safety issues. When the modules are in use
and operation within the specified full tem-
perature range is not maintained, module
surface temperatures may exceed safe hand-
ling conditions which can cause discomfort
or burns if touched. In the event of a module
exceeding the full temperature range,
always allow the module to cool before
touching or removing modules from chassis.

Keysight products are designed for use with
electrical signals that are rated Meas-
urement Category I and Measurement Cat-
egory II, as described in the International
Electrotechnical Commission (IEC) Standard
IEC 60664. Most measurement, control,
and data I/O signals are Measurement Cat-
egory I and must not be directly connected
to mains voltage or to voltage sources with
high transient over-voltages. Measurement
Category II connections require protection
for high transient over-voltages often asso-
ciated with local AC mains connections.
Assume all measurement, control, and data
I/O connections are for connection to Cat-
egory I sources unless otherwise marked or
described in the user documentation.

Exercise extreme caution when a shock hazard
is present. Lethal voltage may be present on
cable connector jacks or test fixtures. The
American National Standards Institute (ANSI)
states that a shock hazard exists when voltage
levels greater than 30V RMS, 42.4V peak, or
60VDC are present. A good safety practice is to
expect that hazardous voltage is present in any
unknown circuit before measuring.

Operators of this product must be protected
from electric shock at all times. The respons-
ible body must ensure that operators are pre-
vented access and/or insulated from every
connection point. In some cases, connections
must be exposed to potential human contact.
Product operators in these circumstances
must be trained to protect themselves from
the risk of electric shock. If the circuit is cap-
able of operating at or above 1000V, no con-
ductive part of the circuit may be exposed.

Do not connect switching cards directly to
unlimited power circuits. They are intended to
be used with impedance-limited sources.
NEVER connect switching cards directly to AC

mains. When connecting sources to switching
cards, install protective devices to limit fault
current and voltage to the card.

Before operating an instrument, ensure that
the line cord is connected to a properly-groun-
ded power receptacle. Inspect the connecting
cables, test leads, and jumpers for possible
wear, cracks, or breaks before each use.

When installing equipment where access to
the main power cord is restricted, such as rack
mounting, a separate main input power dis-
connect device must be provided in close prox-
imity to the equipment and within easy reach
of the operator.

For maximum safety, do not touch the
product, test cables, or any other instruments
while power is applied to the circuit under
test. ALWAYS remove power from the entire
test system and discharge any capacitors
before: connecting or disconnecting cables or
jumpers, installing or removing switching
cards, or making internal changes, such as
installing or removing jumpers.

Do not touch any object that could provide a
current path to the common side of the circuit
under test or power line (earth) ground.
Always make measurements with dry hands
while standing on a dry, insulated surface cap-
able of withstanding the voltage being meas-
ured.

The instrument and accessories must be used
in accordance with its specifications and oper-
ating instructions, or the safety of the equip-
ment may be impaired.

Do not exceed the maximum signal levels of
the instruments and accessories, as defined in
the specifications and operating information,
and as shown on the instrument or test fixture
panels, or switching card.

When fuses are used in a product, replace with
the same type and rating for continued pro-
tection against fire hazard.

Chassis connections must only be used as
shield connections for measuring circuits, NOT
as safety earth ground connections.

If you are using a test fixture, keep the lid
closed while power is applied to the device
under test. Safe operation requires the use of a
lid interlock.

A

CAUTION

notice denotes a hazard. It calls

attention to an operating procedure, practice,

or the like that, if not correctly performed or
adhered to, could result in damage to the
product or loss of important data. Do not pro-
ceed beyond a

CAUTION

notice until the indic-

ated conditions are fully understood and met.

A WARNING notice denotes a hazard. It
calls attention to an operating procedure,
practice, or the like that, if not correctly per-
formed or adhered to, could result in per-
sonal injury or death. Do not proceed beyond
a WARNING notice until the indicated con-
ditions are fully understood and met.

Instrumentation and accessories shall not be
connected to humans.

Before performing any maintenance, dis-
connect the line cord and all test cables.

To maintain protection from electric shock and
fire, replacement components in mains circuits
– including the power transformer, test leads,
and input jacks – must be purchased from Key-
sight. Standard fuses with applicable national
safety approvals may be used if the rating and
type are the same. Other components that are
not safety-related may be purchased from
other suppliers as long as they are equivalent
to the original component (note that selected
parts should be purchased only through Key-
sight to maintain accuracy and functionality of
the product). If you are unsure about the
applicability of a replacement component, call
an Keysight office for information.

No operator serviceable parts inside. Refer
servicing to qualified personnel. To prevent
electrical shock do not remove covers. For
continued protection against fire hazard,
replace fuse with same type and rating.
PRODUCT MARKINGS:

The CE mark is a registered trademark of the
European Community.

Australian Communication and Media Author-
ity mark to indicate regulatory compliance as a
registered supplier.

Содержание LTE

Страница 1: ...anced Multi Channel Reference Solution Notice This document contains references to Agilent Please note that Agilent s Test and Measurement busi ness has become Keysight Technologies For more informati...

Страница 2: ......

Страница 3: ...DFAR 252 227 7014 June 1995 or as a com mercial item as defined in FAR 2 101 a or as Restricted computer software as defined in FAR 52 227 19 June 1987 or any equivalent agency regulation or contract...

Страница 4: ...from the entire test system and discharge any capacitors before connecting or disconnecting cables or jumpers installing or removing switching cards or making internal changes such as installing or r...

Страница 5: ...ed Protect the circuits from ESD damage by wearing a grounding strap that provides a high res istance path to ground Alternatively ground yourself to discharge any built up static charge by touching t...

Страница 6: ......

