13
REMARKS
DISPLAY
PRESS
LO CUT= Low cut-off; Lowest rate
value to be recognized. All rate read-
ings be low the "cutoff" will assume
the "set lo" value. Key in the de sired
value and press RST/ENTER to enter
dis played value.
NOR= Normalizing (averaging) fac-
tor (00.0 to 99.9); Key in the desired
value and press RST/ENTER to enter
dis played value. Higher settings pro-
vide more nor mal iz ing (averaging) for
a more stable display.
This section tells the unit that the high
setting is entered in units per Sec-
ond, Minute, Hour or Day. Press the
PRGM key to step through choices.
Press RST/ENTER to enter displayed
choice.
TDEC= Totalizer Decimal; Press the
arrow keys to enter in the de sired
to tal iz er decimal. Press RST/ENTER
to enter displayed choice. Entering
a decimal will add resolution to the
total. (i.e. tdec=#####.#; 100 will be
dis played as 100.0)
CFDEC= Conversion Factor Decimal;
Press the ar row keys to enter in the
de sired conversion factor decimal.
Press RST/EN TER to enter displayed
choice.
CFAC= Conversion Factor; The con-
ver sion factor allows you to convert
rate to total volume units.
TMUL= Totalizer Multiplier; This fac tor
al lows you to divide the totalizer by 1,
10, 100, 1000
Press the PRGM key to step to the
desired factor. Press RST/ENTER to
enter displayed choice.
Lo CuT
Press any key to view
or change existing
value
NoR
Press any key to view
or change existing
value
sec, NNiNS, HouRS
or
days
or
or
tdec
CFdec
CFac
tmul
Press any key to view
or change existing
value
1
,
10
,
100
or
1000
STEP
4
CONT...
SET TING
SETUP
ENTER
ENTER
PRGM
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
PRGM
NOTE:
See Appendix i
(PG17) for a chart
containing com-
mon conversion
factors