Enable IGMP Snooping. Check “Snooping Enabled” and verify that “Fast Leave” is also enabled. Uncheck
“Unregister IPMCv4 Flooding enabled”
a.
The path is:
Configuration
->
IPMC
->
IGMP
->
Basic Configuration
7.
Create an IGMP VLAN. The ID should be set to 1. Force IGMPV2 compatibility for this VLAN. Ensure the
configuration is as below:
a.
The path is:
Configuration
->
IPMC
->
IGMP
->
VLAN Configuration
8.
Reboot the network switch and verify that the settings are correct. The switch is now ready for the KD-IP922
system.
a.
There is no need to save the running configuration of this network switch. The settings will persist
on system reboot.