Страница 7: ...w 15 MIMO Instrument Connections 17 Recommended MIMO Configurations 18 Sharing the M9300A Frequency Reference 20 2x2 MIMO Configuration in a Single PXIe Chassis 22 3x3 MIMO Configuration in Two PXIe C...

Страница 8: ......

Страница 9: ...technique using the backplane of the PXIe chassis Refer to the Keysight M9391A PXIe Vector Signal Analyzer and M9381A PXIe Vector Signal Gen erator Programming Guide for details The scope of this doc...

Страница 10: ...Depending upon your particular order you may find the following product documentation useful Keysight Multiple PXIe and AXIe Chassis System Configuration Tool Download and save this CHM file from www...

Страница 11: ...volts Inspect for Damage After unpacking a solution inspect all components for any shipping damage Report any damage to the ship ping agent immediately as such damage is not covered by the warranty s...

Страница 12: ...shipped in multiple boxes Refer to the box content list attached to each box Step 3 Install the Modules PXI hardware does not support hot swap changing modules while power is applied to the chassis c...

Страница 13: ...M9018A has multiple air intakes They are located at the lower sides lower front and bottom of the chassis If Your Solution Contains a Keysight M9021A Cable Interface Module For greater detail on confi...

Страница 14: ...supply those voltages to the connector The default position of the switch is to the left and does not supply the voltages to the connector To use the M9021A in Slot 1 of the M9018A chassis you must m...

Страница 15: ...k the mounting screws out to ensure that there is no interference between the screws and the mounting rails 5 Refer to MIMO Instrument Connections page 17 for M9381A and M9391A cabling For MIMO config...

Страница 16: ...A male Connect this adapter to the RF Out connector of each M9310A and torque to 8 Lb In 0 904 Nm This will extend the life of often used connector 10 Cable the system according to the information on...

Страница 17: ...e coaxial SMB female SMB female 8120 5091 M9310A 100 MHz Out to M9311A 100 MHz In Cable coaxial SMB female SMB female 8120 5091 M9310A Trig 1 to M9311A Trig 1 for Pulse Mod Cable coaxial SMB female SM...

Страница 18: ...onfiguration in Two PXIe Chassis with External Controller page 23 The next configuration consists of three receivers M9391A in a single M9018A Chassis with or without an M9036A M9037A PXIe Embedded Co...

Страница 19: ...ingle chassis See the 3x3 or 4x4 configurations for module placements within a single chassis Placing the M9391A VSAs recommendation Install the M9391A VSA instruments in the chassis with the Keysight...

Страница 20: ...ed before use so including it in all configurations allows applications to be started in any order However when sharing a module the user interface of some applications may not reflect M9300A settings...

Страница 21: ...ed to the reference module in a shared default mode and you try to connect a second instance of the SFP to the same reference with ShareRe ferenceVisaSession 0 Advanced Option you will get the resourc...

Страница 22: ...ut 1 to M9301A 100 MHz In slot 5 l 100 MHz Out 2 to M9301A 100 MHz In slot 7 l 100 MHz Out 3 to M9301A 100 MHz In slot 11 l 100 MHz Out 4 to M9301A 100 MHz In slot 18 2x2 MIMO Configuration with Exter...

Страница 23: ...ut 1 to M9301A 100 MHz In slot 9 l 100 MHz Out 2 to M9301A 100 MHz In slot 14 l 100 MHz Out 3 to M9301A 100 MHz In slot 5 For the second bottom configuration master From the M9300A slot 10 use three 8...

Страница 24: ...ut 1 to M9301A 100 MHz In slot 9 l 100 MHz Out 2 to M9301A 100 MHz In slot 14 l 100 MHz Out 3 to M9301A 100 MHz In slot 5 For the second bottom configuration master From the M9300A slot 10 use three 8...

Страница 25: ...ut 1 to M9301A 100 MHz In slot 9 l 100 MHz Out 2 to M9301A 100 MHz In slot 14 l 100 MHz Out 3 to M9301A 100 MHz In slot 5 l 100 MHz Out 4 to M9301A 100 MHz In slot 18 For the second bottom configurati...

Страница 26: ...Step 3 Install the Modules These configurations can be used for x4 source only or analyzer only configurations 26 LTE LTE A Multi Channel Reference Solution...

Страница 27: ...z Out 2 to M9301A 100 MHz In slot 14 l 100 MHz Out 3 to M9301A 100 MHz In slot 5 l 100 MHz Out 4 to M9301A 100 MHz In slot 4 For the second bottom configuration master From the M9300A slot 10 use four...

Страница 28: ...m slot link configuration l Run one of the operating systems listed in System Requirements above Remote con troller Keysight M9018A chassis only A PC running one of the operating systems listed in Sys...

Страница 29: ...s Suite version 16 3 update 2 version 16 3 16603 3 or newer includes Keysight Connection Expert www keysight com find iosuite 2 M9018A 18 Slot PXIe Chassis Drivers www keysight com find M9018A 3 Keysi...

Страница 30: ...computer for controlling multiple PXIe chassis If you are using a desktop PC as your controller connect to the M9021A using the following components 5 Power up Your Solution If you are using a remote...

Страница 31: ...perability In this section you will run the Keysight MIMO Configuration Utility that you installed in Step 4 See 2 Install the Software page 29 After installing the files on the Keysight MIMO Accessor...

Страница 32: ...instrument for repair To ensure that you send in the group of modules that was reported in a Self Test failure open the SFP and go to Utilities Calibration Options to view this screen The string point...

Страница 33: ...river files are installed in the standard IVI Foundation dir ectories for example C Program Files IVI Foundation IVI Drivers AgM9391 Example programs are provided to demonstrate most driver functional...

Страница 34: ......

Отзывы: