background image

2

Keysight E8740A-060 Start-up Guide

Notices

Copyright Notice

© Keysight Technologies 2017
No part of this manual may be repro-

duced in any form or by any means 

(including electronic storage and 

retrieval or translation into a foreign 

language) without prior agreement and 

written consent from Keysight Technol-

ogies as governed by United States and 

international copyright laws.

Manual Part Number

E8749A-90600

Edition

Edition 1, November 1, 2017

Printed in:

Printed in Malaysia

Published by:

Keysight Technologies

 

Bayan Lepas Free Industrial Zone,

 

11900 Penang, Malaysia

Technology Licenses 

The hardware and/or software 

described in this document are fur-

nished under a license and may be 

used or copied only in accordance with 

the terms of such license.

Declaration of Conformity

Declarations of Conformity for this 

product and for other Keysight prod-

ucts may be downloaded from the 

Web. Go to 

http://www.keysight.com/

go/conformity

. You can then search by 

product number to find the latest Dec-

laration of Conformity.

U.S. Government Rights

The Software is “commercial computer 

software,” as defined by Federal Acqui-

sition Regulation (“FAR”) 2.101. Pursu-

ant to FAR 12.212 and 27.405-3 and 

Department of Defense FAR Supple-

ment (“DFARS”) 227.7202, the U.S. 

government acquires commercial com-

puter software under the same terms 

by which the software is customarily 

provided to the public. Accordingly, 

Keysight provides the Software to U.S. 

government customers under its stan-

dard commercial license, which is 

embodied in its End User License 

Agreement (EULA), a copy of which can 

be found at 

http://www.keysight.com/

find/sweula

. The license set forth in the 

EULA represents the exclusive authority 

by which the U.S. government may use, 

modify, distribute, or disclose the Soft-

ware. The EULA and the license set 

forth therein, does not require or per-

mit, among other things, that Keysight: 

(1) Furnish technical information 

related to commercial computer soft-

ware or commercial computer software 

documentation that is not customarily 

provided to the public; or (2) Relinquish 

to, or otherwise provide, the govern-

ment rights in excess of these rights 

customarily provided to the public to 

use, modify, reproduce, release, per-

form, display, or disclose commercial 

computer software or commercial com-

puter software documentation. No 

additional government requirements 

beyond those set forth in the EULA 

shall apply, except to the extent that 

those terms, rights, or licenses are 

explicitly required from all providers of 

commercial computer software pursu-

ant to the FAR and the DFARS and are 

set forth specifically in writing else-

where in the EULA. Keysight shall be 

under no obligation to update, revise or 

otherwise modify the Software. With 

respect to any technical data as 

defined by FAR 2.101, pursuant to FAR 

12.211 and 27.404.2 and DFARS 

227.7102, the U.S. government 

acquires no greater than Limited Rights 

as defined in FAR 27.401 or DFAR 

227.7103-5 (c), as applicable in any 

technical data.

Warranty

THE MATERIAL CONTAINED IN THIS 

DOCUMENT IS PROVIDED “AS IS,” 

