Keysight Electronic Calibration Modules
RF/Microwave Two Port
Reference Guide
1
General Information
Manual Overview
The purpose of this manual is to help you use your Electronic Calibration (ECal)
module confidently and effectively. ECal is a precision, single-connection
calibration technique which uses fully traceable and verifiable electronic
standards. Each module has unique S-parameter data that is stored in the
module's memory. During calibration, ECal uses this data to calculate the error
terms for your network analyzer.
This manual provides instructions for operating and maintaining your ECal
module. Also included are mechanical specifications and replaceable parts
available for each model.
The 85091/2/3/4/6/8/9D series provide two-port calibration solutions with
operating frequencies starting as low as DC and ending as high as 9 GHz.
The
N4690/1/2/3/4/6D series provide two-port calibration solutions with
operating frequencies starting as low as DC and ending as high as 67 GHz.
and N7550/1/2/3/4/5A series provide two-port calibration solutions with
operating frequencies starting as low as DC and ending as high as 26.5 GHz.
The N4431/2/3D series provide four-port calibration solutions with operating
frequencies starting as low as DC and ending as high as 26.5 GHz.
Prerequisite Knowledge
This manual assumes you are trained in proper connector care. Because an
accurate calibration depends on the integrity and cleanliness of the connector
interface, a damaged connector will invalidate the calibration achieved with
that module. Refer to the
Clarifying the Terminology of a Connector Interface
In this manual, adapters, ECal modules, and gage masters are referred to by
way of their interface connector. For example:
— A female adapter has a female interface.
— A male adapter has a male interface.
A connector gage is referred to by way of the connector it measures. For
example:
— A male connector gage has a female interface so it can measure male
devices.
Содержание 85091D
Страница 4: ...4 ...
Страница 44: ...1 36 Electronic Calibration Modules Reference Guide General Information Safety and Regulatory Information 1 ...
Страница 66: ...2 22 Electronic Calibration Modules Reference Guide Preparing ECal for Use Operating and Safety Precautions 2 ...
Страница 82: ...3 16 Electronic Calibration Modules Reference Guide Operating ECal Module ECal Troubleshooting 3 ...
Страница 170: ...6 14 Electronic Calibration Modules Reference Guide Replaceable Parts Other ECal Accessories 6 ...
Страница 171: ......