11

PRESS

DISPLAY

REMARKS

input

RELAYS

A RATE, A ToT 

or 

 A PUL

(IF TOT or PUL 

SE LECTED)

DuR A

(hit any key to view  or 

change ex ist ing dur A 

value XX.X)

(IF RATE SELECTED)

HYS A

(hit any key to view  or 
change ex ist ing HyS A 

value XXXXX)

B RATE

B ToT 

or 

b PUL

(IF TOT or PUL

SE LECTED)

DuR B

(IF RATE SELECTED)

HYS B

STEP

2

SET TING

RELAYS

NOTE: 

If  out puts  are 
not  used,    set  

dur  A

  & 

dur 

B

  at  "0.00"  to 

pre vent  the 
counters  from 
re set ting  at 
the presets.

This section of the menu sets up the 
open collector outputs.

Output A assigned to the rate,total or 
pulse  output.    Press  the  PRGM  key 
to toggle be tween choices, press the 
RST/ENTER key to enter the displayed 
choice.

dur A = the duration of time (0.01 to 
599.99 sec) that output A will remain on 
or energized.  When dur A is dis played, 
hit any key to view or change dur A.  
Press  the  RST/ENTER  key  to  enter 
dis played value.  When dur A is set at 
0.00,output A will latch until re set; when 
dur A is set other than 0.00 the counter 
will au tore cycle at Preset A.

Hys (hysteresis)= The number of units 
below  the  preset  that  the  output  will 
remain "ON".  EXAMPLE: Preset set 
@  100;  HyS  set  @  10.    Output  will 
activate (turn on) when rate = 100 and 
turn off when rate falls below 90 (10 
below preset).

Follow instructions for A RATE, A TOT 
& A PUL

Follow instructions for dur A

Follow instructions for hys A 

PRGM

PRGM

ENTER

ENTER

ENTER

ENTER

ENTER

PRGM

ENTER

PRGM

Содержание ES-756

Страница 1: ...756 INSTALLATION OPERATING INSTRUCTIONS MODELS ES756 INT 69RT 99914 01 03 06 KESSLER ELLIS PRODUCTS 10 Industrial Way East Eatontown NJ 07724 800 631 2165 732 649 7100 Fax 732 649 7099 http www kep c...

Страница 2: ...internal circuit boards or devices Handling Procedure 1 Power to unit must be removed 2 Personnel must be grounded via wrist strap or other safe suitable means before any printed circuit board or othe...

Страница 3: ...TYPICAL WIRING HOOKUPS 4 OPEN COLLECTOR 5 PROGRAMMING FLOWCHART 6 DEFINITIONS 7 FRONT PANEL OPERATIONS 10 PROGRAMMING 10 SETTING PRESETS PANEL LOCK 15 TROUBLESHOOTING GUIDE 16 WARRANTY WARRANTY WARRAN...

Страница 4: ...THIS PAGE IS BLANK...

Страница 5: ...tive The unit can provide the DC source as long as the drop across the devices being driven does not exceed 21V Input Type Linear 0 20mA 4 20mA 0 5V 0 10V or 1 5V selectable from the front panel Input...

Страница 6: ...e screws into the rear of the brackets Tighten the screws evenly and alternately A panel less than 0 1 may distort if the clamps are screwed too tightly Do not over tighten Anormal level of torque is...

Страница 7: ...ied on the input and DC ground lines Make sure the input wires are not run into the unit in a bundlewithpowerinputlines Werecommend using shielded cable Connect the shield to DC signal ground of the u...

Страница 8: ...urrent I in 5 Voltage V in 6 Not Used 7 24V Out 8 Preset B Collector 9 Preset A Collector 10 DC In 11 AC Neutral 12 AC Line 1 Reset In 2 Analog Out Sink 3 Signal GRD DC 4 Current I in 5 Voltage V in 6...

Страница 9: ...90 10 below Preset Select PuL pulse output to use the output for remote totalizers When set to PuL a minimum duration in seconds 0 00 to 599 99 can be assigned to the time the output will remain energ...

Страница 10: ...ter displayed value NOTE SEVERAL PROGRAMMING SELECTIONS WILL NOT APPEAR WITH RATE ONLY TOTAL ONLY UNITS OPTIONS NOT ORDERED WILL NOT APPEAR IN PROGRAM SELECTIONS For best results choose the highest re...

Страница 11: ...ERESIS FOR OUTPUT A This value is the number of units below Preset A that the output will remain ON EXAMPLE Preset A set at 100 Hys set at 10 Output A will activate turn on when the rate equals 100 Ou...

Страница 12: ...raging factor 00 0 to 99 9 Higher settings provide more nor malizing averaging for a more stable display Derived from the equation OLD DATA x NOR NEW DATA OLD DATA x NOR NEW DATA NOR 1 Sec SECONDS Thi...

Страница 13: ...the left digit when viewing the Peak The peak value is the highest rate reading that the unit had displayed since the peak had been reset The peak is not retained in memory when power is lost uXXXXX U...

Страница 14: ...20 i 0 20 E 1 5 E 0 5 or E 0 10 LiNEAR or S9RT PRESS FRONT PANEL OPERATIONS Press to RESET in operating mode Press to ENTER in pro gramming mode Press to view or change Preset A Press to view or chan...

Страница 15: ...toggle between choices press the RST ENTERkeytoenterthedisplayed choice dur A the duration of time 0 01 to 599 99sec thatoutputAwillremainon or energized When durAis displayed hit any key to view or...

Страница 16: ...G or LC ALL or LC ALL or CoDE Press any key to view or change the lock code PRESS This section of the menu is used to set up important operating variables RDEC rate decimal location Press the key unde...

Страница 17: ...layed choice Entering a decimal will add resolution to the total i e tdec 100 will be displayed as 100 0 CFDEC Conversion Factor Decimal Press the arrow keys to enter in the desired conversion factor...

Страница 18: ...tevaluerepresentedby the 20 mA end of the 4 20 mA output KeyinthedesiredvalueandpressRST ENTER to enter displayed value Press PRGM to recycle through list choices STEP 5 SETTING OPTIONS THE PROGRAM SE...

Страница 19: ...the displayed value is not the desired preset press the key s under the digit to be changed Keyinthelockcode seeprogramming step 3 by pressing the keys under the digits to be changed Each time a key...

Страница 20: ...ase is incorrect 2 Conversion factor is in correct 3 Total multiplier is incorrect 1 Recheck power wiring 1 Use a different power sup ply or install a surge sup pressor 1 Recheck input wiring 2 Rechec...

Страница 21: ...any questions concerning our warranty repair modi cation or returned goods process please contact your local dis tributor WARRANTY This product is warranted against defects in materials and workmansh...

Страница 22: ...CF Gallons Acre Feet 32 59 1 10 100 1000 0001 001 01 1 AFT Cubic Feet Acre Feet 2295 1 10 100 1000 0001 001 01 1 AFT Liters Liters 10 10 100 100 1000 LTR Cubic Meters 10 1 10 100 1000 1 1 10 100 CM C...

Отзывы: