing IVI COM and IVI C drivers is the end user experience in various ADEs Since IVI COM drivers are based on Microsoft COM technology it s not surprising that...

Страница 27: ...r further troubleshooting information Contact a Keysight Technologies Service Center Computer Verify that the equipment meets the minimum requirements Refer Software Requirements Refer to the computer...

Страница 28: ...ted User A user with Administrator status can reset the permissions of a Restricted User to enable that user to run the software The following steps outline the procedure In Windows Explorer navigate...

Страница 29: ...This information is subject to change without notice Keysight Technologies 2013 2015 Edition 1 1 July 2015 Printed In Malaysia M9451 90001 M9451 90001 www keysight com...

Отзывы: