TM-271A/271E
40
LEVEL DIAGRAM
To make
G2
Q351
3
IC201
IC203
Q353
XF1
7
IC202
IC202
BPF
BPF
6
8
Q406
ANT
X54-345
G2
9
1
To make measurements in the RF section, connect the RF level meter.
In the RF section, use a 0.01
µ
F coupling capacitor.
(The display shows the SSG input value required to obtain 12dB SINA
1
G1
2
2
S
Q352
10
Display
Unit
D
IC161
TX-RX U
MIC
To make measurements in the AF section, connect the AC level meter.
AG is set so that MIC input becomes 3kHz/1.5kHz (Wide/Narrow) DEV at 1kHz MOD.
D
CF1
/CF2
450kHz
7
IC203
TX-RX Unit
S
IC301
5
49.95MHz
9
IC201
G1
20
1
Center Frequency
W : –124.0dBm
N : –123.5dBm
W : –119.5dBm
N : –119.0dBm
W : –104.7dBm
N : –103.7dBm
W : –103.9dBm
N : –103.4dBm
W : 0.75Vrms
N : 0.36Vrms
W : 0.30Vrms
N : 0.18Vrms
W : –112.3dBm
N : –111.5dBm
W : –92.1dBm
N : –90.7dBm
W : –77.6dBm
N : –74.2dBm
W/N
5.0mVrms (2.0mVrms for E-type)
W/N
0.12Vrms
W/N
1.40Vrms
W/N
1.16Vrms
W/N
1.26Vrms
W/N
1.04Vrms
Receiver Section
Transmitter Section