background image

16

228-1692 REV 3

 112113

KEPCO, INC. 

 " 

 131-38 SANFORD AVENUE 

 "

  FLUSHING, NY. 11355 U.S.A.

  "

  TEL (718) 461-7000

  " 

 FAX (718) 767-1102

 

http://www.kepcopower.com   

 email: [email protected]

Содержание BOP 10-100MG

Страница 1: ...inted as a handy reference The BOP 1KW MG Operator s Manual also includes a full description of the digital interfaces and the SCPI command language FIRMWARE VERSION Refer to www kepcopower com suppor...

Страница 2: ...cell arrays and powering many electrochemi cal reactions II UNPACKING This instrument has been thoroughly inspected and tested prior to packing and is ready for operation After careful unpacking insp...

Страница 3: ...112113 228 1692 REV 3 3 KEPCO INC 131 38 SANFORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 1 BOP OUTPUT CHARACTERISTICS...

Страница 4: ...to DTE equipment and one with female pins to connect to a PC personal com puter two RS 232 Loop Back test Connectors one 6 pin and one 8 pin to test RS 232 communication and aid in isolating RS 232 co...

Страница 5: ...with a current rating compatible with the anticipated input current Line cords available as accessories are listed in Table 3 Plug the source power connector into the source power inlet connec tor at...

Страница 6: ...put for use with SCPI TRG and TRIG commands Refer to Operator s manual for details GPIB CONNECTIONS Your computer must have a GPIB interface card installed Connect the power supply to the computer s G...

Страница 7: ...port located on the rear panel See Fig ure 3 A Null Modem cable is not required for older MAC computers with D sub serial port in which the RXD and TXD line transposition is accomplished via external...

Страница 8: ...tem on the list and pressing the View Modify function key Menus and submenus will display a list of parameters with the top one high lighted The function key assignments can vary but generally offer t...

Страница 9: ...n1 Admin2 or Unprotected Series Parallel Configuration Standalone Parallel Series Master 2X2 Master 3X2 for parallel or series Unit Type Stand alone Master 1 to 4 Slave 1 to 5 and Connection Type show...

Страница 10: ...R CURRENT AND ASSOCIATED PROTECT LIMITS From the power up screen the settable voltage current parameters are displayed at the bottom of the LCD above the HELP message Use Y or U to highlight the main...

Страница 11: ...rmine the maximum value of voltage or current that can be programmed 1 Press from the power up screen to enter the General Setup menu then highlight Max Min Set tings 2 Press to enter the Max Min Sett...

Страница 12: ...nabled the pre existing settings for volt age current protect and voltage limit are restored WARNING For both inductive loads and con stant current type active electronic loads when the BOP output is...

Страница 13: ...F For con stant voltage type active electronic loads this mode stops energy flow during the OFF state Table 5 indi cates how the power supply responds to a command to go from Output ON to OFF CONFIGUR...

Страница 14: ...copower com email hq kepcopower com FIGURE 1 BOP 1KW OUTLINE DIMENSIONS SHEET 1 OF 2 20 000 508 00 21 439 544 54 22 800 579 11 21 564 547 73 22 000 558 79 23 863 606 12 18 235 463 16 18 985 482 21 1 4...

Страница 15: ...FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 1 BOP 1KW OUTLINE DIMENSIONS SHEET 2 OF 2 SLIDES TRAVEL DISTANCE 23 000 584 2 22 000 5...

Страница 16: ...16 228 1692 REV 3 112113 KEPCO INC 131 38 SANFORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com...

Отзывы: