Figure 6: Motor Controller and Mount Assembly (Heat Sink on right)

3b. Motor Controller

Check power to motor controller board:

P1 of the motor control board should have 120 VAC

across its two terminals

when the motor controller

is powered

. See Test #3. Replace the motor control

board if connector is broken.

Check link between machine controller and motor

controller:

With the power disconnected

, check connectivity

between P4 of the machine controller and P2 of the

motor controller. Replace upper harness if necessary.

Replace control board if connector is broken.

Check fuse:

With the power disconnected, check for an open

fuse. You may have to scratch away conformal

coating from the bare metal of the fuse before

checking for continuity.

If there is a problem with any component of the motor

control board, replace the entire board.

3c. Wiring and Drive Motor

Check the drive motor windings by removing connectors

P6 from the motor controller board. Check for the

resistance values shown in Table 3. For ground contact,

use a ground screw attached to the top.

If the winding measurements are much higher (tens of

Ohms to infinity) than shown in Table 3, a problem exists

in the motor winding or in the connection between the

control board and the motor. Check the resistance at the

drive motor. Remove the connector at the motor, and

take measurements as shown in Table 4.

TABLE 3

WINDING

RESISTANCE

CONTACTS MEASURED

MAIN to FHOT

3.1 Ohms

P6-2 (RD)

P6-4(WH/BK)

AUX to FHOT

2.8 Ohms

P6-1 (YL)

P6-4(WH/BK)

MAIN to AUX

5.9 Ohms

P6-2 (RD)

P6-1 (YL)

FTC to FHOT

< 0.5 Ohms (short) P6-5 (WH/RD) P6-4(WH/BK)

MAIN to Ground > 1M Ohms (open)

P6-2 (RD)

Ground screw

in top

AUX to Ground > 1M Ohms (open)

P6-1 (YL)

Ground screw

in top

TABLE 4

WINDING

RESISTANCE

MOTOR WINDINGS*

MAIN to FHOT

3.1 Ohms

RD

BK

AUX to FHOT

2.8 Ohms

YL

BK

MAIN to AUX

5.9 Ohms

RD

YL

FTC to FHOT

< 0.5 Ohms (short)

WH

BK

MAIN to Ground > 1M Ohms (open)

RD

GN/BK

AUX to Ground > 1M Ohms (open)

YL

GN/BK

*

Measure resistance directly across the motor windings

where these colored wires enter the motor.

If the resistance is much higher (tens of Ohms to infinity)

than shown in Table 4, replace the drive motor.

If the resistance at the drive motor is correct, there is an

open circuit in the wiring between the motor and control

board. Repair or replace the lower wiring harness.

Содержание Elite 110.2108200

Страница 1: ... an anti static wrist strap Connect wrist strap to green ground connection point or unpainted metal in the appliance OR Touch your finger repeatedly to a green ground connection point or unpainted metal in the appliance Before removing the part from its package touch the anti static bag to a green ground connection point or unpainted metal in the appliance Avoid touching electronic parts or termin...

Страница 2: ...r the display If the motor controller detects an unrecoverable off balance condition the machine controller will shut down and display an ob for off balance The lid switch must be opened at least once before restarting the cycle if this condition occurs Opening the lid will allow the customer to view and redistribute the load Press STOP CANCEL to clear the display Sr signifies a failure of the rel...

Страница 3: ...s at any time all water valves should turn off Press EXPRESS WASH after step 2 below to start draining Press EXPRESS WASH again to turn off pump STEP PRESS TOUCHPAD DISPLAY CONTROL ACTION 1 Key Dance SET DELAY TIME END OF CYCLE SIGNAL SET DELAY TIME END OF CYCLE SIGNAL DIAGNOSTIC TEST INDICATOR The Water Inlet and Dispenser Valve Operating Pressure Switch Test is activated Key Dance must be comple...

