Figure 66 – HID 5355 Wiring
Notes on HID 5355
The HID 5355 is suitable for indoor and outdoor use. Maximum read range at 12VDC – ProxCard II card is
9" (22 cm) – ISO ProxII card is 8" (20 cm).
Shield not connected.
Isolate with electrical tape.
Shield
ACU Ground
Lug
Red
+
VDC
Black
to separate DC
power
supply
6 conductors shielded 22 AWG
500 ft (152.4 m) maximum
Reader terminal on control board
LED D1
WHT
D0
GRN
PWR
RED
GND
BLK
C1
(BEEP)
L
E
D
D
1
(
W
h
ite
)
D
0
(
G
re
e
n
)
P
W
R
(
R
e
d
)
G
N
D
(
B
la
c
k
)
P
re
-a
le
rt
(Y
e
llo
w
)
D
1
(
W
h
ite
)
D
0
(
G
re
e
n
)
P
W
R
(
R
e
d
)
G
N
D
(
B
la
c
k
)
L
E
D
P
re
-a
le
rt
(Y
e
llo
w
)
Yellow (Beeper) used for pre-alert
otherwise isolate and tape back.
If connecting external sound device,
see Pre-Alert Relay Option or refer to
ACU cut sheet enclosed with panel
for ACU/OCB8 relay assignments.
Note -
If Pre-alert is connected,
the reader cannot read any
HID 125 kHz-compatible card
during the pre-alert beep.