![Kett LE-330J Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/kett/le-330j/le-330j_operating-manual_1958602035.webp)
35
11. Data output format
(1) Transmission of data
The 330 series may be connected to either an optipnal printer or PC printer to out measurement data or statistical results.
Digits
Output
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
*
A P P L
N O = 1
LF CR
*
L O T
1 0 0
*
D A T E
1 2 : 3 4 : 5 6
*
U . L I M
5 0 . 0
µ
m
*
L . L I M
5 . 0
µ
m
N = 0 0 0 1
2 3 . 4
µ
m
N = 0 0 0 2
6 5 . 2
!
µ
m
N = 0 0 0 3
-
1 . 0
!
µ
m
N = 0 0 0 4
Example: Data Code
$1B $57 $01 $20 $4E $3D $30 $30 $30 $31 $20 $20 $32 $33 $2E $34 $20 $20 $20 $20 $20 $75 $6D $0A $0D
N = 0 0 0 1
2 3 . 4
µ
m
Notes
* A P P L
N O = 1
* L O T
1 0 0
* D A T E
1 2 : 3 4 : 5 6
* U . L I M
5 0 . 0
µ
m
* L . L I M
5 . 0
µ
m
N = 0 0 0 1
2 3 . 4
µ
m
N = 0 0 0 2
6 5 . 2 !
µ
m
N = 0 0 0 3
- 1 . 0 !
µ
m
N = 0 0 0 4
<Data communications>
Standard RS-232C
<Interface Specifications>
Baud rate
: 2400bps
Data bits
: 8 bits
Stop bits
: 1 bit
Parity bits
: None
Sync format
: synchronous
Signal Level
:
±
9V
<Output Contents>
Soft Command
: 3 digits
Data & Comment : 20 digits
LF Code
: 1 digit
CR Code
: 1 digit
Total
: 25 digits
One digit is consisted of two bytes and contents as per ASCII code table.
Содержание LE-330J
Страница 1: ...330J Series CoatingThicknessTesters LE 330J LH 330J LZ 330J Operating Manual...
Страница 38: ...MEMO...
Страница 39: ......
Страница 40: ...0601 TO 0102 200...