7
4.8 End of programming
The programming routine
is repeated once more.
The values set until now
can be checked and mod-
ified.
The programming routine
wil be left and all values
set will be stored as new
parameters.
Afterwards the device is
ready for operation.
Electronic
totalizer
and time meter
52U: basic operating mode
1. Description
• 6 digit
totalizer
and time meter with Reset
function
• Red LED display, character height 8 mm
• Display range 0 ... 999 999
• Leading zeros suppression
• Programming via two setting keys on the front
side
• During programming, the display guides the
user with text prompts
• Operation indicator: the decimal point of the
lowest digit blinks while the count is active.
• Time meter operating modes:
– Counting while INP B is inactive “GAtE.Lo”
– Counting while INP B is active “GAtE.hi”
– Count Start/Stop with INP B edge B “Inb.Inb”
• Counting ranges: h; min; s; h.min.s
2. Inputs
INP
A
Dynamic count input for the
totalizer
.
INP
B
Start-/Stop or gate input for time meter
(independent of the input mode)
RESET
Dynamic RESET
input. Linked in parallel to the
red RESET
key.
Sets the counter to zero. Can be
adjusted individually for the
totalizer
and the time
meter.
3. Selection of the displayed value
Pressing the right key allows switching between
the
totalizer
display and the time meter display .
Press the key briefly to display for 2 seconds the
current function (“total” or “time”). If, during this
period of time, the right key is pressed a second
time, the device switches to the next function and
displays a confirmation (“total” or “time”) for 2
seconds. Then, the value of the selected function
is displayed.