TK-361SA
23
ADJUSTMENT
Common Section
Item
Condition
Measurement
Adjustment
Specifi cations / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
1. Setting
1) BATT terminal voltage: 7.5V
2) SSG standard modulation
MOD: 1kHz, DEV: 1.5kHz
2. VCO lock
voltage RX
1) CH: High
Power
meter
DVM
TX-RX
ANT
CV
TX-RX
TC2
2.3V
±0.1V
2) CH: Low
Check
0.6V or more
3. VCO lock
voltage TX
1) CH: High
PTT: ON
TX-RX
TC1
2.3V
±0.1V
2) CH: Low
PTT: ON
Check
0.6V or more
Transmitter Section
Item
Condition
Measurement
Adjustment
Specifi cations / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
1. Frequency
adjust
1) CH: High
PTT: ON
f. counter
TX-RX
ANT
TX-RX
VR1
High frequency
± 50Hz
2. RF High
Power
1) Test CH: Low, Low’, Center,
High’, High (5 points)
BATT terminal voltage: 7.5V
PTT: ON
Power
meter
Ammeter
Program-
ming
software:
KPG-88D
(M2)
2.0W
±0.1W
Less than 1.2A
3. RF Low
Power
1) Test CH: Low, Low’, Center,
High’, High (5 points)
BATT terminal voltage: 7.5V
PTT: ON
1.0W
±0.1W
Less than 1.0A
4. Max
Deviation
1) Test CH: Low, Center, High
(3 points)
AG: 1kHz/150mV
Deviation meter fi lter
LPF: 15kHz
HPF: OFF
PTT: ON
Power
meter
Deviation
meter
Oscillo-
scope
AG
AF VTVM
TX-RX
ANT
SP/MIC
2.2kHz (According to
the , –)
±50Hz
5. VOX 1
1) Test CH: Center
AG: 1kHz/45mV
6. VOX 10
1) Test CH: Center
AG: 1kHz/3.0mV
7. DQT
Balance
1) Test CH: Low, Center, High
(3 points)
Deviation meter fi lter
LPF: 3kHz
HPF: OFF
PTT: ON
ANT
Make the demodu-
lation wave into
square waves
8. QT Fine
Deviation
1) Test CH: Low, Center, High
(3 points)
Deviation meter fi lter
LPF: 3kHz
HPF: OFF
PTT: ON
0.40kHz
±40Hz