5
4.12 End of programming
The programming routine
is repeated once more.
The values set until now
can be checked and mod-
ified.
The programming routine
wil be left and all values
set will be stored as new
parameters.
Afterwards the device is
ready for operation.
4.10 Display mode
(frequency meter)
Value conversion and
display in 1/s
Value conversion and
display in 1/min
4.11 Max. time to wait until “0” is displayed
(frequency meter)
This parameter indicates, how long it takes, when
measuring is active, until „0“ is displayed.
Max. time to wait 00.1 s
(min. value)
Max. time to wait 99.9 s
Electronic display counter
with 2
totalizing
ranges
52U: basic operating mode
1. Description
• 6-digit dislay counter with Reset function
• Red LED display, character height 8 mm
• Display range 0 ... 999 999
• Leading zeros suppression
• Programming via two setting keys on the front
side
• During programming, the display guides the
user with text prompts
2.
Inputs
INP
A
Dynamic count input Counter 1 and Counter 2.
RESET
Dynamic RESET
input. Linked in parallel to the
red RESET
key.
Sets the counter to zero. Can be
adjusted individually for Counter 1 and Counter 2.
3.
Selection of the displayed value
Pressing the right key allows switching between
the display of
totalizer
1 and the display of
totalizer
2. Press the key briefly to display for 2
sec-onds the current function (“total1” or “total2”).
If,
during this period of time, the right key is
pressed
a second time, the device switches to the
next
function and displays a confirmation (“total1”
or
“total2”) for 2 seconds. Then, the value of the
selected function is displayed.
4.
Programming routine
The programmable parameters of the device are
described below, in the order in which they can
be set. The device is fully programmed after one
pass of the routine.
The first values stated correspond to the factory
settings