28 / 61
Installation
2019/11
010-917_SON_EN
3.3.2.3 Initialising the control unit
The control unit has already been initialised ready for operation. You should still check the presets, however.
Dry running of the pump(s) must be avoided at all costs. Do not press the
Start / Stop
key!
•
Set the nominal size (NS) in accordance with the specification on the type plate, to do this set the DIP switch
(at the top right on the board) as follows:
• Close the housing.
• Tighten the screws <25>.
3.3.3 Control unit for system type F
C D E
F
3.3.3.1 Installing the “Auto Mix & Pump” control unit
The control unit is mounted on the grease separator. To open the control unit proceed as follows:
Caution, risk caused by electric current! The control unit may only be opened when the mains power
supply has been disconnected.
• Move the main switch <23> into the OFF position.
• Undo the screws <25>.
• Open the housing.
1 2
ON
3 4
DIP
1 2
ON
3 4
DIP
1 2
ON
3 4
DIP
1 2
ON
3 4
DIP
NS 2
NS 4
NS 7
N S 1 0
1 2
ON
3 4
DIP
1 2
ON
3 4
DIP
1 2
ON
3 4
DIP
1 2
ON
3 4
DIP
N S 1 5
N S 2 0
N S 2 5
N S 3 0
25
23
Abb. [28]