When this function is
NOT SELECTED
the internal relay will ONLY be switched
OFF
in response to
HIGH
Temperature or Timer ALARM
and
ON
when Temperature is
LOWER
than
PRESET
for HIGH ALARM even if it is
lower than preset LOW ALARM.
2.
In
Timer/Stopwatch Alarm
mode:
When set, this function enables internal relay to be switched
OFF
when Timer is
NOT Active
or when Timer
ALARM
occurs (count-down finished). Internal relay will be switched
ON
when
count-down
is
pending
.
When this function is
NOT SELECTED
the internal relay will ONLY be switched ON when Timer ALARM occurs
(count-down finished),
NOTE that
Count-Up
Timer/Counter does not control the internal relay.
Fn 19
Temperature display with Decimal Point.
Fn 20
MIN/MAX Temperature Memory display Enable.
Fn 21
BCD Time Code Slave receiver Enable. (compatible with Simplex BCD code for 50Hz and 60Hz line)
Fn 22
POWER LINE FREQUENCY BASED AUTO-CORRECTION Enable.
Fn 23
POWER LINE CARRIER SYNC FUNCTION Enable.
( Also see Fn 11,12,13,14 )
Fn 24
MANUAL BRIGHTNESS CONTROL Enable.
When set, this function allows for manual control of display brightness by activating “SELECT-NXT” key. Once set,
the brightness level will be memorized even if this function is subsequently disabled.
Fn 25
AUTO-DIMMING BRIGHTNESS CONTROL Enable.
Fn 26
INVERTED SECONDS display for 6 digits model.
Fn 27
INTERNAL TEMPERATURE PROBE selection for operation in Thermostat modes and Temperature Min/Max
memory functions. If not enabled, the EXTERNAL sensor is used.
Fn 28
NOT
USED
Fn 29
Hi/Lo Temperature Alarm
Display
Enable.
Fn 30
Hi/Lo Temperature
Control and Alarm Mode
.
Fn 31
EVENT UP/DOWN COUNTER mode selection. (Function
Fn 39
must also be enabled)
When selected, this function enables the Counter of Pulses presented at the COUNTER INPUT terminal if the
External Counter/Timer Inputs are enabled (by
Fn 36
) or “Clocked“ by the remote control UP and DOWN buttons if
the external inputs are not enabled.
Counter Result (count) display is enabled by
Fn 7
.
The Counter operates as UP-COUNTER when the preset count is equal 000000 or as UP and DOWN-COUNTER
when the preset is different than 000000 but will not allow for clocking down from count 000000.
NOTE that in the EVENT COUNTER mode the range is 9999 if 6-digit display format is not selected (see Fn 9 )
.
Fn 32
2-WIRE (RS232/485) MASTER CLOCK Mode for
synchronized system. (also see Fn 46,53,54,55,59 )
When enabled, this mode will cause the clock to function as a
Synchronized System Master Clock
.
See also functions Fn 33 and Fn 34 .
NOTE: This mode may only be used when the External Communication terminals are installed. A 2-conductor
(twisted pair) cable should be connected in a network with a Master Clock present and setup as a transmitter.
Fn 33
2-WIRE (RS232/485) SLAVE clock Mode in
DISPLAY REPEAT
synchronized system.
All display
data will be copied as sent from Active Master clock display in real time. Time data will not be updated in
Slave clock unless Function Fn 34 is also enabled.
Only the clock Preset/Programming mode can override this mode.
NOTE: This mode may only be used when the External Communication terminals are installed. A 2-conductor
(twisted pair) cable should be connected in a network with a Master Clock setup as transmitter using SELENA Time
Sync protocol.
Fn 34
2-WIRE (RS232/485) SLAVE clock Mode in
TIME
synchronized system. (also see Fn 46)
Only time data will be synchronized in this mode. All other local options and modes may be still selected.
NOTE: This mode may only be used when the External Communication terminals are installed. A 2-conductor
(twisted pair) cable should be connected in a network with any type of a PC or a Master Clock present as a
transmitter.
Fn 35
STOPWATCH in 1/100 resolution Mode.