Страница 4: ...ivated Key dance must be completed within 5 seconds to be valid 2 WASH RINSE TEMP 00 on the display 3 repeat Cold Water Inlet Valve and Fabric Softener dispenser valve on Cold Cold and Normal above WASH TIME LEDs will turn on 4 WASH TIME Normal LED will turn off and Normal Maximum LED will turn on Fabric softener valve will shut off and Fresh water valve will turn on 5 WASH RINSE TEMP Normal Maxim...

Страница 5: ...t progresses STEP DESCRIPTION OF SEQUENCE DISPLAY In Seconds INLET VALVE Hot or Cold DISPENSER WASH TIME LED LIT PUMP MOTOR ACTION DRIVE MOTOR ACTION DRIVE MOTOR SPEED 1 NUTATE FILL 99 81 COLD FRESH MAX NORM OFF NUTATE 300 2 NUTATE RECIRCULATE 80 61 COLD FAB SOFT NORMAL RECIRCULATE NUTATE 275 3 NUTATE FILL DRAIN 60 41 BOTH BLEACH NORM MIN DRAIN NUTATE 250 4 NUTATE FILL DRAIN 40 21 HOT DETERGENT MI...

Страница 6: ...RLAY TOUCH SCREEN LED ASSEMBLY FRESH VALVE ATC SENSOR P13 P11 2 1 2 8 7 3 5 4 6 TN OR BU OR OR BK WH OR FABRIC SOFTENER VALVE BLEACH VALVE DETERGENT VALVE 3 2 1 OPERATING PRESSURE SWITCH LID SWITCH 3 4 5 TN VT OR 3 2 1 GY WH WH RD T P11 P12 MACHINE CONTROL LOG VALVE BK WH GY GY PK FLOOD PRESSURE SWITCH BU 1 PK 4 3 2 1 P16 3 4 5 2 1 1 2 3 P6 2 3 4 5 RD SHIELD WH BK 1 YL WH RD WH RD BU TN YL WH BU B...

Страница 7: ...m an over fill could indicate a failure to drain WON T NUTATE AT ANY SPEED 1 Check harness connections 2 Drive motor See Test 3 3 Drive mechanism failure WON T SPIN AT ANY SPEED 1 Check harness connections 2 Drive motor See Test 3 3 Drive mechanism failure MOTOR OVERHEATS 1 Drive motor See Test 3 WON T DRAIN 1 Check pump See Spin and Drain Test in Diagnostic Tests section 2 Check pump motor 3 Chec...

Страница 8: ... VAC see Troubleshooting Test 1 the control board has a faulty valve driver Replace the machine control board If the voltage measurements are correct check the individual solenoid valves Unplug the washer and disconnect connector P13 from the control board Check the resistance at contacts shown in the following Table 2 If resistance is outside of range replace the entire log valve assembly TABLE 2...

Страница 9: ...e motor controller board Check for the resistance values shown in Table 3 For ground contact use a ground screw attached to the top If the winding measurements are much higher tens of Ohms to infinity than shown in Table 3 a problem exists in the motor winding or in the connection between the control board and the motor Check the resistance at the drive motor Remove the connector at the motor and ...

Страница 10: ...by pressing the START touchpad Check for the following situations None of the LEDs light up A particular group of LEDs does not light up A single LED does not light up No beep sound is heard No washer function is activated when a particular touchpad is pressed None of the LEDs light up Visually check that connectors P11 and P12 are inserted all the way into the machine controller A particular grou...

Страница 11: ... Switch trip point Press HEAVY DUTY then START to start a cycle Let the unit fill and see if Flood Pressure Switch will trip Check the voltage across pins P and V of the Flood Pressure Switch If 120 VAC is present the water level pressure has opened the switch This should also shut off the water inlet valves and give an FL indication on the 7 segment display If no voltage is present and the water ...

Страница 12: ... both mounting screws into control board and secure to control bracket Plug all connectors into the control board Reconnect ribbon connectors so that the ribbon is wrapped around the two wire GY WH and BK WH leads Plug wire harness snap tie into top of board To remove motor control board Remove all connectors from the control board Remove lock down screw from plastic bracket mounting screw 1 see F...

Отзывы: