TH-K2AT/K2E/K2ET
35
ADJUSTM ENT
1.Setting and
Connect the optional PG-2W
LCD total illumination display
Initial configuration displayed after
resetting
DC cable to the pow er supply.
the full-reset.
DC IN terminal voltage: 13.8V
1) Total illumination display
confirmation
Turn the Transceiver Pow er ON by pressing the pow er sw itch w hile the [F] key is pressed.
While the [F] key is pressed, all LCD segments light.
2) Full-resetting
After confirming that all LCD segments have lighted described in the Step 1 above, release
the [F] key, and then press the [F] key tw ice w hile “ FL.RST?” appears on the display.
2 VCO
After removing 3 screw s fixing
Lock voltage the TX-RX unit (B/3), remove
Check
the TX-RX (B/3) unit from the
CN9 connector of the TX-RX
unit (A/3).
1) Frequency: 136.000M Hz
DVM
TX-RX
LV
Check
0.7V or more
RX
2) Frequency: 173.990M Hz
(A/3)
4.3V or less
TX
TX pow er: Low
1) Frequency: 136.000M Hz
0.7V or more
PTT: ON
2) Frequency: 173.990M Hz
4.3V or less
PTT: ON
After observing the VCO
lock voltage, connect the
TX-RX unit (B/3) to the
original position.
3.TX frequency 1) TX pow er: Low
f. counter
ANT
TX-RX
VR1
145.990M Hz
±150Hz
Adjust
Frequency: 145.990M Hz
(A/3)
PTT: ON
4.Overvoltage
Sw itch to Adjustment mode
w arning
and carry out the operations
reference
for adjustment item A.
voltage
(Refer to page 28)
Adjust/Check 1) LCD display: DC
DC pow er supply
[M ENU]
Write
Frequency: 145.050M Hz
(E, E3)
Frequency: 146.050M Hz
(K, K2, M , M 2)
DC IN terminal voltage: 14.8V
To exit from the Adjustment
M ode, turn the transceiver
pow er OFF and then ON.
2) Frequency: 145.050M Hz
Check
Alarm sound and
(E, E3)
display “ DC ERR”
Frequency: 146.050M Hz
message.
(K, K2, M , M 2)
DC IN terminal voltage: 17.5V
Common Section
Item
Condition
M easurement
Adjustment
Specifications/
Test equipment
Unit
Terminal
Unit
Parts
M ethod
Remarks