WARNING

For both inductive loads and con-
stant-current-type active electronic
loads when the BOP output is set
to OFF, a path is provided for
absorbing either the energy accu-
mulated in the reactance of the load
during the ON state, or energy
delivered by an electronic load.
This prevents damage to the load
and power supply as well as pro-
viding safety for the user. However,
In addition to the built-in safety fea-
tures, constant-current-type active
electronic loads must be adjusted
to zero and the BOP front panel
LCD must read 0V, minimum cur-
rent, before handling the power
supply-to-load connections. 

Resistive. 

This mode, as the name suggests, is useful

for resistive loads. Table 4 indicates how the power
supply responds to a command to go from Output ON
to OFF.

WARNING

Accessing the BOP after the output
is disabled in BATTERY mode is
hazardous because (1) high current
arcing is possible and (2) either the
external battery voltage, or the volt-
age (±Voltage Protection max) on
the BOP output terminals may be
dangerous. Therefore, for battery
and constant-voltage-type active
electronic loads it is recommended
that two properly rated external
switches be installed for safety:
one in series with the battery, and
one across the BOP output. After
the unit is set to OFF, first open the
switch in series with the battery,
then close the switch across the
BOP output to ensure safety before
handling BOP connections. When

connecting the battery, the switch
across the output should be
opened after the connections are
complete and then the switch in
series with the battery should be
closed. If the constant-voltage-type
active electronic load is adjusted to
zero before handling the power
supply-to-load connections, only
the switch across the BOP output
is required.

Battery

. This mode is necessary for the power supply

to function properly and safely with either battery or
constant-voltage-type active electronic loads. This
mode prevents the battery from discharging during the
OFF state. When the output is disabled (set to OFF),
the BOP will go to current mode, current will be set to
zero, with voltage protect and current limit set to maxi-
mum. In this way the battery will not be discharged
while the output is OFF. For constant-voltage-type
active electronic loads this mode stops energy flow
during the OFF state. Table 4 indicates how the power
supply responds to a command to go from Output ON
to OFF. 

CONFIGURE LOAD TYPE. 

To configure, press

%

 from the power-up screen, then highlight Load

Type and press 

!

 to modify. (If a Password is

required, see Operator’s Manual for instructions.) High-
light Active, Resistive or Battery (see explanations and
associated WARNINGS above) and press 

$

 to save.

Then press 

$

 to save for power-up, 

#

 to abort, or

%

 to apply the changes (without saving for power-up)

and exit. After configuring, the new setting will be effec-
tive when the power supply goes from output on to out-
put off.

To restore factory default (Active), press 

%

 from the

power-up screen, highlight Load Type, press 

!

, then

press 

@

 to restore default. Press 

$

 to save for

power-up or 

%

 to exit

ENABLING/DISABLING OUTPUT POWER. 

The BOP output can be disabled (OFF) or enabled
(ON) by toggling the 

STANDBY

 key in local mode. The

behavior of the unit when disabled depends on the
Load Type setting (See “Max/Min Setting Menu” on
page 12. 8 an
d Table 4 for details). 

Содержание BOP 10-200ME

Страница 1: ...ing instructions including an Installation Operation Summary which includes hyperlinked references to detailed procedures but which can be printed as a handy reference The BOP 2KW MG ME Operator s Man...

Страница 2: ...ering many electrochemical reactions Models with L suffix have been optimized for exceptionally low current ripple and noise and improved stability drift and temperature making them ideal for driving...

Страница 3: ...th displayed voltage on LCD within 0 05 of rated maximum voltage VI ACCESSORIES See Table 3 TABLE 3 ACCESSORIES ITEM FUNCTION PART NUMBER Mating Connector Trigger Mates with Trigger port 142 0527 Kepc...

Страница 4: ...4 228 1915 053119 KEPCO INC 131 38 SANFORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 1 BOP OUTPUT CHARACTERISTICS...

Страница 5: ...Terminal Block Then connect OUT S and COM S lines from the BOP 2KW Sense Monitor Terminal Block to the load see Figure 7B using 22 AWG wire twisted pair ANALOG I O CONNECTIONS The Analog I O Port conn...

Страница 6: ...load exists contacts cannot be held closed by actuator When the power supply is turned on it per forms a brief self test that includes testing the three processors analog interface and dis play and an...

Страница 7: ...con figuration shown as a power up setting so the changes will not be lost when the unit is turned off APPLY EXIT applies the current changed setting without saving for power up and exits to the previ...

Страница 8: ...AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 4 BOP 2KW SERIES POWER BOOST SECTION FRONT PANEL CONTROLS AND INDICATORS FIGURE...

Страница 9: ...o incre ment or decrement the highlighted digit Pressing ADJUST while rotating adjusts the least significant digit If the output is on unit not in Standby changes made using the ADJUST control are imm...

Страница 10: ...channel is determined by the MODE key in local mode which alternately selects either Voltage mode or Current mode or by SCPI com mand in digital remote mode The protection channel is determined automa...

Страница 11: ...l are possible Otherwise the value entered is applied to both positive and negative protect channels NOTE The BOP can be configured to show the protection limits as either a single value that applies...

Страница 12: ...loads Table 4 indicates how the power supply responds to a command to go from Output ON to OFF When the output is disabled the unit is set to voltage mode voltage is set to zero and both current prot...

Страница 13: ...opened after the connections are complete and then the switch in series with the battery should be closed If the constant voltage type active electronic load is adjusted to zero before handling the p...

Страница 14: ...com mands via RS 232 GPIB or LAN ports opera tion via web pages Analog Remote Operation via Analog I O port Details about Protect Limits and Software controlled limits Storing Recalling Power Supply...

Страница 15: ...15 15 KEPCO INC 131 38 SANFORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 9 BOP 2KW OUTLINE DIMENSIONS Sheet 1 of 2 REAR VI...

Страница 16: ...NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 10 BOP 2KW WIRING DIAGRAM DETAIL A S MON OUT OUT MON COM GND GND NET OUT MON N C OUT S COM S CO...

Отзывы: