25
EN
MOTOR 1 CURRENT (mA)
MOTOR 2 CURRENT (mA)
MOTOR 1 POSITION (%)
MOTOR 2 POSITION (%)
MOTOR 1 SPEED (%)
MOTOR 2 SPEED (%)
TOTAL CYCLES (CYCLES)
CYCLES LEFT BEFORE SERVICE
SOFTWARE VERSION
4.6 - Diagnostic
A number of parameters, including the current absorption or motor speed, can be viewed at any time using this function. Proceed as follows:
4.7 - Customising the system - BASIC SETTINGS
If necessary, users may select the BASIC SETTINGS, which allow
modification of the control unit’s basic parameters.
Proceed as follows:
PARAMETERS
DESCRIPTION
DEFAULT
MIN.
MAX.
UNIT
1
AUTOMATIC
CLOSING TIME
Automatic reclosure time (0 = off)
Seconds of delay before the gate recloses automatically
after opening
0
0
900
s
2
AUTOMATIC
CLOSING AFTER
TRANSIT
Reclosing time after transit (0 = off) Seconds of delay
before the gate recloses automatically after excitation of
photocell 1 during opening or with the gate open.
0
0
30
s
3
SENSITIVITY
Motor sensitivity, sensitivity when detecting an obstacle.
1 = minimum sensitivity, maximum force on obstacle
10 = maximum sensitivity, minimum force on obstacle
3
0
10
4
OPENING
SPEED
Motor speed during opening
1 = minimum
2 = low
3 = medium
4 = high
5 = maximum
4
1
5
5
SLOW DOWN
OPENING SPEED
Motor speed during opening deceleration phase.
1 = minimum
2 = low
3 = medium
4 = high
5 = maximum
1
1
5
6
CLOSING SPEED
Motor speed during closing
1 = minimum
2 = low
3 = medium
4 = high
5 = maximum
4
1
5
14A
14A
BASIC
SETTINGS
DIAGNOSTIC