WARNING: 

Read page 2 first

990146

 

09/08/20

Electronic display 

voltage-powered dual 

function counter with 

4 functions 

Model 52U

Содержание 52U

Страница 1: ...WARNING Read page 2 first 990146 09 08 20 Electronic display voltage powered dual function counter with 4 functions Model 52U...

Страница 2: ...ay counter with 2 totalizing ranges see page 5 an electronic totalizer and time meter see page 7 an electronic time meter with 2 time ranges see page 10 2 Setting of the operating parameters a Press b...

Страница 3: ...d the latest values set remaining active They can now be checked again or modified Electronic totalizer and frequency meter 52U basic operating mode 1 Description 6 digit totalizer and frequency meter...

Страница 4: ...ng for UB 4 2 Switching on the 30 Hz filter INP A 30 Hz filter off fmax It can be set from 00 0001 up to 99 9999 The decimal point is set to 4 decimal places 0 is not accepted 30 Hzfilter on 4 3 Multi...

Страница 5: ...ng via two setting keys on the front side During programming the display guides the user with text prompts 2 Inputs INP A Dynamic count input Counter 1 and Counter 2 RESET Dynamic RESET input Linked i...

Страница 6: ...does not affect counting 0 no decimal place 0 0 one decimal place 0 00 two decimal places 0 000 three decimal places 4 5 Decimal point 4 6 RESET mode totalizer 1 manual reset via the red RESET key and...

Страница 7: ...operating modes Counting while INP B is inactive GAtE Lo Counting while INP B is active GAtE hi Count Start Stop with INP B edge B Inb Inb Counting ranges h min s h min s 2 Inputs INP A Dynamic count...

Страница 8: ...decimal places 0 is not accepted 4 4 Dividing factor totalizer The decimal point defines the way of displaying the count values It does not affect counting 0 no decimal place 0 0 one decimal place 0 0...

Страница 9: ...The decimal point defines the resolution of the pro grammed time unit 0 1 0 0 1 10 0 1 0 00 1 100 0 01 0 000 1 1000 0 001 4 11 End of programming The programming routine is repeated once more The val...

Страница 10: ...Can be adjusted individually for Counter 1 and Counter 2 3 Selection of the displayed value Pressing the right key allows switching between the display of time meter 1 and the display of time meter 2...

Страница 11: ...ectrical reset via the RESET input no reset red RESET key and RESET input locked only electrical reset via the RESET input only manual reset via the red RESET key only electrical reset via the RESET i...

Страница 12: ...2 Start InpB InpB and Inp B connected with Inp A at maximum frequency square wave pulses 1 1 Frequency measurement Accuracy 0 1 Measuring principle 38 Hz period measurement 38 Hz gating time measureme...

Страница 13: ...nel cut out 50 x 25 mm 1 Bezel for clip mounting panel cut out 50 x 25 mm 1 Seal 1 Operating instructions 6 Terminal assignment 8 Dimensions 1 10 30 V DC 2 0 V GND 3 INP A 4 INP B 5 Reset Panel cut ou...

Страница 14: ...KESSLER ELLIS PRODUCTS 10 Industrial Way East Eatontown NJ 07724 800 631 2165 732 649 7100 Fax 732 649 7099 KEP com...