DIAGNOSTIC TESTS
Each diagnostic test is activated by performing a “Key
Dance”; pressing certain touchpads in sequence. A key
dance must be completed within 5 seconds in order for a
test to remain active. After performing a Key Dance, the
Diagnostic Test Indicator
will be displayed to verify that
the test has been activated.
■
The control must be in the OFF state before pressing the
touchpad sequence to start each test.
Any
Diagnostic Tests
can be stopped by pressing the
STOP/CANCEL touchpad. Tests will self-terminate after
running for about 3 minutes or less.
TECH SHEET - DO NOT DISCARD
PAGE 3
FOR SERVICE TECHNICIAN'S USE ONLY
PART NO. 3954702 REV. A
Select
Dispenser
Select
Hot/Cold
Inlet Valve
Select Drive
Motor Speed
Select Pump Motor action
Fresh Fill
Fabric Softener
Bleach
Detergent
Hot
water
Nutate150
Spin60
Nutate300
Spin600
Nutate225
Spin250
Nutate300
Spin500
Nutate250
Spin300
Nutate300
Spin800
Nutate275
Spin400
Pump
Drain
Nutate300
Spin500
Pump
Recirc
Cold
water
Key Dance
Cancel ALL diagnostics,
turn off washer
START or
PAUSE drive
motor
Press to set "00”
completing
Key Dance
after
Select Drive
Motor direction
Nutate or Spin
Key Dance must be completed
before proceeding with test
Figure 1: Manual Diagnostics Description
WATER INLET AND DISPENSER VALVE OPERATING PS TEST
Refer to Figure 1. If Operating Pressure Switch trips at any time, all water valves should turn off. Press EXPRESS WASH after step 2 below
to start draining. Press EXPRESS WASH again to turn off pump.
STEP #
PRESS TOUCHPAD
DISPLAY
CONTROL ACTION
1
Key Dance:
SET DELAY TIME
⇒
END OF CYCLE SIGNAL
⇒
SET DELAY TIME
⇒
END OF CYCLE SIGNAL
DIAGNOSTIC TEST INDICATOR
The Water Inlet and Dispenser Valve Operating Pressure Switch Test is
activated. Key Dance must be completed within 5 seconds to be valid.
2
WASH/RINSE
TEMP
“00” on the display
3
repeat
Cold Water Inlet Valve and Fabric Softener dispenser valve on.
Cold/Cold and Normal (above WASH TIME) LEDs will turn on.
4
WASH TIME
Normal LED will turn off and Normal-Maximum LED will turn on.
Fabric softener valve will shut off and Fresh water valve will turn on.
5
repeat
Normal-Maximum LED will turn off and Minimum will turn on.
Fresh water valve will turn off and Detergent dispenser valve will turn on.
6
repeat
Minimum LED will turn off and Minimum-Normal LED will turn on.
Detergent valve will turn off and Bleach valve will turn on.
7
repeat
This key press turns off the Bleach and turns on the Fabric Softener.
8
WASH/RINSE
TEMP
Cold/Cold LED turns off and Hot/Cold LED turns on.
Cold inlet valve turns off and Hot inlet valve turns on.
9
repeat
Both hot and cold inlet valves turn on.
10
repeat
All valves turn off.
1. Press STOP/CANCEL
to turn unit off.
2. Repeat steps 1 and
2 of this test.
3. Press EXPRESS WASH.
4. Press EXPRESS WASH
again to turn off the pump.
If Operating Pressure Switch trips at any time, all water valves should turn off. To start draining: