39
7.1 Working conditions diode display
The alarm can be acknowledged with the
test key, i.e. the alarm signal is switched
off during the backwater.
In mains operation, this is indicated by the
alarm LED flashing. All the other optical
displays do not change.
In battery operation, the backwater is in-
dicated by the backwater LED flashing
every second, all other optical displays re-
main dark
2 Device function keys
Alarm key
The alarm can be acknowledged by pres-
sing the alarm key. The alarm-LED flashes
and thus indicates to the operator that the
fault is still pending.
Test key (TEST)
The operating valve can be actuated ma-
nually e.g. for maintenance purposes. The
flap is closed by pressing it once.
The flap is opened again if pressed a se-
cond time.
Closing and opening of the flap is indica-
ted by flashing, the closed flap by the flap
LED lighting up. When the flap is closed,
an acoustic signal (alarm) is given.
Caution: flap does not open automati-
cally!
If backwater occurs while the flap is clo-
sing, this is indicated by the backwater
LED flashing as soon as the flap has been
closed completely. In addition, an alarm is
sounded. During backwater the flap can-
not be opened manually.
Caution:
The end of the backwater is indicated by
the backwater LED going out (optical indi-
cation only!).
The alarm tone no longer changes.
The flap can be opened again using the
test key.
The test key cannot be activated in battery
operation in order to go easy on the bat-
teries!
7.3 Putting the unit out of operation
Caution:
After the mains plug has been
disconnected,
the
alarm
key
must be pressed for at least 5 seconds
until the signal is sounded. This is to de-
activate the battery.
7. Operating the Comfort control unit
Alarm-key
Test-key
Readiness for operation
Power
-LED
green
lit
off
Alarm
-LED
red
off
blinks (1 sec. Takt)
Backwater
Flap closes
Power-LED
green
lit
off
Alarm-LED
red
off
off
Backwater-LED orange
blinks
off
FlapLED
orange
blinks
blinks (1 sec. Takt)
Flap is closed
Power-LED
green
lit
off
Alarm-LED
red
off
off
Backwater-LED orange
blinks
blinks
Flap-LED
orange
lit
off
Acoustic Alarm
Acoustic Alarm
Acoustic Alarm
Mains operation
Battery operation
010-845EN_FKA_Schaltgerät_2011_03_010-131 Stand 10-07_AKTUELL2008.qxd 25.10.11 10:32 Seite 11
Содержание Staufix FKA Comfort
Страница 22: ...22 Notizen...
Страница 23: ...23 Notizen...
Страница 25: ......
Страница 27: ......
Страница 50: ...50 Notice 010 845EN_FKA_Schaltger t_2011_03_010 131 Stand 10 07_AKTUELL2008 qxd 25 10 11 10 32 Seite 22...
Страница 51: ...51 Notice 010 845EN_FKA_Schaltger t_2011_03_010 131 Stand 10 07_AKTUELL2008 qxd 25 10 11 10 32 Seite 23...
Страница 53: ...010 845EN_FKA_Schaltger t_2011_03_010 131 Stand 10 07_AKTUELL2008 qxd 25 10 11 10 32 Seite 25...
Страница 55: ...010 845EN_FKA_Schaltger t_2011_03_010 131 Stand 10 07_AKTUELL2008 qxd 25 10 11 10 32 Seite 27...
Страница 78: ...78 Note...
Страница 79: ...Note 79...