TK-2310R
32
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifications / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
6. DQT
Deviation
[Narrow]
1) TEST CH: Center
Deviation meter filter
LPF: 3kHz
HPF: OFF
PTT: ON
Power
meter
Deviation
meter
Oscilloscope
ANT
FPU
0.35kHz
±40Hz
7. QT
Deviation
[Narrow]
1) TEST CH: Center
Deviation meter filter
LPF: 3kHz
HPF: OFF
PTT: ON
0.35kHz
±40Hz
8. DTMF
Deviation
[Narrow]
1) TEST CH: Center
LPF: 15kHz
HPF: OFF
PTT: ON
1.5kHz
±100Hz
9. MSK
Deviation
[Narrow]
1) TEST CH: Center
Deviation meter filter
LPF: 15kHz
HPF: OFF
PTT: ON
1.5kHz
±100Hz
Receiver Section
Item
Condition
Measurement
Adjustment
Specifications / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
1. Sensitivity
(Semiauto-
matic)
1) TEST CH: Low
SSG otuput : –90dBm
(7.08µV)
SSG MOD: 1.5kHz
SSG
DVM
Oscilloscope
ANT
FPU
Press [Start]
(Auto tuning)
2. Open
Squelch
(5) [Narrow]
1) TEST CH: Low
SSG otuput: –119dBm
(0.25µV)
SSG MOD: 1.5kHz