6. Electrical Connection

Caution!
Connection may only be carried out by a
qualified  electrician.  The  relevant  cur-
rently  valid  directives,  laws  and  stan-
dards  must  be  observed.  Please  heed
the  chapter  “Safety  instructions”  as
well.

In  the  case  of  complete  plants,  the  floating

switch for controlling the feeding unit and the

valve are already connected.

If you are connecting the switch unit yourself,

or the second floating switch is to be used in

addition, please proceed as follows:

Pierce the seals of the cable screw connec-

tions to be used on the switch unit (see Fig. a).

In the case of those screw connections
where  no  cables  are  to  be  routed,  the
seal must not be pierced since they are
required to seal the housing.

Insert the nut and the cage for strain relief

onto the cable (see Fig. b), insert the cable

into the switch unit and connect up accor-

ding to the circuit diagram. A smaller screw-

driver is most suitable for connection, this

should be inserted into the rear chamber of

the connection terminal and pushed down-

wards.  This  opens  the  terminal  and  the

cable can be connected.

Then the nut is tightened by hand (see Fig.

c). Make sure that the cable sheath is ins-

erted right into the housing as otherwise the

seal  and  strain  relief  are  not  guaranteed.

Please note:

When connecting the 2nd floating switch,

remove  the  short-circuit  jumper  between

terminal 3 and 4. For operation without the

2nd floating switch, this short-circuit jumper

has to be closed. Otherwise the system is

not functional.

32

Содержание Aqatronic S 85 025

Страница 1: ...F r Magnet oder 3 Wege Umschalt Ventil Zus tzliche Sicherheitsabschaltung m glich Hohe Betriebssicherheit Bundesweites Servicenetz Art Nr 85 025 Produktvorteile Name Unterschrift Datum Ort Stempel Fac...

Страница 2: ...ull Seite 8 4 3 Anlagenbeschreibung Aqadive Seite 9 5 Montage 5 1 Montage Schaltger t Seite 10 5 2 Montage Schwimmerschalter Seite 11 6 Elektroanschlu Seite 12 7 Bedienung Funktion 7 1 Inbetriebnahme...

Страница 3: ...Repara tur zu beachten sind Vor allen Arbeiten an der Anlage m ssen der Betreiber sowie das zust ndige Fachpersonal diese Anleitung sorgf ltig lesen und befolgen KESSEL AG Einsatzbereich Das Schaltger...

Страница 4: ...iner Ge samtanlage dar Beachten Sie deshalb auch die Bedienungsanleitungen der Gesamtan lage und der einzelnen Komponenten Bei jeder Montage Wartung Inspektion und Re paratur an einer der Komponenten...

Страница 5: ...wimmer Stellung oben Kontakt ge ffnet Schwimmer Stellung unten Kontakt geschlossen Kabelmanteldurchmesser 9 mm Kabelmantelmaterial H07RN F 3G1 VDE Kabell nge 20 m Ver nderungen am Schwimmerschalter Ka...

Страница 6: ...Anschluss Trinkwassernachspeisung Anschluss Schwimmerschalter 1 Anschluss Schwimmerschalter 2 Sicherheitsabschaltung optional Kurzbedienungsanleitung LED gr n Anzeige Betrieb LED orange Anzeige Trinkw...

Страница 7: ...r t das ber bzw Unterschreiten des eingestellten Wasserstands in der Re genwasserzisterne Schwimmerschalter 2 nicht im Lieferumfang enthalten Bei der KESSEL Regenwasserpumpanla ge Aqadive kann optiona...

Страница 8: ...fberuhigung berlaufsiphon schwimmende Entnahme Trinkwassernachspeisebeh lter Schwimmerventil Absperrventil Trinkwassernachspeisung Not berlauf mit Geruchverschlu Pumpe mit Druckschaltautomat 3 Wege Um...

Страница 9: ...lung Zisterne Einlaufberuhigung berlaufsiphon schwimmende Entnahme Pumpe Druckschaltautomat Absperrventil Betriebswassernetz Trinkwassernachspeisung Magnetventil Trinkwassernachspeisung Absperrventil...

Страница 10: ...as Schaltger t an geeigneter Stelle z B in Augenh he an der Wand montiert Sp ter mit max 1 Nm wieder verschrauben selbstschneidende Schrauben Den Schalt kasten wie abgebildet mit den 4 Holzschrau ben...

Страница 11: ...ragen um ein Ansaugen aus der Sedi mentschicht der Zisterne zu verhindern Bei Verwendung eines zweiten muss derAb stand zum unteren Schwimmerschalter so gro gew hlt werden da sich beide nicht ber hren...

Страница 12: ...iese zur Abdichtung des Geh uses dient Die Mutter und den Korb f r die Zugentla stung auf die Leitung aufstecken siehe Abb b die Leitung in das Schaltger t ein f hren und entsprechend Anschlu plan an...

Страница 13: ...13 6 Elektroanschluss Anschluss Magnetventil Anschluss 3 Wege Umschaltventil...

Страница 14: ...Wasserstand liegt ber dem Niveau 1 l uft die Anlage im Regen wasserbetrieb Im Bedarfsfall wird Betriebs wasser aus der Zisterne zum Verbraucher gef rdert Sinkt der Wasserstand unter das Niveau 1 wird...

