34 / 61
Installation
2019/11
010-917_SON_EN
3.4.3 Function check system type E
C D
E
F
• Switch the “Mix & Pump” control unit on.
Make sure that the switchover valve is not in the
“disposal” position, since otherwise the contents of the system tank
would be pumped off.
• Set the switchover valve <26> to the position cleaning and shredding
(handle to the right).
• Press the
Start / Stop
key, the pump(s) start(s) to run.
• Carry out a visual inspection through the viewing glass to ensure that
water is being pumped into the system tank through the pressure
pipe <22>.
• Press the
Start / Stop
key, the pump(s) is/are switched off.
Check the water supply function
• Open the cold water and hot water supplies
1
alternately and make sure that water is running into the system
tank via the refill inlet.
• Carry out initialisation and functional check on the
SonicControl
in accordance with the operating instructions
provided (optional).
System type E is now ready to use.
3.4.4 Function check system type F
C D E
F
Check the function pump(s) / cleaning and shredding
• Switch the “Auto Mix & Pump” control unit on.
• Press the key
Start / Stop
, the menu
Maintenance
appears.
•
Select
automatic operation
and press OK, the menu
Automatic
operation
appears.
• Press OK, automatic operation starts, after the delay has expired
(shown on the display) the pump(s) will start.
• Carry out a visual inspection through the viewing glass to ensure
that water is being pumped into the system tank through the
pressure pipe <22>.
•
Press the ESC key twice and confirm
Cancel emptying?
by pressing
OK, the pump(s) is/are switched off and ready for operation.
1) Hot water is recommended
26
22
Abb. [32]
22
Abb. [33]