AND IS SUBJECT TO BEING 

CHANGED, WITHOUT NOTICE, IN 

FUTURE EDITIONS. FURTHER, TO THE 

MAXIMUM EXTENT PERMITTED BY 

APPLICABLE LAW, KEYSIGHT DIS-

CLAIMS ALL WARRANTIES, EITHER 

EXPRESS OR IMPLIED, WITH REGARD 

TO THIS MANUAL AND ANY INFORMA-

TION CONTAINED HEREIN, INCLUD-

ING BUT NOT LIMITED TO THE 

IMPLIED WARRANTIES OF MER-

CHANTABILITY AND FITNESS FOR A 

PARTICULAR PURPOSE. KEYSIGHT 

SHALL NOT BE LIABLE FOR ERRORS 

OR FOR INCIDENTAL OR CONSE-

QUENTIAL DAMAGES IN CONNECTION 

WITH THE FURNISHING, USE, OR 

PERFORMANCE OF THIS DOCUMENT 

OR OF ANY INFORMATION CON-

TAINED HEREIN. SHOULD KEYSIGHT 

AND THE USER HAVE A SEPARATE 

WRITTEN AGREEMENT WITH WAR-

RANTY TERMS COVERING THE MATE-

RIAL IN THIS DOCUMENT THAT 

CONFLICT WITH THESE TERMS, THE 

WARRANTY TERMS IN THE SEPARATE 

AGREEMENT SHALL CONTROL.

Safety Information

CAUTION

A CAUTION notice denotes a hazard. It 

calls attention to an operating proce-

dure, practice, or the like that, if not 

correctly performed or adhered to, 

could result in damage to the product 

or loss of important data. Do not pro-

ceed beyond a CAUTION notice until 

the indicated conditions are fully 

understood and met.

WARNING

A WARNING notice denotes a hazard. It 

calls attention to an operating proce-

dure, practice, or the like that, if not 

correctly performed or adhered to, 

could result in personal injury or death. 

Do not proceed beyond a WARNING 

notice until the indicated conditions are 

fully understood and met.

Содержание E8740A-060

Страница 1: ...Keysight E8740A 060 Performance Radar Signal Analysis Solution Start up Guide Performance Radar Signal Analysis Solution with N9041B DSOS804 and VSA89600 software...

Страница 2: ...customarily provided to the public to use modify reproduce release per form display or disclose commercial computer software or commercial com puter software documentation No additional government re...

Страница 3: ...Control Instrument product The affixed product label is as shown below Do not dispose in domestic household waste To return this unwanted instrument contact your nearest Keysight Service Center or vis...

Страница 4: ...4 Keysight E8740A 060 Start up Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK...

Страница 5: ...kList 8 Requirements 8 Full Span Measurements with the N9041B 9 Viewing the noise floor of the N9041B 9 Effect of software pre selector 12 Power Spectral Density Measurement with N9041B 15 Occupied Ba...

Страница 6: ...6 Keysight E8740A 060 Start up Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK...

Страница 7: ...rger than 1 GHz and which requires time sampled data the down converted signal can be routed to the rear wideband IF connector The IF signal can then be analyzed with a DSO804A oscilloscope and VSA896...

Страница 8: ...his guide a test radar signal was generated The modulation used was FMCW Frequency Modulated Continuous Wave with pulse period of 1 to 2 ms Both up and symmetrical FMCW was used A Keysight M8195A 65GS...

Страница 9: ...t the full range input attenuation to zero a Select the Amplitude panel or press the AMPTD key b Select Attenuation tab and tap the Full Range Atten control Enter 0 dB using the soft numeric keypad c...

Страница 10: ...e level from 74 to 84 GHz a Select the Marker panel or press the Marker key b Select the Settings tab and in the Marker Frequency control enter 79 0 GHz c Select Marker Function tab and then the Band...

Страница 11: ...Keysight E8740A 060 Start up Guide 11 Figure 1 Average noise density marker noise at 79 GHz Step Action Notes...

Страница 12: ...which avoids adding additional noise unlike a physical pre selector Step Action Notes 1 Turn on radar source a Connect the radar source to the RF2 port as shown in Figure Observe the spectrum as in F...

Страница 13: ...on process This includes the low side image frequencies which was not completely filtered by the output image filter in the signal generation set up as described in the section Equipment and Software...

Страница 14: ...ide Figure 4 FMCW spectrum without software pre selector 3 Reactivate the software pre selector after viewing waveform a Follow the sequence of the previous step but this time enable the Software Pres...

Страница 15: ...enter 5 0 GHz Ensure that the detector is already in RMS average mode See step 6 of Viewing the noise floor of the N9041B on page 9 2 Change analyzer resolution bandwidth RBW a Select the BW panel or...

