Keysight UXR-Series and MXR/EXR-Series MultiScope Hardware Configuration Guide

5

Next Steps

 

Use MultiScope Control Software

After the MultiScope system hardware has been configured and you have 

performed each oscilloscope’s calibration procedure, you can use MultiScope 

control software to make data acquisitions. Your options are:
• Infiniium oscilloscope software on the Leader oscilloscope. MultiScope 

software is included as a standard feature.

• D9010BSEO Infiniium Offline oscilloscope analysis software on an external host 

computer. MultiScope software is included as a standard feature.

Infiniium Oscilloscope Software on the Leader Oscilloscope

With Infiniium oscilloscope software version 10.20 and higher, the MultiScope 

hosted instruments capability is available from within an Infiniium UXR-Series 

oscilloscope (in the box) as well as from the Infiniium Offline software running on a 

PC. Connecting to and controlling multiple oscilloscopes from within an Infiniium 

oscilloscope has the following advantages:
• You have the full triggering capability of the Infiniium oscilloscope, including 

InfiniiScan. (From the Infiniium Offline software, you have only edge and glitch 

trigger modes.)

• No additional computer is required to run the Infiniium Offline software.
• No space for an additional computer is necessary.

MultiScope software is included as a standard feature.

When using Infiniium oscilloscope software on the Leader oscilloscope, you must 

set up remote connections to the Follower oscilloscopes using the Keysight 

Connection Expert (which is part of the Keysight IO Libraries Suite).

D9010BSEO Infiniium Offline Oscilloscope Analysis Software

The D9010BSEO Infiniium Offline oscilloscope analysis software lets you identify 

oscilloscopes in a MultiScope system, perform time-correlation calibration 

(including channel deskew, see 

“UXR-Series MultiScope Calibration 

Connections"

on page 28), capture data, view waveforms, and perform analysis.

When using Infiniium Offline software on the host computer, you must set up 

remote connections to the Leader and Follower oscilloscopes using the Keysight 

Connection Expert (which is part of the Keysight IO Libraries Suite).

Host Computer Requirements

For the D9010BSEO Infiniium Offline oscilloscope analysis software, Keysight 

recommends a host computer with:
• A Windows 10 64-bit operating system with at least 8 GBytes of RAM and 

25 GBytes of hard drive space.

Содержание EXR Series

Страница 1: ...Keysight UXR Series and MXR EXR Series MultiScope Hardware Configuration Guide...

Страница 2: ...nd at www keysight com find sweula The license set forth in the EULA represents the exclusive authority by which the U S government may use modify distribute or disclose the Software The EULA and the...

Страница 3: ...ssories containing the necessary cables adapters and power dividers are required N2164A UXR Series Multi Frame Base Kit First Two Frames N2165A UXR Series Multi Frame Expansion Kit Add One Frame The N...

Страница 4: ...n an external host computer MultiScope software is included as a standard feature This software allows time synchronized acquisitions for multiple oscilloscope systems with very low oscilloscope to os...

Страница 5: ...Included MultiScope systems also require Equipment rack s Rackmount kits for the oscilloscopes MXR2RACK for MXR Series or EXR2RACK for EXR Series MultiScope control software Remote interface connecti...

Страница 6: ...the MultiScope system see Chapter 5 Next Steps starting on page 27 See Also The Infiniium UXR Series oscilloscope software s online help for information on using the MultiScope Hosted Instruments soft...

Страница 7: ...es 14 3 Three to Five Oscilloscope Systems UXR Series Expansion Equipment Required 18 Mounting Oscilloscopes in Rack 19 Connecting the Equipment 20 Parts in the N2165A Add One Expansion Kit 20 Connect...

Страница 8: ...es MultiScope Hardware Configuration Guide Infiniium Oscilloscope Software on the Leader Oscilloscope 30 D9010BSEO Infiniium Offline Oscilloscope Analysis Software 30 Go To Using Hosted Infiniium Osci...

Страница 9: ...must be present to ensure that the oscilloscope delivers the best possible measurement accuracy For UXR Series MultiScope systems refer to the Infiniium UXR Series Real Time Oscilloscopes User s Guid...

Страница 10: ...10 Keysight UXR Series and MXR EXR Series MultiScope Hardware Configuration Guide 1 MultiScope System Requirements...

Страница 11: ...t 13 Expansion Equipment Required Table 1 Equipment Required for Two Oscilloscope Rack Mount System Model Description Quantity N2164A UXR Series Multi Frame Base Kit First Two Frames 1 N2156A Rack mou...

Страница 12: ...uctions in the Rack Mount Kit User s Guide mount oscilloscopes in their designated rack locations NOTE Locate oscilloscopes in the rack so that the overall rack center of gravity is about half way up...

