Installation
33 / 61
2019/11
010-917_SON_EN
3.4.2 Function check system type D
C
D
E F
Check the function of the pump(s)
• Switch the “Auto Mix” control unit on, menu 0, System info, is
displayed.
• Press the OK key, menu
1
appears.
•
Select
Maintenance
=>
Manual operation => Cshredding
the pump(s) is/are switched on.
• Carry out a visual inspection through the viewing glass to ensure
that water is being pumped into the system tank through the
pressure pipe <22>.
•
Press the ESC key, the pump(s) is/are switched off.
Check the function of the solenoid valve for hot water
1
Set in the maintenance menu as follows:
•
Select
Manual operation => Valve part fill
the solenoid valve is actuated. Make sure that the water runs into
the system tank via the refill inlet.
Check the function of the solenoid valve for cold water
Carry out the following settings in the Maintenance menu:
•
Maintenance
=>
Manual operation => Valve fill
the solenoid valve is actuated. Make sure that the water runs
into the system tank via the refill inlet.
Check the function of the remote control (option)
• Carry out initialisation and functional check on the
SonicControl
in accordance with the operating instructions
provided (optional).
System type D is now ready to use.