V — PRELIMINARY OPERATIONAL CHECK.
A simple operational check after unpacking and before
equipment installation is advisable to ascertain whether
the power supply has suffered damage resulting from
shipping.
1. With both control and power boost section
POWER switches set to off position, connect the
power supply to source power (see “Input Con-
nections.” on page 5.
2. With no load connected, set both control and
power boost section POWER switches to the ON
position. Each time the unit is turned on an inter-
nal self-test is performed. If all tests pass, the unit
goes into the default mode. If a failure occurs, the
failure is displayed. Figure 5 shows the factory-
configured power on defaults displayed on the
LCD.
3. Connect a digital voltmeter (DVM) (resolution and
accuracy of 0.01% or better) to the OUT S and
COM S terminals at the BOP 2K rear panel termi-
nal block.
4. Use the keypad to enter the rated maximum volt-
age of the power supply (e.g., enter 144 for a
model BOP 144-14MG) and press
ENTER
. If
STANDBY indicator is lit, press
STANDBY
key.
5. Verify DVM voltage reading agrees with pro-
grammed voltage within 0.03% of rated maximum
voltage and agrees with displayed voltage on
LCD within 0.05% of rated maximum voltage.
VI — ACCESSORIES.
See Table 3.
TABLE 3. ACCESSORIES
ITEM
FUNCTION
PART NUMBER
Mating Connector, Trigger
Mates with Trigger port.
142-0527 (Kepco)
SP2501 (CUI Stack)
IEEE 488 Cable, (1 meter long) For MG models only. Connects BOP power supply to GPIB bus.
SNC 488-1
IEEE 488 Cable, (2 meter long) For MG models only. Connects BOP power supply to GPIB bus.
SNC 488-2
IEEE 488 Cable, (4 meter
longs)
For MG models only. Connects BOP power supply to GPIB bus.
SNC 488-4
RS 232 Cable Kit
Contains RJ11 to RJ45 Patch cord, RJ 45 Patch cord, two RS 232 adapters,
one with male pins to connect to DTE equipment and one with female pins to
connect to a PC (personal computer), two RS 232 Loop Back test Connec-
tors (one 6-pin and one 8-pin) to test RS 232 communication and aid in iso-
lating RS 232 communication problems.
KIT 219-0436
RS 232 Adapter (Male pins)
Allows RS 232 port to be connected to DTE equipment. (Supplied in KIT
219-0436.)
142-0487
(L-COM RA098M)
RS 232 Adapter (Female pins)
Allows RS 232 port to be connected to a PC (personal computer). (Supplied
in KIT 219-0436.)
142-0506
(L-COM RA098F)
15-pin DSUB Connector
Mating connector for Analog input connector A2A5J6
Dsub 15 pin hood
Dsub 15 pin male
108-0374
(Tyco-Amp 207470-1)
142-0449
(Amphenol 17S-DA15P)
IDC 6-pin connector
Mating connector for RS-232 PORT, connector A1J5 and PROTECTION
EXT. PORT, connector A2A5J7
142-0536
(Amphenol 5-555176-3)
Heat Sink
Provides adequate cooling for calibration sense resistors.
136-0451