TKR-D710
61
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
18. Test Tone
Deviation
adjust
[Analog
Wide]
FPU Test mode
1) Adjust Item: [Test Tone De-
viation (Analog Wide)]
Connect the Deviation Meter
to the TX ANT end via the ATT.
Deviation Meter setting
LPF: 15kHz
HPF: OFF
De-emphasis: OFF
Press [Transmit] button.
Deviation
meter
Oscilloscope
Rear
TX ANT
PC
ADJ
3.0kHz Deviation
±0.1kHz
Press [Apply] button to store
the adjustment value.
19. Test Tone
Deviation
adjust
[Analog
Nar-
row]
FPU Test mode
1) Adjust Item: [Test Tone De-
viation (Analog Narrow)]
Connect the Deviation Meter
to the TX ANT end via the ATT.
Deviation Meter setting
LPF: 15kHz
HPF: OFF
De-emphasis: OFF
Press [Transmit] button.
1.5kHz Deviation
±0.05kHz
Press [Apply] button to store
the adjustment value.
20. CW ID
Deviation
adjust
[Analog
Wide]
FPU Test mode
1) Adjust Item: [CW ID Devia-
tion (Analog Wide)]
Connect the Deviation Meter
to the TX ANT end via the ATT.
Deviation Meter setting
LPF: 15kHz
HPF: OFF
De-emphasis: OFF
Press [Transmit] button.
2.0kHz Deviation
±0.1kHz
Press [Apply] button to store
the adjustment value.
21. CW ID
Deviation
adjust
[Analog
Nar-
row]
FPU Test mode
1) Adjust Item: [CW ID Devia-
tion (Analog Narrow)]
Connect the Deviation Meter
to the TX ANT end via the ATT.
Deviation Meter setting
LPF: 15kHz
HPF: OFF
De-emphasis: OFF
Press [Transmit] button.
1.0kHz Deviation
±0.05kHz
Press [Apply] button to store
the adjustment value.
22. Courtesy
Tone Devia-
tion adjust
[Analog
Wide]
FPU Test mode
1) Adjust Item: [Courtesy Tone
Deviation (Analog Wide)]
Connect the Deviation Meter
to the TX ANT end via the ATT.
Deviation Meter setting
LPF: 15kHz
HPF: OFF
De-emphasis: OFF
Press [Transmit] button.
1.0kHz Deviation
±0.05kHz
Press [Apply] button to store
the adjustment value.
23. Courtesy
Tone Devia-
tion adjust
[Analog
Nar-
row]
FPU Test mode
1) Adjust Item: [Courtesy Tone
Deviation (Analog Narrow)]
Connect the Deviation Meter
to the TX ANT end via the ATT.
Deviation Meter setting
LPF: 15kHz
HPF: OFF
De-emphasis: OFF
Press [Transmit] button.
0.5kHz Deviation
±0.05kHz
Press [Apply] button to store
the adjustment value.