Страница 15: ...in der Zister ne das Niveau 4 so wird eine evtl bestehen de automatische oder manuelle Trinkwas sernachspeisung abgeschaltet und verriegelt auch manuell nicht einschaltbar Die Trinkwassernachspeisung...

Страница 16: ...den Herstel ler vorgenommen werden Das Schaltger t bedarf keiner Wartung Der Schwimmerschalter ist in regelm igen Abst nden auf Verschmutzung undAusrich tung zu kontrollieren Dabei ist auf eine scho...

Страница 17: ...die Gew hrleistungsfrist neu zu laufen jedoch nur im Umfang der Neu lieferung Es wird nur f r neu hergestellte Sachen eine Gew hrleistung bernommen Die Gew hrleistungsfrist betr gt 24 Monate ab Ausli...

Страница 18: ...inie des Rates zur Angleichung der Rechtsvorschriften der Mitgliedstaaten betreffend elektrische Betriebsmittel zur Verwendung innerhalb bestimmter Spannungsgrenzen 73 23 EWG festgelegt sind Zur Beurt...

Страница 19: ...Telefon Telefax Ausf hrende Elektrofirma Adresse Telefon Telefax Abnahmeberechtigter Adresse Telefon Telefax bergabeperson Sonstige Anmerkungen Die Inbetriebnahme laut EBA und Einweisung wurde im Bei...

Страница 20: ...20 bergabeprotokoll I I I I I I...

Страница 21: ...c or manual drinking water feeding can be selected For solenoid or 3 way switch over valve Additional safety switch off possible High operational security Nationwide service network Art 85 025 Product...

Страница 22: ...System description Aqadive Page 29 5 Installation 5 1 Installation of the switch unit Page 30 5 2 Installation of the floating switches Page 31 6 Electrical Connection Page 32 7 Operation 7 1 Initial...

Страница 23: ...n maintenance and repair Prior to carrying out any work on the plant the operator and the responsible technical per sonnel must carefully read and heed these instructions KESSEL AG Area of application...

Страница 24: ...eeded The system represents one component in a whole plant Please therefore also heed the operating instructions for plant as a whole and the individual components During as sembly maintenance service...

Страница 25: ...k contact Float position top Contact broken Float position bottom Contact made Cable sheath diameter 9 mm Cable sheath material H07RN F 3G1 VDE Cable length 20 m Changes to the floating switch cable o...

Страница 26: ...e 1 m Connection drinking water feeding Connection floating switch 1 Connection floating switch 2 optional safety switch off Brief operating instructions LED green for operation LED orange for drinkin...

Страница 27: ...ter level in the rain water cistern is exceeded or not reached Floating switch 2 not included in the scope of supply In the case of the KESSEL rainwater pum ping system Aqadive a second floating switc...

Страница 28: ...Overflow siphon Floating removal Drinking water feeding tank Floating switch Shut off valve for drinking water feeding Emergency overflow with odour trap Pump with automatic pressure switch 3 way swi...

Страница 29: ...ing Cistern Feed slowdown Overflow siphon Floating removal Pump Automatic pressure switch Shut off valve service water network Drinking water feeding Solenoid drinking water feeding Shut off valve dri...

Страница 30: ...etely installed in the system If used separately the switch unit is installed in a sui table spot e g at eye level on the wall Screw in place self cutting screws later using max 1 Nm Attach the switch...

Страница 31: ...15 20 cm in order to prevent se diment being suctioned in from the bottom of the cistern When a second floating switch is used the di stance to the lower floating switch must be big enough to prevent...

Страница 32: ...al must not be pierced since they are required to seal the housing Insert the nut and the cage for strain relief onto the cable see Fig b insert the cable into the switch unit and connect up accor din...

Страница 33: ...33 6 Electrical Connection Anschluss Magnetventil Anschluss 3 Wege Umschaltventil...

Страница 34: ...nwater cistern is full enough with the water level above level 1 the system runs in rainwater mode When required service water is pumped from the cistern to the consumer If the water level drops to be...

Страница 35: ...r level in the cistern rises above level 4 any automatic or manual drinking water feeding is switched off and locked cannot be swit ched on manually either Drinking water feeding can only be activated...

Страница 36: ...y only be carried out by the manu facturer The switch unit does not require any mainten ance The floating switch must be checked for soiling and alignment at regular intervals It must al ways be handl...

Страница 37: ...ment and not ne cessarily to the entire product or unit KES SEL products are warranted for a period of 24 month This warranty period begins on the day the product is shipped form KES SEL to its custom...

Страница 38: ...EEC Electromagnetism Guidelines 89 336 EEC Low Voltage Guidelines 73 23 EEC Kessel AG D 85101 Lenting we declare that the product Type KESSEL Control unit Aqatronic S is in agreement with EN 55014 EN...

Страница 39: ...e Fax Authorised acceptance representative Address Phone Fax Person handing over Other comments The putting into service according to the EBA and instruction was carried out in the presence of the aut...

Страница 40: ...verschl sse Hebeanlagen Abl ufe Rinnen innerhalb von Geb uden Abl ufe au erhalb von Geb uden Abscheider Fettabscheider l Benzinabscheider St rkeabscheider Sinkstoffabscheider Kleinkl ranlagen Sch chte...

Отзывы: