36
7. Bringing into operation
CAUTION!
Risk of physical injury and material damage if used incorrectly!
• Only bring the light control into operation once all installation work is complete.
All cables must be insulated. The housing must be closed.
• When brought into operation, it is possible that the light circuits will be switched on immediately
(depending on the sensor reading). Make sure that no danger can result from switched on lights.
a) Switch on the power supply to the light control. Switch on switches S1 and S2.
b) The language selection screen appears on the display. Using the ^ and v keys, move the cursor to your desired
language, and press the <- key to confirm.
c) The following display appears, and a prompt for setting the time.
• The hour value in the time display flashes.
Set the hour to the correct time using the ^ and v keys.
Press <- to confirm.
• The minute value in the time display flashes.
Set the minute to the correct time using the ^ and v keys.
Press <- to confirm.
• If no time entries are made for a longer period,
the light control changes to the main menu.
You can change the time later whenever you wish,
see section 9.7.
8. Emergency switch
If the lighting system has a technical fault, you can at least start up parts of the system
using the four little switches of the light control.
• Use switch 1 (S1) to switch off the control electronics of the light control.
This will help you to perform a restart, for example, or to remain able to act despite
a fault in the electronics.
• Use switch 2 (S2) to isolate the dimming cables from the device. If there is a fault
in the dimming cables, by isolating them you can at least have the remaining system
working at full brightness without a dimming signal.
• Use switches 3 (S3) and 4 (S4) to switch on circuits 1 and 2 continuously and
independently of any sensor or button signals.
9. Settings
9.1 Menu navigation
You can select the next item in the menu using the ^ and v keys. The -> symbol appears on the display. Press <- to
confirm your selection. This takes you to the submenu you have just selected, or you can change the selected value.
If you select a value in the menu and press <-, the -> symbol on the display changes to *. You can now change the
selected value using ^ and v. By pressing and holding these keys, you can change the value quickly. Press <- again
to confirm the changed value. The * symbol changes back to ->.
9.2 Control modes
9.2.1 Possible control modes
The following control modes are available for controlling the light circuits.
c
1
2
3
12.15
150
KERBL
LED Light Control
Hardware vers.:
Software vers.:
Time: 00 : 00
Содержание 345000