TK-361SA
24
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
9. DQT Fine
Deviation
1) Test CH: Low, Center, High
(3 points)
Deviation meter fi lter
LPF: 3kHz
HPF: OFF
PTT: ON
Power
meter
Deviation
meter
Oscillo-
scope
AG
AF VTVM
TX-RX
ANT
Program-
ming
software:
KPG-88D
(M2)
0.40kHz
±40Hz
Receiver Section
Item
Condition
Measurement
Adjustment
Specifi cations / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
1. BPF wave
adjust
1) Center frequency
Spectrum analyzer setting
Center frequency: 460MHz
Span: 200MHz
RBW: 100kHz
VBW: 10kHz
ATT: 5dB
2) High-edge frequency
Sepctrum analyzer setting
Center frequency: 470MHz
3) Low-edge frequency
Sepctrum analyzer setting
Center frequency: 450MHz
Spectrum
analyzer
TX-RX
ANT
BPF
Program-
ming
software:
KPG-88D
(M2)
Adjust the wave-
form as shown to
the below.
2. Sensitivity
1) Test CH: Low, Center, High
SSG output: –116dBm (0.35µV)
SSG MOD: 1.5kHz
SSG
DVM
Oscillo-
scope
AF VTVM
ANT
SP/MIC
Check
12dB SINAD or more
3. Squelch
(Open)
1) Test CH: Low, Center, High
SSG output: –122dBm (0.18µV)
SSG MOD: 1.5kHz
Program-
ming
software:
KPG-88D
(M2)
Write
Squelch open
4. Squelch
(Tight)
1) Test CH: Low, Center, High
SSG output: –116dBm (0.35µV)
SSG MOD: 1.5kHz
5. Battery
Warning
Level
1) BATT terminal voltage: 5.9V
DVM
TX-RX
ANT
BATT
terminal
Write
BATT terminal voltage: 5.9V
REF -50.0 dBm
CENTER 460.0 MHz
∗
RBW 100 kHz
∗
VBW 10 kHz
5dB/
A_Write Norm B_Blank Norm
CENTER
460.0 MHz
REF -50.0 dBm
CENTER 470.0 MHz
∗
RBW 100 kHz
∗
VBW 10 kHz
∗
SWP 400 ms ATT 5 dB
SPAN 200.0 MHz
∗
SWP 400 ms ATT 5 dB
SPAN 200.0 MHz
5dB/
A_Write Norm B_Blank Norm
CENTER
470.0 MHz
REF -50.0 dBm
CENTER 450.0 MHz
∗
RBW 100 kHz
∗
VBW 10 kHz
∗
SWP 400 ms ATT 5 dB
SPAN 200.0 MHz
5dB/
A_Write Norm B_Blank Norm
CENTER
450.0 MHz