VIII — OPERATION.

Additional features covered in the Operator Manual
are: Quick Boot (eliminating the power- up displays),
use of the internal relay, operation via the LAN inter-
face or analog signals and setting coarse/fine
adjustment preference of the VOLTAGE and CUR-
RENT controls. An Installation/Operation Summary
is also included in the Operator Manual. The Opera-
tor Manual also covers the GPIB and RS
232interfaces, including the use of the drivers down-
loadable from: 
www.kepcopower.com/drivers/drivers-dl3.htm
#bop1k.

TURNING THE POWER SUPPLY ON. 

CAUTION: 

DO NOT repeatedly toggle the cir-
cuit breaker/switch as this may
damage the unit. 

Set POWER ON/OFF circuit breaker/switch on front
panel to ON. If actuator does not lock when
released, wait a few seconds before trying again.
The circuit breaker is “trip-free” design; if overload
exists, contacts cannot be held closed by actuator.

• When the power supply is turned on, it per-

forms a brief self-test that includes testing the
three processors (analog, interface and dis-
play), then displays the power-up screen (see
Figure 5). If an error is detected, the FAULT
indicator will light, information about the error
will be briefly displayed on the LCD.

• If the unit powers up in REMOTE mode, press

!

 to set the unit to LOCAL mode.

• If the display is not viewable, press 

#

 twice.

The display will cycle through the range of
contrast settings. Press 

#

 again to lock in

the preferred contrast. 

ACCESSING THE MENUS. 

From the power-up

screen, pressing the Function keys indicated on the
LCD opens the associated menu. The menu opened
may list submenus that may be opened either
directly by pressing the associated Function keys, or
by highlighting an item on the list and pressing the
View/Modify function key. Menus and submenus will
display a list of parameters, with the top one high-
lighted. The function key assignments can vary, but
generally offer the following choices:

!

 allows the highlighted parameter to be

viewed or modified. After changing the param-

eter, the following choices are available: 

$

 -

SAVE or 

ENTER

 to save the change, 

%

  -

EXIT to abort the change and exit to the previ-
ous menu.

@

 - RESTORE DEFAULT restores factory

defaults for the parameters displayed (except
for GPIB address). The factory defaults may
be saved as power-up defaults by pressing

$

.

#

 - The function varies, depending on the

menu. In most cases 

#

 is used to abort a

change without applying the modified setting.
From the power-up screen 

#

 is used to

adjust contrast. In the Revisions/TEST sub-
menu of the General Setup Menu, 

#

 is used

to execute a test. 

$

 - SAVE FOR POWER-UP Saves the con-

figuration shown as a power-up setting so the
changes will not be lost when the unit is
turned off.

%

 - APPLY EXIT applies the current

(changed) setting without saving for power-up
and exits to the previous menu or to the
power-up screen, EXIT leaves the current
menu without saving or applying changes.

The menu structure is as follows (NOTE: 

BOLD

  =

Factory Default):

Power-up Screen (Power up menu)

!

 - Save/Recall

Saved Setups: Recall one of 99 saved set-
ups.

Saved Setup Details: Mode (voltage/
current), main channel reference (inter-
nal/external/external reference level)
and setting, protection limit (internal/
external/lesser limit) and setting(s), out-
put status (on/off)

@

 - Waveform 

Saved Waveforms: Choose one of 16
saved waveforms.

New Waveform Settings: Name (max.
10 characters), protection settings,
count, mode (voltage/current)

Waveform Settings: Name, protection
settings, count, segment list, mode

Segment Details: Type (square/
±ramp/triangle/sine/level),
frequency or period, p-p amplitude,
offset, start/stop angle for sine and
triangle, initial/repeat

#

 - Display

Display and Beep Settings: Display
(meters/graphics (12 choices)), back-
ground (white/black), contrast, beep (On/
Off/Error only)

!

Содержание BOP 10-100MG

Страница 1: ...inted as a handy reference The BOP 1KW MG Operator s Manual also includes a full description of the digital interfaces and the SCPI command language FIRMWARE VERSION Refer to www kepcopower com suppor...

Страница 2: ...cell arrays and powering many electrochemi cal reactions II UNPACKING This instrument has been thoroughly inspected and tested prior to packing and is ready for operation After careful unpacking insp...

Страница 3: ...112113 228 1692 REV 3 3 KEPCO INC 131 38 SANFORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 1 BOP OUTPUT CHARACTERISTICS...

Страница 4: ...to DTE equipment and one with female pins to connect to a PC personal com puter two RS 232 Loop Back test Connectors one 6 pin and one 8 pin to test RS 232 communication and aid in isolating RS 232 co...

Страница 5: ...with a current rating compatible with the anticipated input current Line cords available as accessories are listed in Table 3 Plug the source power connector into the source power inlet connec tor at...

Страница 6: ...put for use with SCPI TRG and TRIG commands Refer to Operator s manual for details GPIB CONNECTIONS Your computer must have a GPIB interface card installed Connect the power supply to the computer s G...

Страница 7: ...port located on the rear panel See Fig ure 3 A Null Modem cable is not required for older MAC computers with D sub serial port in which the RXD and TXD line transposition is accomplished via external...

Страница 8: ...tem on the list and pressing the View Modify function key Menus and submenus will display a list of parameters with the top one high lighted The function key assignments can vary but generally offer t...

Страница 9: ...n1 Admin2 or Unprotected Series Parallel Configuration Standalone Parallel Series Master 2X2 Master 3X2 for parallel or series Unit Type Stand alone Master 1 to 4 Slave 1 to 5 and Connection Type show...

Страница 10: ...R CURRENT AND ASSOCIATED PROTECT LIMITS From the power up screen the settable voltage current parameters are displayed at the bottom of the LCD above the HELP message Use Y or U to highlight the main...

Страница 11: ...rmine the maximum value of voltage or current that can be programmed 1 Press from the power up screen to enter the General Setup menu then highlight Max Min Set tings 2 Press to enter the Max Min Sett...

Страница 12: ...nabled the pre existing settings for volt age current protect and voltage limit are restored WARNING For both inductive loads and con stant current type active electronic loads when the BOP output is...

Страница 13: ...F For con stant voltage type active electronic loads this mode stops energy flow during the OFF state Table 5 indi cates how the power supply responds to a command to go from Output ON to OFF CONFIGUR...

Страница 14: ...copower com email hq kepcopower com FIGURE 1 BOP 1KW OUTLINE DIMENSIONS SHEET 1 OF 2 20 000 508 00 21 439 544 54 22 800 579 11 21 564 547 73 22 000 558 79 23 863 606 12 18 235 463 16 18 985 482 21 1 4...

Страница 15: ...FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 1 BOP 1KW OUTLINE DIMENSIONS SHEET 2 OF 2 SLIDES TRAVEL DISTANCE 23 000 584 2 22 000 5...

Страница 16: ...16 228 1692 REV 3 112113 KEPCO INC 131 38 SANFORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com...

Отзывы: