TK-2310R
31
ADJUSTMENT
Common Section
Item
Condition
Measurement
Adjustment
Specifications / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
1. Setting
1) BATT terminal votage: 7.5V
2) SSG standard modulation
[Narrow]
MOD: 1kHz, DEV: 1.5kHz
2. Receive
Assist
Voltage
1) (Auto tuning)
*Note
DVM
TX-RX CVIN
TX-RX FPU
(3.0V±0.1V)
2) CH: Low
Check
2.5V or more
3. Transmit
Assist
Voltage
1) (Auto tuning)
*Note
TX-RX FPU
(3.0V±0.1V)
2) CH: Low
PTT: ON
Check
2.5V or more
Note: At test mode, click [Tune Assist Voltage] button in test mode dialog box, then start automatic adjustment of Recive/Transmit assist voltage.
Transmitter Section
Item
Condition
Measurement
Adjustment
Specifications / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
1. Frequency
1) TEST CH: Center
PTT: ON
f. counter
ANT
TX-RX FPU
245.600MHz
±50Hz
2. High
Transmit
Power
1) TEST CH: Center
BATT terminal voltage: 7.5V
PTT: ON
Power
meter
Ammeter
FPU
5.0W
±0.1W
2.0A or less
3. Low
Transmit
Power
1) TEST CH: Center
BATT terminal voltage: 7.5V
PTT: ON
1.0W
±0.1W
1.0A or less
4. DQT
Balance
[Narrow] 1
1) TEST CH: Center
Deviation meter filter
LPF: 3kHz
HPF: OFF
PTT: ON
Power
meter
Deviation
meter
Oscilloscope
ANT
Make the demodu-
lation wave into
square waves.
5. Maximum
Deviation
[Narrow]
1) TEST CH: Center
Deviation meter filter
LPF: 15kHz
HPF: OFF
PTT: ON
2.2kHz (According
to the , –)
±80Hz
Note:
FPU AUTO INPUT
1kHz/150mV