HOW TO MODIFY A PARAMETER. 

First access the parameter by accessing the proper
menu as described above. To modify a parameter
listed in a menu or submenu, proceed as follows:

1. Highlight the parameter using the 

Y

 and 

U

 

keys.

2. When the desired choice is highlighted, press 

!

to modify the active setting. The choices are dis-
played with the active setting highlighted. In the
case of numerals, the units digit is highlighted. 

To change a numeric setting, press the num-
ber keys, then press 

ENTER

 to program the

numbers entered. Use the 

CLEAR key

 to

clear numbers entered and start over. The

ADJUST 

control can also be used to incre-

ment or decrement the highlighted digit.
Pressing 

ADJUST

 while rotating adjusts the

least significant digit. If the output is on (unit
not in Standby) changes made using the

ADJUST 

control are immediately applied to

the output.

For alphanumeric characters use multiple
presses of the number keys for letters or sym-
bols: 

0

 (space), 

1

 (+, –, /), 

2

 (ABC), 

3

(DEF), 

4

 (GHI), 

5

 (JKL), 

6

 (MNO). 

7

(PQRS), 

8

 (TUV), 

9

 (WXYZ). Use the 

T

key to highlight the next character. As an alter-
native, the 

U

 or 

Y

 keys or 

ADJUST

 control

will scroll through numbers, and letters and
symbols. Use the 

CLEAR

 key to clear the

entire alphanumeric field and start over

3. Press 

$

 to apply the change and return to the

menu (to change another parameter, repeat steps
1 and 2). To abort (return to the menu without
applying the change), press 

%

 NOTE:Press 

HELP 

key for more information,

press 

HELP

 again to see multiple

screens; press 

CLEAR 

key to exit the

help screen.

FIGURE 6.  BOP 2KW SERIES, REAR PANEL VIEW, LINKS INSTALLED FOR LOCAL SENSING

Содержание BOP 10-200ME

Страница 1: ...ing instructions including an Installation Operation Summary which includes hyperlinked references to detailed procedures but which can be printed as a handy reference The BOP 2KW MG ME Operator s Man...

Страница 2: ...ering many electrochemical reactions Models with L suffix have been optimized for exceptionally low current ripple and noise and improved stability drift and temperature making them ideal for driving...

Страница 3: ...th displayed voltage on LCD within 0 05 of rated maximum voltage VI ACCESSORIES See Table 3 TABLE 3 ACCESSORIES ITEM FUNCTION PART NUMBER Mating Connector Trigger Mates with Trigger port 142 0527 Kepc...

Страница 4: ...4 228 1915 053119 KEPCO INC 131 38 SANFORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 1 BOP OUTPUT CHARACTERISTICS...

Страница 5: ...Terminal Block Then connect OUT S and COM S lines from the BOP 2KW Sense Monitor Terminal Block to the load see Figure 7B using 22 AWG wire twisted pair ANALOG I O CONNECTIONS The Analog I O Port conn...

Страница 6: ...load exists contacts cannot be held closed by actuator When the power supply is turned on it per forms a brief self test that includes testing the three processors analog interface and dis play and an...

Страница 7: ...con figuration shown as a power up setting so the changes will not be lost when the unit is turned off APPLY EXIT applies the current changed setting without saving for power up and exits to the previ...

Страница 8: ...AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 4 BOP 2KW SERIES POWER BOOST SECTION FRONT PANEL CONTROLS AND INDICATORS FIGURE...

Страница 9: ...o incre ment or decrement the highlighted digit Pressing ADJUST while rotating adjusts the least significant digit If the output is on unit not in Standby changes made using the ADJUST control are imm...

Страница 10: ...channel is determined by the MODE key in local mode which alternately selects either Voltage mode or Current mode or by SCPI com mand in digital remote mode The protection channel is determined automa...

Страница 11: ...l are possible Otherwise the value entered is applied to both positive and negative protect channels NOTE The BOP can be configured to show the protection limits as either a single value that applies...

Страница 12: ...loads Table 4 indicates how the power supply responds to a command to go from Output ON to OFF When the output is disabled the unit is set to voltage mode voltage is set to zero and both current prot...

Страница 13: ...opened after the connections are complete and then the switch in series with the battery should be closed If the constant voltage type active electronic load is adjusted to zero before handling the p...

Страница 14: ...com mands via RS 232 GPIB or LAN ports opera tion via web pages Analog Remote Operation via Analog I O port Details about Protect Limits and Software controlled limits Storing Recalling Power Supply...

Страница 15: ...15 15 KEPCO INC 131 38 SANFORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 9 BOP 2KW OUTLINE DIMENSIONS Sheet 1 of 2 REAR VI...

Страница 16: ...NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 10 BOP 2KW WIRING DIAGRAM DETAIL A S MON OUT OUT MON COM GND GND NET OUT MON N C OUT S COM S CO...

Отзывы: