TM-271A/271E
26
2. Squelch
1) CH : RX low (Wide)
SSG
ANT
Encoder
Adjust to open the squelch
tight
CH : RX center (Wide/Narrow)
Oscilloscope
EXT. SP
knob
CH : RX high (Wide)
AF V.M
2) SSG output
Distortion meter
: –115dBm (0.4
µ
V) (Wide/Narrow)
Mod : 1kHz
Dev :
±
3.0kHz (Wide)
Dev :
±
1.5kHz (Narrow)
3. Squelch
1) CH : RX low (Wide)
open
CH : RX center (Wide/Narrow)
CH : RX high (Wide)
2) SSG output
: –125dBm (0.126
µ
V) (Wide/Narrow)
Mod : 1kHz
Dev :
±
3.0kHz (Wide)
Dev :
±
1.5kHz (Narrow)
4. RSSI
1) CH : RX center (Wide)
Push
RSSI value writing is per-
writing
2) SSG output : –53dBm (501
µ
V)
encoder
formed by the “Squelch
Mod : 1kHz
knob
open” item (center wide).
Dev :
±
3.0kHz
SSG output level is changed
and adjusted after SQ
adjustment.
This adjustment should not
turn the encoder.
5. S-meter
1) CH : RX center (Wide)
S1
2) SSG output : –118dBm (0.28
µ
V)
Mod : 1kHz
Dev :
±
3.0kHz
6. S-meter
1) CH : RX center (Wide)
full scale
2) SSG output : –96dBm (3.54
µ
V)
Mod : 1kHz
Dev :
±
3.0kHz
Item
Condition
Test equipment
Terminal
Parts
Method
Specifications/
Remarks
Measurement
Adjustment
ADJUSTMENT