Страница 16: ...16 Keysight E8740A 060 Start up Guide Figure 5 Average power spectral density using marker band power function Step Action Notes...

Страница 17: ...mode which measures the bandwidth containing 99 0 by default of the total transmission power Step Action Notes 1 Change to OBW Mode a Press the MODE MEAS hardkey or tap the Screen tab b For Mode Measu...

Страница 18: ...p on the Res BW and Video BW and enter the required parameters accordingly Figure 7 shows the display Figure 7 Spectrum analyzer in OBW mode 4 The readout shows by default 99 OBW of the total power Th...

Страница 19: ...b For Mode Measurement and View choose Spectrum Analyzer Swept SA and Normal This step is required only if spectrum analyzer was in OBW mode after the previous exercise 2 Set the center frequency and...

Страница 20: ...xt Peak Next Pk Right or Next Pk Left controls Change Peak Threshold level in the Pk Search Config tab to make peak search navigation easier Figure 8 Peak power spectrum For the purpose of this sectio...

Страница 21: ...l toggle the Swept Zero switch to Zero Span d Select the BW panel In the Settings tab change the Res BW and Video BW to 8 0 MHz ETSI EN302264 1 document specifies that radiated peak power should ideal...

Страница 22: ...equency span a Select the Frequency panel or press the FREQ hard key b In the Start Freq control enter 25 0 GHz In the Stop Freq control enter 77 0 GHz The detector should be in peak mode If not see s...

Страница 23: ...Keysight E8740A 060 Start up Guide 23 Figure 10 Out of band spurious sweep Step Action Notes...

Страница 24: ...om the N9041B to the oscilloscope s Ch1 input as shown in Figure 11 below b Connect the 10 MHz OUT port from the N9041B to the 10 MHz Ref In of the DSOS804 Figure 11 Connection diagram between the N90...

Страница 25: ...the Attenuation tab and tap the Full Range Atten control Enter 0 dB using the soft numeric keypad c Tap the Mech Atten control and enter 0 dB with the soft numeric keypad Or set the attenuation level...

Страница 26: ...ware did not start automatically when launched Note that some working knowledge of VSA software is required to use this section of the guide Please refer to VSA89600 help documentation to learn how to...

Страница 27: ...sBW tab set the parameters to as shown below f In Input Analog tab set the appropriate vertical Range manually or use the Auto range to optimize S N Figure 13 shows the resulting waveform with the FMC...

Страница 28: ...28 Keysight E8740A 060 Start up Guide Figure 13 Output from Ext IF out connector Spectrum seen on VSA89600 and oscilloscope Step Action Notes...

Страница 29: ...to 79 GHz as the center frequency a At the Input User Corrections dialog key in the settings as shown below b In the spectrum trace open the Trace XScale Dialog Trace XScale uncheck Full Scale and ent...

Страница 30: ...0 Keysight E8740A 060 Start up Guide Figure 14 The spectrum on VSA89600 after the correction in step 3 The frequency axis now shows the RF frequency and in the correct positive scale Step Action Notes...

Страница 31: ...r to the oscilloscope input a Perform the steps described in Using Wideband IF Output on page 24 up to step 9 2 Change measurement type to FMCW Analysis a Activate the analysis From the MeasSetup menu...

Страница 32: ...to the knowledge that the generated FMCW test has pulse region length of 2 ms b Use other parameters if required to help the software detect and synchronize the FMCW regions 5 Set time parameters for...

Страница 33: ...Keysight E8740A 060 Start up Guide 33 Figure 15 FMCW analysis with the 89601B BN BHP FMCW radar analysis Step Action Notes...

Страница 34: ...34 Keysight E8740A 060 Start up Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK...

Страница 35: ...n is subject to change without notice Always refer to the Keysight website for the latest revision Keysight Technologies 2017 Edition 1 November 1 2017 Printed in Malaysia E8749A 90600 E8749A 90600 ww...

Отзывы: