TK-361SA
25
LEVEL DIAGRAM
Receiver Section
T
ransmitter Section
RF (Center Frequency)
FM IF
SYSTEM
AQUA-L
AQUA-L
IC302
500mW
C330
IC301
C329
IC201
C219
C224
XF201
C241
C266
C158
L224
L228
L211
Q205
Q204
IC301
C60
VCO
PLL
C78
Q9
C87
D101
RXLO
C107
Q101
C112
Q102
Q103
C158
D202
MIC
SP
–119.5dBm
–119.5dBm
–120.0dBm
–104.0dBm
–110.0dBm
–104.0dBm
290mV
30mV
16mVrms
13.76mVrms
–1.0dBm
16.3dBm
32.8dBm
2.0W
1.8dBm
IF1 (38.85MHz)
AF (1kHz)
AF (1kHz)
RF (Center Frequency)
L224
Q203
IF2 (450kHz)
T
o
make measurements in the AF section, connect the AC level meter
. (ANT input: –53dBm, 1kHz FM, 1.5kHz DEV)
In the RF section,use 1000pF coupling capacitor
. (The display shows the SSG input value required to obtain 12dB SINAD without L
ocal Level.)
AG is set to the MIC Input becomes 1.5kHz DEV at 1.5kHz MOD.
T
o
make measurements in the AF section, connect the AC level meter
.
In the RF section,use 1000pF coupling capacitor
.