![Kerbl 345000 Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/kerbl/345000/345000_instructions-for-use-manual_1956663037.webp)
37
OFF
In this mode, the lights are permanently off. The switching times are deactivated. Only select this mode for test purposes,
or if circuits are out of service.
ON
In this mode, the lights are permanently on at full brightness. The switching times are deactivated. Only select this mode
for test purposes.
AUTO
Important: This mode is only available with dimmable circuits 1 and 2
In this mode, you can set the desired brightness in the room. Using the measurement from the sensor, the light control
now attempts to constantly achieve this level of brightness. The lights are therefore dimmed until the sensors feed back
the set brightness value. If the lights are already dimmed to the lowest value, but the sensor still measures a higher
brightness than you wish, the light will be switched off after a delay. If the measured brightness falls below the desired
value by a certain margin, the lights are switched on. The set switching times (see section 9.5) are active. For this mode,
please see section 6 for the correct positioning of the sensor. Please assign the sensor to the light circuit as described
in section 9.3.
DIM
Important: This mode is only available with dimmable circuits 1 and 2.
In this mode, the lights are always dimmed to the set value. The sensor has no influence on the switching and dimming
state of the lights. The brightness of the lights can be influenced using the external buttons, depending on how they are
set (see section 9.6.2). The set switching times (see section 9.5) are active.
MAN
This mode is only available with circuits 3 and 4.
In this mode, the light sensor has no influence on the switching state of the lights. If set accordingly (see section 9.6.2),
the light can be switched on and off via external buttons (100 % / 0 %). The set switching times (see section 9.5) are
active.
TWILI
In this mode, the light is switched on when the twilight sensor feeds back a light value below the threshold value.
The light is switched off when the light value outside exceeds the threshold for a longer period. The set switching times
(see section 9.5) are active. For this mode, please see section 6 for the correct positioning of the sensor. Please assign
the sensor to the light circuit as described in section 9.3.
9.2.2 Setting the control mode
In the main menu you will see the following display:
Navigate to a “C I R C T 1” to “C I R C T 4” display, to
configure the circuit in question. When you press <- to
confirm, you will come to the configuration screen for the
selected circuit:
c
1
2
3
12.15
150
-> C I R C T 1
C I R C T 2
C I R C T 3
C I R C T 4
Settings
Sensor stgs
Содержание 345000
Страница 45: ...45...