Страница 13: ...ultiScope system These parts are used to create a long cable for performing channel deskew Part number Qty Description 54964 61632 5 1 m phase stable cable 54964 60401 1 6 way splitter assembly with r...

Страница 14: ...uts 3 Connect one 54964 61632 cable from the Leader Sample_CLK_Out output to the power divider input 4 Connect two 54964 61632 cables between the power divider assembly outputs and the oscilloscopes S...

Страница 15: ...tiScope Hardware Configuration Guide 15 7 Connect the oscilloscopes to the Leader oscilloscope or external host computer through the desired remote interface connection LAN USB etc 8 If these are the...

Страница 16: ...16 Keysight UXR Series and MXR EXR Series MultiScope Hardware Configuration Guide 2 Two Oscilloscope System UXR Series...

Страница 17: ...UXR Series and MXR EXR Series MultiScope Hardware Configuration Guide 3 Three to Five Oscilloscope Systems UXR Series Expansion Equipment Required 18 Mounting Oscilloscopes in Rack 19 Connecting the E...

Страница 18: ...on Kit Add One Frame of scopes 2 N2156A Rack mount kit of scopes Figure 4 Expansion Accessories Required for Three to Five Oscilloscope Rack Mount System UXR Series oscilloscope UXR Series oscilloscop...

Страница 19: ...s Guide mount oscilloscopes in their designated rack locations NOTE Locate oscilloscopes in the rack so that the overall rack center of gravity is about half way up the rack Because of cable lengths u...

Страница 20: ...EXR Series MultiScope Hardware Configuration Guide 3 Three to Five Oscilloscope Systems UXR Series Connecting the Equipment Parts in the N2165A Add One Expansion Kit Part number Qty Description 54964...

Страница 21: ...ider Place 1250 3745 terminator on all unused divider outputs Reference CLK In Out Trig Out Aux Trig In Sample CLK In Out 10 MHz Out In Reference CLK In Out Trig Out Aux Trig In Sample CLK In Out 10 M...

Страница 22: ...3745 from the power divider output that will be used for the oscilloscope 2 Connect one 54964 61632 cable between the power divider output and the oscilloscope s Sample_CLK_In input 3 Connect one 549...

Страница 23: ...Guide 4 Two Oscilloscope System MXR EXR Series MXR EXR Series Oscilloscope Requirements 24 Connections 25 Connections for Reference Clock Skew Calibration 26 This chapter describes how to configure t...

Страница 24: ...scilloscope MultiScope systems made up of MXR EXR Series oscilloscopes you can use the N2124A multi frame cable kit Refer to your analysis software documentation for additional Infiniium application s...

Страница 25: ...zation 1 Connect TRIG OUT from the Leader to AUX TRIG IN on the Follower through a BNC cable 2 Connect 10 MHz REF OUT from the Leader to 10 MHz REF IN on the Follower through a BNC cable Figure 6 Conn...

Страница 26: ...for the optional drift correction 1 Connect the Follower s AUX OUT signal to the channel 4 inputs on both oscilloscopes using BNC cables and a passive power splitter or divider From the N2124A multi f...

Страница 27: ...in the previous chapters of this manual In this case you can let the Infiniium oscilloscope software perform calibration without being prompted to change connections Individually Calibrate the Oscill...

Страница 28: ...ope calibration is included in the N2164A UXR Series Multi Frame Base Kit These parts are used to create a long calibration cable The long calibration cable is connected from the Follower 1 oscillosco...

Страница 29: ...061 5311 adapter 3 5 mm female to female 1 85 mm 5061 5311 adapter 3 5 mm female to female 1 0 mm 5067 1393 adapter 1 mm ruggedized female to 2 92 mm female Cal Out Calibration Cable Connections Follo...

Страница 30: ...iniiScan From the Infiniium Offline software you have only edge and glitch trigger modes No additional computer is required to run the Infiniium Offline software No space for an additional computer is...

Страница 31: ...finiium Oscilloscopes in the Online Help For instructions on Identifying oscilloscopes in the MultiScope system making software connections Time correlating oscilloscopes calibration Using the MultiSc...

Страница 32: ...32 Keysight UXR Series and MXR EXR Series MultiScope Hardware Configuration Guide 5 Next Steps...

Страница 33: ...ck mount 13 expansion accessories 3 F final steps 27 follower oscilloscope 3 5 H host computer 4 5 host computer requirements 30 I in the box MultiScope control software 30 IO Libraries Suite 30 M Mul...

Страница 34: ...34 Keysight UXR Series and MXR EXR Series MultiScope Hardware Configuration Guide Index...

Отзывы: