11
Time unit: seconds (accu-
racy depending on posi-
tion of the decimal point*)
Time unit: minutes (accu-
racy depending on posi-
tion of the decimal point*)
Time unit: hours (accura-
cy depending on position
of the decimal point*)
Time units:
Hours:Minutes:Seconds
(decimal point setting is
ignored)
4.4 Operating mode
*0, 0.1, 0.01, 0.001 means: time measurement in
0, 0.1, 0.01, 0.001 time units
4.5 Decimal point
The decimal point defines
the resolution of the pro-
grammed time unit.
0
1
0.0 1/10 (0,1)
0.00 1/100 (0,01)
0.000 1/1000 (0,001)
4.7 RESET mode
(time meter 2)
manual reset via the red
RESET key and electrical
reset via the RESET input
no reset (red RESET key
and RESET input locked)
only electrical reset via the
RESET input
only manual reset via the
red RESET key
only electrical reset via the
RESET input
only manual reset via the
red RESET key
4.6 RESET mode
(time meter 1)
manual reset via the red
RESET key and electrical
reset via the RESET input
no reset (red RESET key
and RESET input locked)
Start/Stop via Inp B.
Counting while Inp B
(Gate) not active or open
Start/Stop via Inp B.
Counting while Inp B (Gate)
active (High level with
pnp; Low level with npn)
Count Start/Stop via INP B
(LOW-HIGH edge with
pnp; HIGH-LOW edge
with npn). Every active
edge changes the counter
status.
Count start via INP A,
stop via INP B. (LOW-
HIGH edge with pnp;
HIGH-LOW edge with
npn)
4.3 Input mode
(time meter)