Figure 28 – Terminate Input Wiring RTE - PIR & Push Button
Notes
Diagram illustrates CA8500B. Connections
also apply to CA250B & CA4500B.
- CA250B
– up to 2 Request to Exits
- CA450B
– up to 4 Request to Exits
- CA8500B
– up to 8 Request to Exits
Lens
NO
COM
PIR
(Request To Exit)
NO = Normally Open
PIR
Motion Sensor RTE (Request to Exit)
– ½ second
pulse
Determines the amount of time the output relays
will energize when motion is detected.
RTE
Push Button
COM
NO
NO = Normally Open
“Two devices wired in
parallel to each other”
Single end of line supervision
to Request
to Exit
to Common Return
Double end of line supervision
1K
3K
COM
NO
to Request
to Exit
to Common Return
1K
COM
NO
Note
If using supervision, it is only required on the device farthest from the ACU
terminal. Example shows supervision on RTE Push Button.
No supervision
Cut View of CA8500B
Door Inputs - A
RTE Inputs - B
8
7
6
5
4
3
2
1
Common
8
7
6
5
4
3
2
1
AUX Inputs - C
8
7
6
5
4
3
2
1
Common
Common
AUX Inputs - D
16
15
14
13
12
11
10
9
Common
AUX Inputs - E
24
23
22
21
20
19
18
17
KI-00132E-10-13
Supervision level set in Client software:
System VII & Vantage
– Site Unit Setup
Aurora
– Hardware Setup
Supervision level applied to all door inputs, RTE
inputs, and auxiliary inputs.